ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (29)
  • ASTROPHYSICS  (20)
  • Polymer and Materials Science  (6)
  • Astrophysics
  • 1990-1994  (49)
  • 1
    ISSN: 0887-624X
    Keywords: oligocyclosiloxanes ; hydrosilation ; heptamethylcyclotetrasiloxane ; siloxane redistribution ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of oligocyclosiloxanes via hydrosilation reactions has been investigated. Hydrosilation reactions employing heptamethylcyclotetrasiloxane and vinyl-containing silanes and siloxanes yielded a variety of oligocyclosiloxanes with various numbers of cyclosiloxane rings connected through tri-, tetra-, penta-, hexa-, hepta-, or octafunctional junctions. The oligocyclosiloxanes were characterized by gas chromatography, IR spectroscopy, 29Si-, 1H-, and 13C-NMR spectroscopy, elemental analysis, and vapor phase osmometry. The polycyclics were redistributed with hexamethyldisiloxane and the resulting fragments analyzed by gas chromatography. All results were consistent with the formation of isomeric oligocyclosiloxanes due to a lack of absolute regioselectivity of the hydrosilation reaction. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 36 (1990), S. 1610-1612 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 28 (1993), S. 340-343 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Ion-ion coincidence measurements following K-shell absorption in the carbon dioxide molecule were performed by applying time-of-flight mass spectrometry in conjunction with monochromatic synchrotron radiation and electron impact. Identification of particularly sensitive electronic transitions and the consecutive molecular fragmentation in real time was performed. Analysis of coincidence recordings from decomposition of carbon dioxide reveals one distinct pathway in which three cations are formed following excitation of oxygen Is electrons.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 53 (1994), S. 485-496 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new route (“direct forming”) was developed for forming dense PBI shapes from PBI powder. The new process affords the possibility of automated PBI powder shaping (“cold compaction”) and densification in batches of multiple parts by a “powder-assisted hot isostatic pressing” process. Direct forming is a more productive alternative to hot compression molding. Two developments enable PBI direct forming: (1) the discovery that PBI powders that are porous and plasticized with moisture can be shaped by compaction at ambient temperatures (cold-compacted), and (2) a finding that cold-compacted shapes can be densified in large batches by a powder-assisted hot isostatic pressing. The porous PBI powder is formed from PBI in solution by a spray-precipitation process. When plasticized with moisture, this powder is cold-compactible to PBI shapes with densities up to 94% of that of ultimate density of PBI. These shapes, which have sufficient strength to be handled, are then further consolidated via powder-assisted hot isostatic pressing to shapes with excellent thermal and mechanical properties and densities of about 99% of the ultimate. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 555-560 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The application of fast-atom bombardment mass Spectrometry and collisiorutlly induced dissociation with mass-analysed ion kinetic energy (CID/MIKE) Spectrometry of representative inositol mono-, bis- and trisphos-phates is described. Based on their CID/MIKE spectra, inositol polyphosphates containing vicinal phosphate groups could be distinguished from isomers in which adjacent phosphate groups were absent. The potential value of this procedure in studies of the biochemistry of intracellular second messengers is discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The need for alternatives to autogenous bone grafts is widely recognized. This study compared the torsional strength of canine femora 1 year after grafting with one of three forms of a collagen/hydroxyapatite/tricalcium phosphate bone grafting material (COLLAGRAFT15), autogenous bone, or no graft. The groups were compared to each other and to the unoperated contralateral femora. Results of torsional testing were evaluated for torsional strength, torsional displacement, total energy to fracture and White fracture mode. Data analysis showed lower torsional strength of the operated vs. unoperated femora with the exception of morsellized COLLAGRAFT15 material, which had higher strength. However, the only difference in the operated groups was that the morsellized COLLAGRAFT15 had greater strength than several groups including the autogenous bone group. There was no difference found in angular displacement between any of the groups. However, there was a difference in the energy to fracture in both strip forms of the COLLAGRAFT15. The final conclusion is that in this model, grafting with COLLAGRAFT15 provided torsional properties at one year postoperatively at least equivalent to autogenous bone. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 217-221 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Nanogram quantities of glucuronic acid conjugates of GR117289 in rat and dog bile have been analysed by semi-microbore high-performance liquid chromatography (HPLC)/ionspray mass spectrometry with on-line UV diode array detection. The determination of drug metabolites in bile has often proved problematical due to the large number of endogenous components in this biological matrix, in particular the bile acids. Semi-microbore HPLC is useful for concentrating small quantities of material and, in combination with an on-line diode array detector, for distinguishing between drug related and endogenous components. A novel angiotensin II receptor antagonist, GR117289, had proved difficult to analyse by thermospray mass spectrometry because of its thermal lability. The use of the less thermally dependent technique of ionspray mass spectrometry allowed the characterization of nanogram quantities of glucuronic acid metabolites of GR117289 in bile.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal für Praktische Chemie/Chemiker-Zeitung 332 (1990), S. 277-292 
    ISSN: 0021-8383
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Different adsorption isotherms such as the Szyszkowski, Temkin, Frumkin, polynomial and spline functions were explore as fits to the experimental interfacial tension isotherms for LIX-63-hexane/water and LIX-63-toluene/water systems and then the surface excess isotherms were computed. A good match was obtained. The surface excess isotherms change in a similar way as those reported previously for 2-hydroxy-5-alkylbenzophenone oximes.Kinetic equations were derived for various versions of the extraction mechanism at the molecular interface, and the interfacial tension data were then used to estimate reaction orders against hydroxyoxime concentrations assuming that the process occurs at the interface of molecular dimensions. A reaction order equal one was obtained in the case of the formation of the stable 2:1 complex from the surface adsorbed intermediate 1:1 complex with a hydroxyoxime molecule held in the aqueous sublayer. This is the slowest step in the overall process. Hydroxyoxime association has only a small effect upon the predicted reaction orders and can be neglected.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 79-94 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An accelerated anodic corrosion method was used to study the effects of heat treatment and bead size on corrosion and metal ion release of porous coated F75 cylinders in saline and serum. Three heat treatments were used: a standard process for F75 implants (HTA), the standard plus an additional hour in air to produce a thin oxide film (HTA′), and a sintering in high vacuum to produce a chromium-depleted surface (HTB). Three bead sizes of similar composition were used, with approximate sizes of 215, 300, and 560 μm. The results demonstrated that HTA′ had the lowest corrosion rate and that of HTB was significantly greater than either HTA or HTA′. The corrosion rates of HTA and HTA′ were significantly greater in serum as compared with saline, whereas that of HTB was not affected by the presence of serum, suggesting an interaction between chromium and serum proteins. Bead size had a minimal effect on the corrosion rate of HTA′. For HTA, the small beads had the highest corrosion rate; the lowest was with the medium-sized beads. Bead size had the most significant effect with HTB, with that of the smaller beads having the higher corrosion rates. The effects of bead size were less consistent in serum, suggesting that protein adsorption may mask some of the surface area effects. It is concluded that the oxide film does reduce corrosion, that proteins do have an influence on the corrosion of F75, and that this method can be a suseful tool for studying the effects of improved heat treatment methods on the corrosion rate of F75 implants.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The tissue response and in vivo molecular stability of injection-molded polyhydroxyacids - polylactides (PLA), poly(3-hydroxybutyrate) (PHB), and poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHB/VA, 5-22% VA content) - were studied. Polymers were implanted subcutaneously in mice and extirpated at 1, 3, and 6 month in order to study tissue response and polymer degradation.All polymers were well tolerated by the tissue. No acute inflammation, abscess formation, or tissue necrosis was observed in tissues adjacent to the implanted materials. Furthermore, no tissue reactivity or cellular mobilization was evident remote from the implant site. Mononuclear macrophages, proliferating fibroblasts, and mature vascularized fibrous capsules were typical of the tissue response. Degradation of the polymers was accompanied by an increase in collagen deposition. For the polylactide series, the inflammatory response after 1 month of implantation was less for materials containing the D-unit in the polymer chain, whereas in the case of the polyhydroxybutyrate/valerates, the number of inflammatory cells increased with increasing content of the valerate unit in the polymer chain. Between 1-3 months, there was slightly more tissue response to the PHB and PHB/VA polymers than to PLA. This response is attributed to the presence of leachable impurities and a low molecular weight soluble component in the polyhydroxybutyrate/valerates. At 6 months, the extent of tissue reaction was similar for both types of polymers.All polylactides degraded significantly (56-99%) by 6 months. For a poly(L-lactide) series, degradation rate in vivo decreased with increasing initial molecular weight of the injection-molded polymer. Several samples showed pronounced bimodal molecular weight distributions (MWD), which may be due to differences in degradation rate, resulting from variability in distribution of crystalline and amorphous regions within the samples. This may also be the result of two different mechanisms, i.e., nonenzymatic and enzymatic, which are involved in the degradation process, the latter being more extensive at the later stage of partially hydrolyzed polymer. The PHB and PHB/VA polymers degraded less (15-43%) than the polylactides following 6 months of implantation. Generally, the polymer with higher valerate content (19%, 22% degraded most. The decrease in molecular weight was accompanied by a narrowing of the MWD for PHB and copolymers; there was no evidence of a bimodal MWD, possibly indicating that the critical molecular weight that would permit enzyme/polymer interaction had not been reached. Weight loss during implantation ranged from 0-50% for the polylactides, whereas for the PHB polymers weight loss ranged from 0-1.6%. © 1993 John Wiley & Sons, Inc.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...