ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (2)
  • 1-Alkyl-5,10-dihydro-4,10a-diphenyl-pyrrolidino[2,3-b][1,5]-benzodiazepin-2,3-dione  (1)
  • 1985-1989  (3)
  • 1935-1939
Collection
Keywords
Publisher
Years
Year
  • 1
    ISSN: 1434-4475
    Keywords: 3-Benzoyl-2-phenylthieno[2,3-b]quinoxaline ; 1-Alkyl-5,10-dihydro-4,10a-diphenyl-pyrrolidino[2,3-b][1,5]-benzodiazepin-2,3-dione ; X-ray structure analysis ; 13C NMR spectroscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract 4-Benzoyl-5-phenylthiophene-2,3-dione (1) reacts witho-phenylendiamine to give the quinoxaline derivative2 which cyclizes either to the furo[2,3-b]quinoxaline4 or to the thieno[2,3-b]quinoxaline5 depending on the reaction conditions. On the other hand, the pyrrol-2,3-diones6 ando-phenylendiamine combine yielding the pyrrolidino[2,3-b][1,5]benzodiazepine derivatives7. The structures of all compounds were confirmed by IR and13C NMR spectroscopic measurements based on X-ray structure determinations of4/5 (mixed crystal) as well as7 b.4/5 crystallize triclinically in the space group P1 (Nr. 2) with two molecules per cell, while7 b crystallizes monoclinically in space group P21/a (Nr. 14) with four molecules7 b and four moleculesDMSO per cell. The reaction pathways leading to the compounds2,4,5, and7 are briefly discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: The primary UV radiometric calibration standards of the Atomic and Plasma Radiation Division of the NBS are the hydrogen arc and the blackbody line arc. The secondary standards are the argon mini- and maxiarcs, and the deuterium arc lamp. Calibration methods involving both spectral radiance and irradiance, as well as the evaluation of their uncertainties, are discussed. Attention is given to the establishment of an irradiance scale, and the absolute spectral irradiance, measured as a function of wavelength, at a 50-cm distance from the field aperture for five different continuum sources.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Research (ISSN 0160-1741); 93; 21-39
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-27
    Description: The far-UV and XUV detector calibration services at NBS, the properties of the detectors, and the spectrometer calibration facilities at the Synchrotron Ultraviolet Radiation Facility (SURF II) at NBS are described. The method used to calibrate the quantum efficiency of windowless photodiode detectors in the ionization chamber, and the facilities for calibrating photodiodes at various wavelengths are discussed. The cathode and anode of the windowless photodiodes and their operation are examined. Consideration is given to the calculation of spectral irradiance from SURF II; the two stations of the spectrometer facility; the large spectrometer calibration chamber; and sources of error in flux determinations for SURF II.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: X-ray calibration: Techniques, sources, and detectors; Aug. 19, 20, 1986; San Diego, C A; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...