ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Low concentrations of betaxolol in blood plasma and physiological buffers were determined by selected ion monitoring of the intense m/z 72 fragment [CH2=NH—CH(CH3)2]+ formed by electron impact ionization of the O-trimethylsilyl derivative. At a mass spectrometric resolution of 3000, fewer potentially interfering peaks were seen than at low resolution. There remained a chemical interference, corresponding to 100 pg/sample, which arose during treatment of the samples. This method is more sensitive than previous ones, but it is restricted to situations where the specificity can be controlled. When the m/z 72 fragment was mass-shifted by using betaxolol appropriately labelled with deuterium or 13C, both the interference and the baseline noise were greatly reduced; concentrations of labelled betaxolol as low as 10-20 pg/sample can be determined with little difficulty.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0721-3115
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An experimental program is described in which the capacitor-discharge initiation characteristics of a detonator containing a vacuum-deposited thin-film chromium bridge were studied. The objective of the effort was to define the conditions that would result in overall function times of 10 μs or less. The threshold initiation energy of the detonator was in the range of 11.5 mJ-20.0 mJ. Consistent performance was obtained from a firing energy of 54 mJ, which was achieved by a 5-μF capacitor charged to 147 V. Under these conditions, the average overall function time was 4.2 μs, with a standard deviation of 0.2 μs. Other tests showed that at higher capacitances and lower voltages the function time increased substantially and became more nonreproducible, even though the stored energy was considerably above the threshold value.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...