ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (29)
  • Polymer and Materials Science  (27)
  • 1985-1989  (13)
  • 1975-1979  (17)
  • 1970-1974  (12)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 112-118 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Packed absorption columns ; Thick liquid phase films ; Natural, refinery, and reactor gas analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic system consisting of one multiport valve, two (hot-wire and flame-ionization) detectors and two analytical columns (one thick-film capillary and one packed adsorption column) is used for the analysis of gas samples containing a number of inorganic compounds (hydrogen, argon, oxygen, nitrogen, carbon monoxide, and carbon dioxide) and organic compounds. Examples include samples containing hydrocarbons up to n-nonane and benzene and toluene. The system also permits the analysis of more complicated samples containing, for example, alcohols, in addition to hydrocarbons.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 260-263 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: We consider the connection between viscous effects experienced by polytetrafluoroethylene paste during extrusion, and the final strength of the extrudate. It is shown that by reducing the viscous contribution to the pressure drop across the extruder die, we not only save on extrusion pressure, but also increase the strength of the extrudate. The shape of die that gives the minimum pressure drop is derived.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 28 (1986), S. 1241-1249 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Acoustic resonance densitometry (ARD) is reported as a method suitable not only for precise investigations into changes of specific gravity in bioreactor media but also as a technique able to provide an accurate wide range and direct determination of cellular mass in fermentation processes. It is further shown that this method can replace present optical procedures, minimizing dilution errors and operator involvement and is suitable for development as an on-line biomass monitoring system.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 33 (1989), S. 1379-1384 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Acoustic resonance densitometry (ARD) provides a highly reproducible and stable method for on-line measurement of culture biomass density. The technique provides a direct determination of changes in relative density of culture medium and cell mass. At cell concentrations higher than 106 cells mL-1this method can replace cell counts and provide a continuous measure of total cell mass. In cultures of hybridomas or U937 human lymphoma cells, the ARD value correlates well with cell number except when the average cell size changes during culture. It is argued that cell mass determined by ARD rather than cell number should be used as the basis for measurements of specific biological activity.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 18 (1972), S. 614-623 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Many industrial processes are difficult to control because product quality cannot be measured economically on line. One solution to this problem is to use secondary measurements in conjunction with a mathematical model of the process to estimate product quality. This paper presents a method for designing a static estimator which predicts product quality from a linear combination of process input and output measurements. The design method includes procedures for selecting a subset of the availble output measurements so as to obtain an estimator which is relatively insensitive to modeling errors and measurement noise. Application of the estimator to a simulated multicomponent distillation column shows that the composition control achieved with an estimator based on temperature, reflux, and steam flow measurements is comparable to that achieved with instantaneous composition measurements. The composition control using the estimator is far superior to the composition control achieved by attempting to maintain a constant temperature on any single stage of the column.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 24 (1978), S. 492-500 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The static estimator of part I is incorporated into a dynamic control system. The system structure minimizes output feedback and thereby achieves stability even in the event of significant modeling errors. This inherent stability permits the use of simple and economical lead-lag compensation for the estimator and controller portions of the system. The overall system response to disturbances is similar to that of feed-forward control systems.The proposed control system structure is used to infer and control the overhead and bottoms product compositions of a simulated multicomponent distillation. Product compositions are inferred from selected stage temperature and process flow measurements. Inferential control system response to various disturbances is comparable or superior to that of a tuned composition feedback control system for both single product control and for simultaneus overhead and bottoms product control.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 24 (1978), S. 485-492 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Methods are presented for the design of a static estimator which infers unmeasurable product qualities from secondary measurements. The secondary measurements are selected so as to minimize the number of such measurements required to obtain an accurate estimate which is insensitive to modeling errors. Unlike previous work, the number of secondary measurements can be fewer than the number of unmeasured disturbances. If the statistics of the disturbances and/or measurement noise are available, this information can be incorporated into the design procedure to obtain an optimal static estimator.The design procedure is illustrated by application to a simulated industrial debutanizer. Data for the simulation were supplied by the Marathon Oil Company. Deviations in bottoms product quality are compared for the current control policy (maintenance of a stage temperature at its set point) and the inferential control system with the column subjected to representative feed composition disturbances. Results show that inferential control based on four, five, or six tray temperature measurements improves the steady state control performance by as much as 400%.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 18 (1972), S. 734-738 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Bass' feedback controller design technique is extended to distributed parameter systems and its use is illustrated for a parabolic system with boundary control.The development of the design technique rests on a conjecture concerning the necessary and sufficient conditions for the asymptotic stability of linear time invariant partial differential equations. It is shown through a study of the discretized analog of a distributed system that the most likely candidate for a Lyapunov functional general enough to yield the necessary and sufficient conditions for asymptotic stability is a double integral with a symmetric kernel.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 24 (1978), S. 500-509 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Methods are presented for the construction of optimal and suboptimal estimators for inferential control systems. Optimal estimators are constructed with the aid of Kalman filtering techniques applied to linear systems driven by integrated white noise disturbances. The description of the disturbances as integrated white noise leads to optimal dynamic estimators which reduce to optimal static estimators for sustained disturbances. Suboptimal estimators are constructed by prespecifying the structure of the estimator and choosing estimator parameters so as to minimize the mean square error in estimation.Optimal and suboptimal estimators are compared by using them in an inferential control system which attempts to control the product composition of a simulated multicomponent distillation column. There is little difference in performance between optimal and suboptimal estimators which use temperature and flow measurements to estimate product composition. However, the inferential control system using a simple suboptimal estimator is significantly superior to the policy of maintaining a selected tray temperature constant through a standard feedback control system. The inferential control system is also superior to composition feedback control systems where the measurement delay is greater than 5 min.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 65-76 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A comprehensive protocol is presented for the in vivo evaluation of soft tissue foreign body reactions to surgical implants. A number of methods of evaluation and quantitation of the tissue reaction to implants are presented and discussed. A strong plea is made for semi-quantitation of tissue reactions, rather than relying on subjective, qualitative methods.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗