Description:
A Lexan polycarbonate detector exposed on the exterior of Skylab-3 for 73 days during a solar quiet period was used to study the relative abundances of calcium to nickel ions in low energy cosmic rays of 50 to 250 MeV/N. The method of charge identification is based on the measurement of conelength (L) and residual range (R) of these particles in various Lexan sheets. Since more than one cone (sometimes as many as five) is observed and is measured, the charge accuracy becomes precise and accurate. The ratio of (calcium to manganese) to (iron and cobalt) obtained at three energy intervals of 50 to 80, 80 to 150, 150 to 250 and 50 to 250 MeV/N are 7.6 plus or minus 3.8, 2.7 plus or minus 0.8, 1.4 plus or minus 0.6 and 3.3 plus or minus 0.7 respectively. These data thus indicate a large increase of this ratio with decreasing energy. The origin of this strong energy dependence is not understood at present.