Experimental studies are being conducted at JPL to identify long life, high area power density electrodes for AMTEC. Power versus time measurements are being made in a demountable electrode test cell and, for longer term experiments, a self-contained recirculating cell. The experimental apparatus and procedures are described in detail. The results show that thin film molybdenum electrodes can be designed to produce power near 0.5 W/sq cm for over two hundred hours. Also, platinum/tungsten electrodes exhibit power densities that are stable near 0.5 W/sq cm. If the performance of these electrodes is verified for longer periods (thousands of hours), then practical AMTEC systems will be possible.