ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (21)
  • Beta vulgaris  (3)
  • 42.75
  • Superfluidity and superconductivity
  • 1985-1989  (24)
Collection
Publisher
Years
Year
  • 1
    ISSN: 1432-2242
    Keywords: Beta vulgaris ; Sugar beet ; Beta lomatogona ; Beta procumbens ; Interspecific hybrid ; Isozyme polymorphism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary A tetraploid (2n=36) interspecific hybrid was obtained involving three species belonging to three different sections of Beta. The hybrid was highly sterile and did not show apomixis. At meiosis, up to nine bivalents were observed, most probably resulting from autosyndesis of the chromosomes of Beta lomatogona. For nine isozyme systems, individual enzyme expression was investigated in the parental species and in the hybrids. No silencing of genes or genomes was observed. In the case of some polymeric enzymes interspecific heteropolymers could be detected.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Theoretical and applied genetics 76 (1988), S. 656-664 
    ISSN: 1432-2242
    Keywords: Beta vulgaris ; Beta procumbens ; Alien monosomic additions ; Plant development in vivo ; Development in vitro
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary Alien monosomic additions in beet (Beta vulgaris), each carrying one of the nine chromosomes of B. procumbens, were grown in vivo and in vitro to study the effect of the alien chromosomes on plant development. All additional chromosomes caused a reduction of the growth rate in vivo, which, in one case was so strong that some of the plants died as seedlings. In general, the morphological plant characteristics were not very useful to distinguish the addition types; this could have been the results of the wide variation in the recipient parent. However, some developmental characteristics proved to be highly chromosome-specific; for plants in vivo this was annuality, in combination with early or late flowering. If grown in vitro, chromosome specificity was observed for growth type (rosette or elongated stem), occurrence and rate of vitrification, occurrence and morphology of wound callus, formation of additional meristems on the midribs of leaves, formation of roots and a specific reaction to benzylaminopurine (BAP) the medium. Two chromosome types of B. procumbens caused resistance to the beet cyst nematode.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Theoretical and applied genetics 76 (1988), S. 577-586 
    ISSN: 1432-2242
    Keywords: Beta vulgaris ; Beta procumbens ; Alien monosomic additions ; Isozyme markers ; Chromosome identification
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary Eleven isozyme systems were used to identify the extra chromosomes, originating from Beta procumbens, in progenies of 33 monosomic additions in beet (B. vulgaris). Nine groups of monosomic additions could be distinguished, representing the nine different chromosome types of B. procumbens.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 515-517 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary column ; Electron impact mass spectrometry ; Linear retention indices ; Dinitrofluoranthenes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper reports the retention indices of eighteen of the possible twenty-five dinitrofluoranthene isomers.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Detection limits ; Trace analysis ; Narrow bore columns ; Wide bore columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The need for faster and more efficient separations of complex mixtures of organic compounds by gas chromatography has led to the development of small inner diameter open tubular columns. Owing to their decreased plate height, extremely narrow peaks are obtained. When differently sized columns with equal plate numbers are compared, injection of a fixed amount of a solute will give the highest detector signals for the smallest bore columns. When P is defined as the ratio of the column inlet and outlet pressures, it can be seen from theory that under normalized chromatographic conditions the minimum detectable amount (Qº) for a mass flow sensitive detector increases proportionally to the square of the column diameter for P = 1. In the situation of greater interest in the practice of open tubular gas chromatography where P is large, a linear relationship is derived between Qº and the column diameter.It is a widespread misunderstanding, however, that narrow bore capillary columns should be used for this reason in trace analysis. If a fixed relative contribution of the injection band width to the overall peak variance is allowed, a decreased plate height drastically restricts the maximum sample volume to be injected. It is shown that the minimum analyte concentration in the injected sample (Cº) is inversely proportional to the column inner diameter when a mass flow sensitive detector is used. For actual concentrations less than Cº, sample preconcentration is required. The effect of peak resolution and selectivity of the stationary phase in relation to Cº and Qº will be discussed as well. The validity of the given theory is experimentally investigated. Minimum analyte concentrations and minimum detectable amounts are compared using columns with different inner diameter.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 106-110 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Tandem capillaries ; Charcoal trapping ; Soil fumigants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Soil fumigants, like 1,3-dichloropropene and metham-sodium (forming methyl isothiocyanate) diffuse into the atmosphere, thus presenting a hazard to people in the surroundings. A method is described in which a large volume (50 μl) of extractant, used to desorb the compounds from charcoal, is injected into a GC, equipped with two capillary columns. By way of Deans switching, the solvent is separated from the compounds of interest. Modification of a GC sampler makes unattended analyses possible.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: Capillary GC ; Coupled LC-GC ; Large injection volumes ; Trace analysis ; Aqueous samples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes the design of a new, versatile, and low-cost on-line LC-GC interface that allows the fast and reliable introduction of large sample volumes onto a capillary GC column. The sample introduction procedure consists successively of: evaporation of the entire sample (LC fraction), selective removal of the solvent and simultaneously cold-trapping of the solutes, splitless transfer of the solutes to the GC column, on-column focusing, GC separation and detection. Quantitative and qualitative aspects of various experimental parameters are evaluated and optimum conditions are reported. The applicability of the method is demonstrated on a synthetic aqueous sample of chlorinated pesticides.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0935-6304
    Keywords: Coupling LC/GC ; Retention gap ; Polychlorinated biphenyls ; Sediment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90-100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Detectability ; Thick films ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: For a typical narrow bore (50 μm) and wide bore (320 μm) capillary column the effects of increased stationary phase film thickness (df) on the minimum detectable amount, Qo, as well as on the minimum analyte concentration, Co, are described. In treating the effect of an increased film thickness, two approaches can be followed; either the separation temperature is kept constant, resulting in larger values of the capacity ratio, k, or the column temperature is increased such as to keep k constant. For normalized chromatographic conditions the effects of both approaches on the minimum plate height, optimum carrier gas velocity, and required plate number are described, finally yielding expressions for Qo and Co for both mass flow and concentration sensitive detectors. At constant temperature, Co always increases with the film thickness for mass flow sensitive detectors (e.g. FID). Wide bore thin film columns offer the lowest value of Co attainable. For concentration sensitive detectors (e.g. TCD), Co is affected neither by column diameter nor by film thickness. The Qo-df plot for constant temperature shows a minimum, suggesting an optimum film thickness for mass flow sensitive as well as concentration sensitive detectors. The corresponding capacity ratio has a value between 0.5 and 1.5. At elevated temperatures (k constant) in combination with mass flow sensitive detectors, again an optimum film thickness exists, corresponding to a minimum value of Co. For constant capacity ratio Qo always increases with the film thickness for both types of detectors. As indicated above, in some situations the lowest values of Co and Qo are obtained at an increased film thickness, the effect being marginal. As an initial guideline, for the daily practice of capillary gas chromatography with respect to minimum values of Co and Qo, the use of thin film columns is to be preferred.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 462-470 
    ISSN: 0935-6304
    Keywords: Grob and splitless injection ; Injection techniques, capillary GC ; Splitless injection ; PTV splitless injection ; Matrix effexts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Kurt Grob introduced splitless injection in 1969. He elaborated most of the working guidelines including the techniques required for reconcentrating the broad intial bands, i.e. the solvent effects and cold trapping. He also designed a vaporizing injector suited for splitless injection. Nevertheless, splitless injection is still often carried out using inappropriate conditions, and many of today's vaporizing injectors are not suited for splitless injection. No autosampler is available that introduces the sample at the appropriate position. Conventional splitless injection is compared to PTV splitless injection for the range of samples that cannot be handled by the anyway superior oncolumn injection, i.e. sample with high loads of involatile byproducts. There is a clear preference for PTV splitless injection as matrix effects observed in conventional splitless injection were found to be substantially reduced or even eliminated.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...