ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (1,966)
  • AIRCRAFT PROPULSION AND POWER
  • SPACECRAFT DESIGN, TESTING AND PERFORMANCE
  • 1985-1989  (1,407)
  • 1975-1979  (1,091)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 36 (1988), S. 1433-1441 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Telechelic prepolymers of butadiene with aliphatic isocyanate end-groups were prepared by the solution polymerization of butadiene under free radical initiation. 4,4′-Azobis (4-cyanopentanoyl azide) was used as the initiator. Liquid prepolymers were obtained with molecular weights of 1450 to 6000 and functionalities 1.9 to 2.2. The prepolymers were characterized by their number-average molecular weight, isocyanate content, functionality, infrared, and nuclear magnetic resonance spectra and microstructure. The storage stability of the prepolymers was checked and they were found to be quite stable under ambient conditions. Isocyanate-terminated polybutadienes were reacted with N,N-dimethylamino ethanol and t-butyl hydroperoxide to obtain useful dimethylamino-terminated and peroxycarbamate-terminated prepolymers, respectively.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 36 (1988), S. 837-858 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: An extensive study on the turbulent drag reduction caused by the various mixtures of polyacrylamide, purified guargum, xanthangum, and their graft copolymers has been conducted at low concentrations and Re = 14,000 using a turbulent flow rheometer. It has been found in most of the cases that the drag reduction caused by mixtures shows a positive deviation from the linearly additive straight line. This effect is more prominent when the drag reduction caused by both the constituents differ appreciably. In most of the cases, the drag reduction caused by the mixtures is higher than the DR caused by either of the constituent polymers; however, the drag reduction caused by the mixture is less than the sum of the drag reduction caused by both the constituents at their respective concentration in the mixture. It has also been noticed that there is no evidence of synergism in these mixtures at low concentrations.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 26 (1988), S. 953-958 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The “condensed” counterions which characterize high-charge-density polyelectrolyte solutions can be analyzed into two subpopulations: (1) site-bound counterions and (2) atmospherically entrapped counterions. The distinction is achieved experimentally by combining the data from self-diffusion coefficient or electrical mobility measurements, which give the amount of “condensed” ions, and those from nmr, chemical shift measurements, which indicate the amount of site-bound ions. In the case of a solution of chondroitin sulfate with excess Co++ counterions, it can be estimated that 20% of the structural charge of the polyion is neutralized by site-bound, dehydrated, condensed counterions, while a further 30% is neutralized by atmospherically entrapped, hydrated counterions.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 37 (1989), S. 3057-3060 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 23 (1989), S. 705-718 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The peritoneal cavity is a convenient site for implantation of encapsulated hormonesecreting tissue. However, host tissue organization around such implants may affect solute exchange and viability of the encapsulated tissue. The reaction to polyvinyl chloride acrylic copolymer capsules implanted in the peritoneal cavity of rats and mice was therefore studied. Some animals received a slow release dexamethasone pellet, others were pretreated with doxorubicin, in an attempt to minimize the tissue reaction. The tissue reaction was significantly thicker in rats than in mice at both 2 and 6 weeks after implantation. In rats, corticoids decreased significantly the thickness of the reactive layer as compared to control at all time points studied, but doxorubicin had no effect. The tissue reaction in mice was not significantly affected by corticoid treatment. In both species the thickness of the tissue reaction did not increase significantly between 2 and 6 weeks. At 3 days the tissue reaction consisted of an interrupted single layer of macrophages in mice, whereas in rats the reaction consisted of two or three layers of macrophages and polymorphonuclear cells. At both 2 and 6 weeks, several cell layers surrounded the implants: a single layer of macrophages lying along the polymer, a variable number of layers of fibroblasts interspresed with collagen fibrils (fewer in mice than in rats, and fewer in corticoid treated rats than control rats) and an outer monolayer of mesothelial cells. We conclude that the intensity of tissue reaction to polymer implants in the peritoneal cavity is species dependent and can be decreased by the administration of corticoids but not doxorubicin.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 16 (1978), S. 2147-2155 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The role of the intrinsic viscosity [η] as separation parameter in gel permeation chromatography (GPC) was studied for dextrans (from Leuconostoc mesenteroids B512) dissolved in water with deactivated silicagel (Porasil) as the column-filling material. For that purpose specific viscosities of dextran fractions eluted by GPC were measured as a function of the elution volume v. Provided that the elution volumes are corrected for zonal spreading, they are related to the intrinsic viscosities in an unambiguous way, probably reflecting a unique relationship between degree of branching and molecular weights. This was further investigated by developing an iteration method to prepare two calibration curves γ(v) and g(v), respectively, relating ln[\documentclass{article}\pagestyle{empty}\begin{document}$\left[ {\bar \eta } \right]$\end {document}] and InM (M is the molecular weight) to v. It required that the weight-average molecular weight Mw, the number-average molecular weight Mn, and the average intrinsic viscosity [\documentclass{article}\pagestyle{empty}\begin{document}$\left[ {\bar \eta } \right]$\end {document}] for a number of dextran samples (broad distributions) be previously known. The calibration curves found lead to consistent values of the above-mentioned averages. Moreover, they allow-establishment of the [\documentclass{article}\pagestyle{empty}\begin{document}$\left[ {\bar \eta } \right]$\end {document}]-M relationship over the range 5000 〈 M 〈 500,000.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: The results are presented of a program designed to develop life prediction and constitutive models for two coated single crystal alloys used in gas turbine airfoils. The two alloys are PWA 1480 and Alloy 185. The two oxidation resistant coatings are PWA 273, an aluminide coating, and PWA 286, an overlay NiCoCrAlY coating. To obtain constitutive and fatigue data, tests were conducted on uncoated and coated specimens loaded in the CH76 100 CH110 , CH76 110 CH110 , CH76 111 CH110 and CH76 123 CH110 crystallographic directions. Two constitutive models are being developed and evaluated for the single crystal materials: a micromechanic model based on crystallographic slip systems, and a macroscopic model which employs anisotropic tensors to model inelastic deformation anisotropy. Based on tests conducted on the overlay coating material, constitutive models for coatings also appear feasible and two initial models were selected. A life prediction approach was proposed for coated single crystal materials, including crack initiation either in the coating or in the substrate. The coating initiated failures dominated in the tests at load levels typical of gas turbine operation. Coating life was related to coating stress/strain history which was determined from specimen data using the constitutive models.
    Keywords: AIRCRAFT PROPULSION AND POWER
    Type: NASA-CR-179594 , NAS 1.26:179594 , PWA-5968-47 , ASR-2 , AD-A173875
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: The selection procedure is described which was used to arrive at the configurations tested, and the performance characteristics of the test nozzles are given.
    Keywords: AIRCRAFT PROPULSION AND POWER
    Type: NASA-CR-135239-VOL-2
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: Acoustic data are presented scaled to a full size engine by a factor of 8 on a 96.9 m (320 ft) arc and a 731.5 m (2400 ft) sideline.
    Keywords: AIRCRAFT PROPULSION AND POWER
    Type: NASA-CR-135239-VOL-1-SECT-2
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...