ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: methotrexate ; osteosarcoma ; high parenteral dose ; pharmacokinetics ; drug monitoring ; computer prediction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Methotrexate (MTX) in serum was measured by RIA in 12 cancer patients receiving high doses of MTX (2 to 8 g/m2) in 6 hour infusions 69 treatments were studied. The peak serum level was proportional to the dose administered and was always greater than 10−4 M. 2 elimination phases were seen: the first had a mean half-life of 2.36 h and the second a mean half-life of 16.14 h. 24 hours after beginning the infusions there were very large variations in individual serum concentrations of MTX, from 2.4 10−6 M to 1.9 10−5 M by 24 h after 8 g/m2. To control these variations, a mathematical model for prediction of the individual pharmacokinetic pattern of a 6 hour-infusion of high-dose MTX by kinetic analysis of a low-test dose is proposed. A program was created for an Apple III computer using toxic and therapeutic serum levels of MTX selected by the clinician. The computer program is adaptable to any infused substance for variable infusion times, thus introducing new advances over existing methods.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 20 (1986), S. 1347-1357 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ultra low temperature isotropic (ULTI) carbon-coated polyester suture material was evaluated histologically and mechanically in dogs. These results were compared to those obtainedfor uncoated polyester and polybutylate coated polyester. The suture materials were used in therepair of the surgically incised medical collateral ligament and subcutaneous tissues to evaluate the potential of the carbon-coated system for ligamentous repairs. Following surgery, the dogs were sacrificed at periods of 1-48 weeks postoperatively for evaluation of tissue biocompatibility and mechanical strength of the materials. The polybutylate-coated polyester suture broke at lower force levels than did comparable sizes of uncoated or carbon-coated polyester. All three types showed a high retention (〉98%) of mechanical strength at 48weeks, often exhibiting an increase in tensile strength due to tissue ingrowth. The histologic response to carbon-coated polyester was equal to or better than the response to either the uncoated polyester or polybutylate-coated polyester. A greater degree of tissue growth into the carbon-coated material was evident at most time periods following an initial acute inflammatory response which was also present in the other materials.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...