ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2,535)
  • Polymer and Materials Science  (1,966)
  • Chemical Engineering  (483)
  • Physical Chemistry
  • 1985-1989  (1,548)
  • 1975-1979  (987)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 36 (1988), S. 1433-1441 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Telechelic prepolymers of butadiene with aliphatic isocyanate end-groups were prepared by the solution polymerization of butadiene under free radical initiation. 4,4′-Azobis (4-cyanopentanoyl azide) was used as the initiator. Liquid prepolymers were obtained with molecular weights of 1450 to 6000 and functionalities 1.9 to 2.2. The prepolymers were characterized by their number-average molecular weight, isocyanate content, functionality, infrared, and nuclear magnetic resonance spectra and microstructure. The storage stability of the prepolymers was checked and they were found to be quite stable under ambient conditions. Isocyanate-terminated polybutadienes were reacted with N,N-dimethylamino ethanol and t-butyl hydroperoxide to obtain useful dimethylamino-terminated and peroxycarbamate-terminated prepolymers, respectively.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 36 (1988), S. 837-858 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: An extensive study on the turbulent drag reduction caused by the various mixtures of polyacrylamide, purified guargum, xanthangum, and their graft copolymers has been conducted at low concentrations and Re = 14,000 using a turbulent flow rheometer. It has been found in most of the cases that the drag reduction caused by mixtures shows a positive deviation from the linearly additive straight line. This effect is more prominent when the drag reduction caused by both the constituents differ appreciably. In most of the cases, the drag reduction caused by the mixtures is higher than the DR caused by either of the constituent polymers; however, the drag reduction caused by the mixture is less than the sum of the drag reduction caused by both the constituents at their respective concentration in the mixture. It has also been noticed that there is no evidence of synergism in these mixtures at low concentrations.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 26 (1988), S. 953-958 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 34 (1988), S. 781-789 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Experimental measurements are reported of oil-water flows in a 20 cm ID pipe at mean velocities between 2.7 and 35 cm/s, at deviation angles θ from vertical between 0 and 65°, and at water flow rate fractions between 30 and 100%. The distribution of the water volume fraction αw across a pipe section is obtained using local high-frequency probes. The mean water volume fraction in the section and the slip velocity Vs between oil and water are also determined. High Vs values (up to 50 cm/s) are measured at large deviation angles; they are associated with oil droplet swarms or continuous oil phase zones. Both αw profiles and Vs values depend only on the mean water volume fraction and not on the total flow rate Qt in the range investigated. At low oil volume fractions αo, all droplets are concentrated close to the upper side of the pipe. At larger αo values, a slower linear variation of αw with the distance y from the axis is measured. A model is suggested relating the slope ∂αw/∂y in a vertical plane to the existence of internal density waves in the stratified mixture.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 885-890 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1172-1176 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: An important function of an optical fiber coating is to prevent optical losses due to microbending induced by lateral forces on the fiber. To protect the fiber over a wide temperature range the modulus of the primary and the secondary coating should be low and high, respectively, and temperature independent. However, selecting the most appropriate organic coating materials introduces a new source of optical losses. Since the linear thermal expansion coefficients of silica and the organic coatings differ by about two orders of magnitude, thermal, fluctuations will cause axial stresses. Cooling may then induce bending or buckling of the glass fiber in the soft primary coating, resulting in increased transmission losses. This effect is especially pronounced when a high-modulus secondary coating is selected with a glass transition temperature above 80°C. For this type of coating the difference in radial shrinkage between the buffer and the top coating during cooling from the curing temperature becomes important. The influence of primary coating thickness is discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The “condensed” counterions which characterize high-charge-density polyelectrolyte solutions can be analyzed into two subpopulations: (1) site-bound counterions and (2) atmospherically entrapped counterions. The distinction is achieved experimentally by combining the data from self-diffusion coefficient or electrical mobility measurements, which give the amount of “condensed” ions, and those from nmr, chemical shift measurements, which indicate the amount of site-bound ions. In the case of a solution of chondroitin sulfate with excess Co++ counterions, it can be estimated that 20% of the structural charge of the polyion is neutralized by site-bound, dehydrated, condensed counterions, while a further 30% is neutralized by atmospherically entrapped, hydrated counterions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 37 (1989), S. 3057-3060 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 660-667 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The operation of a twin screw extruder processing a powder or granular solid is reviewed. The operating variables of screw speed and barrel temperature profile interact with a number of design parameters -  screw design, die geometry, feed zone geometry and with the material properties, in determining machine performance. The factors that determine output and pressure development are specified in a sequence of block diagrams. The dynamic response of an operating machine to disturbances in the steady state conditions is explained in the light of the established relationships and interpreted in conventional control theory terms. Attention is drawn to the importance of mixing in the chambers formed by the screw channels and of the residence time distribution in determining the quality of the final product.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 23 (1989), S. 705-718 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The peritoneal cavity is a convenient site for implantation of encapsulated hormonesecreting tissue. However, host tissue organization around such implants may affect solute exchange and viability of the encapsulated tissue. The reaction to polyvinyl chloride acrylic copolymer capsules implanted in the peritoneal cavity of rats and mice was therefore studied. Some animals received a slow release dexamethasone pellet, others were pretreated with doxorubicin, in an attempt to minimize the tissue reaction. The tissue reaction was significantly thicker in rats than in mice at both 2 and 6 weeks after implantation. In rats, corticoids decreased significantly the thickness of the reactive layer as compared to control at all time points studied, but doxorubicin had no effect. The tissue reaction in mice was not significantly affected by corticoid treatment. In both species the thickness of the tissue reaction did not increase significantly between 2 and 6 weeks. At 3 days the tissue reaction consisted of an interrupted single layer of macrophages in mice, whereas in rats the reaction consisted of two or three layers of macrophages and polymorphonuclear cells. At both 2 and 6 weeks, several cell layers surrounded the implants: a single layer of macrophages lying along the polymer, a variable number of layers of fibroblasts interspresed with collagen fibrils (fewer in mice than in rats, and fewer in corticoid treated rats than control rats) and an outer monolayer of mesothelial cells. We conclude that the intensity of tissue reaction to polymer implants in the peritoneal cavity is species dependent and can be decreased by the administration of corticoids but not doxorubicin.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...