ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • ASTROPHYSICS  (20)
  • Polymer and Materials Science  (12)
  • Astrophysics
  • 1990-1994  (26)
  • 1960-1964  (6)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 5 (1961), S. 580-588 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Torsional modulus-temperature data have been obtained on heterogeneous polymer compositions prepared by several procedures. Both the state of aggregation of the component chain molecules and their degree of compatibility are significant variables. Modulus curves similar to those for crystalline polymers can be obtained from incompatible polymers having glass temperatures sufficiently far apart. Detailed interpretations are presented for modulus curves of both individual homopolymers and bicomponent heterogeneous polymer mixtures.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0887-624X
    Keywords: oligocyclosiloxanes ; hydrosilation ; heptamethylcyclotetrasiloxane ; siloxane redistribution ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of oligocyclosiloxanes via hydrosilation reactions has been investigated. Hydrosilation reactions employing heptamethylcyclotetrasiloxane and vinyl-containing silanes and siloxanes yielded a variety of oligocyclosiloxanes with various numbers of cyclosiloxane rings connected through tri-, tetra-, penta-, hexa-, hepta-, or octafunctional junctions. The oligocyclosiloxanes were characterized by gas chromatography, IR spectroscopy, 29Si-, 1H-, and 13C-NMR spectroscopy, elemental analysis, and vapor phase osmometry. The polycyclics were redistributed with hexamethyldisiloxane and the resulting fragments analyzed by gas chromatography. All results were consistent with the formation of isomeric oligocyclosiloxanes due to a lack of absolute regioselectivity of the hydrosilation reaction. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 5 (1961), S. 337-348 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The predicted general incompatibility of mixtures of polymers has been further confirmed. Thirty-one mixtures of homopolymer pairs showed phase separation in a common solvent. These included closely related polymers such as polyacrylates with both polymethacrylates and other polyacrylates and pairs of different polymethacrylates. Typical immiscible combinations are PMA/PEA and PEMA and PEMA/PMMA. It was also found that the presence of a common monomer constituent did not result in complete compatibility of either a homopolymer with a copolymer or a mixture of two copolymers. Apparently, none of the combinations tried were sufficiently similar to result in heats of interaction small enough to be counteracted by the small entropy change involved. Since another possibility for attaining miscibility is through polar interactions, the effects of ionic and hydrogen-bonding substituents upon polymer-polymer compatibility were considered, and selected experiments were done on a series of carboxyl-containing polymers and their sodium salts. It was concluded that hydrogen bridging occurs preferentially either intramolecularly or between polymer and solvent rather than between two different types of chains each having hydrogen-bonding ability. Thus, poly(acrylic acid) and poly(methacrylic acid) show two-phase separation in water. Although poly(sodium acrylate) and poly(sodium methacrylate) are completely miscible, mixtures of the partially neutralized acids, e.g., PAA and PNaMA mixtures, show separation. In contrast to predictions for less polar polymers, compatibility of mixtures of polymers containing high mole fractions of carboxylic acid monomers showed a pronounced dependence upon solvent. Thus, the two copolymers 45/53 EA-MAA and 47/53 MMA-MAA are incompatible in methanol or ethanol but form homogeneous solutions in DMF or DMS.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 53 (1994), S. 485-496 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new route (“direct forming”) was developed for forming dense PBI shapes from PBI powder. The new process affords the possibility of automated PBI powder shaping (“cold compaction”) and densification in batches of multiple parts by a “powder-assisted hot isostatic pressing” process. Direct forming is a more productive alternative to hot compression molding. Two developments enable PBI direct forming: (1) the discovery that PBI powders that are porous and plasticized with moisture can be shaped by compaction at ambient temperatures (cold-compacted), and (2) a finding that cold-compacted shapes can be densified in large batches by a powder-assisted hot isostatic pressing. The porous PBI powder is formed from PBI in solution by a spray-precipitation process. When plasticized with moisture, this powder is cold-compactible to PBI shapes with densities up to 94% of that of ultimate density of PBI. These shapes, which have sufficient strength to be handled, are then further consolidated via powder-assisted hot isostatic pressing to shapes with excellent thermal and mechanical properties and densities of about 99% of the ultimate. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The need for alternatives to autogenous bone grafts is widely recognized. This study compared the torsional strength of canine femora 1 year after grafting with one of three forms of a collagen/hydroxyapatite/tricalcium phosphate bone grafting material (COLLAGRAFT15), autogenous bone, or no graft. The groups were compared to each other and to the unoperated contralateral femora. Results of torsional testing were evaluated for torsional strength, torsional displacement, total energy to fracture and White fracture mode. Data analysis showed lower torsional strength of the operated vs. unoperated femora with the exception of morsellized COLLAGRAFT15 material, which had higher strength. However, the only difference in the operated groups was that the morsellized COLLAGRAFT15 had greater strength than several groups including the autogenous bone group. There was no difference found in angular displacement between any of the groups. However, there was a difference in the energy to fracture in both strip forms of the COLLAGRAFT15. The final conclusion is that in this model, grafting with COLLAGRAFT15 provided torsional properties at one year postoperatively at least equivalent to autogenous bone. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 7 (1963), S. 59-69 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The isolation of two graft copolymers of styrene on polyethyl acrylate from the ungrafted homopolymers by solvent extraction procedures is discussed. For the grafts and their corresponding mixtures ηsp/c versus c plots were determined, and no anomalies were observed. Qualitative data on the solubilities and phase properties of the grafts are given. Torsional modulus-temperature curves are shown for graft copolymer and the individual homopolymers.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 8 (1964), S. 1541-1548 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Differential thermal analysis (DTA) and thermogravimetric analysis (TGA) of poly(ethylene terephthalate) has been carried out on samples of amorphous, cold-drawn, heat-crystallized, and acetone-crystallized polymer. From DTA it appears that for amorphous material a prolonged “secondary” crystallization process follows a primary process in the region of 140°C. For cold-drawn polymer, heat treatment does not reflect differences observed in previous x-ray diffraction studies. The TGA gives evidence that a high temperature endothermic peak observed in DTA may not be directly associated with depolymerization. With acetone-crystallized material a high degree of acetone retention is detected.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 79-94 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An accelerated anodic corrosion method was used to study the effects of heat treatment and bead size on corrosion and metal ion release of porous coated F75 cylinders in saline and serum. Three heat treatments were used: a standard process for F75 implants (HTA), the standard plus an additional hour in air to produce a thin oxide film (HTA′), and a sintering in high vacuum to produce a chromium-depleted surface (HTB). Three bead sizes of similar composition were used, with approximate sizes of 215, 300, and 560 μm. The results demonstrated that HTA′ had the lowest corrosion rate and that of HTB was significantly greater than either HTA or HTA′. The corrosion rates of HTA and HTA′ were significantly greater in serum as compared with saline, whereas that of HTB was not affected by the presence of serum, suggesting an interaction between chromium and serum proteins. Bead size had a minimal effect on the corrosion rate of HTA′. For HTA, the small beads had the highest corrosion rate; the lowest was with the medium-sized beads. Bead size had the most significant effect with HTB, with that of the smaller beads having the higher corrosion rates. The effects of bead size were less consistent in serum, suggesting that protein adsorption may mask some of the surface area effects. It is concluded that the oxide film does reduce corrosion, that proteins do have an influence on the corrosion of F75, and that this method can be a suseful tool for studying the effects of improved heat treatment methods on the corrosion rate of F75 implants.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The tissue response and in vivo molecular stability of injection-molded polyhydroxyacids - polylactides (PLA), poly(3-hydroxybutyrate) (PHB), and poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHB/VA, 5-22% VA content) - were studied. Polymers were implanted subcutaneously in mice and extirpated at 1, 3, and 6 month in order to study tissue response and polymer degradation.All polymers were well tolerated by the tissue. No acute inflammation, abscess formation, or tissue necrosis was observed in tissues adjacent to the implanted materials. Furthermore, no tissue reactivity or cellular mobilization was evident remote from the implant site. Mononuclear macrophages, proliferating fibroblasts, and mature vascularized fibrous capsules were typical of the tissue response. Degradation of the polymers was accompanied by an increase in collagen deposition. For the polylactide series, the inflammatory response after 1 month of implantation was less for materials containing the D-unit in the polymer chain, whereas in the case of the polyhydroxybutyrate/valerates, the number of inflammatory cells increased with increasing content of the valerate unit in the polymer chain. Between 1-3 months, there was slightly more tissue response to the PHB and PHB/VA polymers than to PLA. This response is attributed to the presence of leachable impurities and a low molecular weight soluble component in the polyhydroxybutyrate/valerates. At 6 months, the extent of tissue reaction was similar for both types of polymers.All polylactides degraded significantly (56-99%) by 6 months. For a poly(L-lactide) series, degradation rate in vivo decreased with increasing initial molecular weight of the injection-molded polymer. Several samples showed pronounced bimodal molecular weight distributions (MWD), which may be due to differences in degradation rate, resulting from variability in distribution of crystalline and amorphous regions within the samples. This may also be the result of two different mechanisms, i.e., nonenzymatic and enzymatic, which are involved in the degradation process, the latter being more extensive at the later stage of partially hydrolyzed polymer. The PHB and PHB/VA polymers degraded less (15-43%) than the polylactides following 6 months of implantation. Generally, the polymer with higher valerate content (19%, 22% degraded most. The decrease in molecular weight was accompanied by a narrowing of the MWD for PHB and copolymers; there was no evidence of a bimodal MWD, possibly indicating that the critical molecular weight that would permit enzyme/polymer interaction had not been reached. Weight loss during implantation ranged from 0-50% for the polylactides, whereas for the PHB polymers weight loss ranged from 0-1.6%. © 1993 John Wiley & Sons, Inc.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 16 (1992), S. 119-125 
    ISSN: 0308-0501
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Architecture, Civil Engineering, Surveying , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: This study is based on the use of integral, hybrid thermal barrier to protect the core of the composite structure. Thermal barrier treatments evaluated in this study include ceramic fabric, ceramic coating, intumescent coating, hybrid of ceramic and intumescent coating, silicone foam, and phenolic skin. The composite systems evaluated in combination with thermal barrier treatments included glass/vinyl ester, graphite/epoxy, graphite/bismaleimide, and graphite/phenolic. All configurations were tested for flammability characteristics. These included smoke density and combustion gas generation (ASTM E-662), residual flexural strength (ASTM D-790), heat release rate, and ignitability (ASTM E-1354). ASTM E-662 test method covers the determination of specific optical density of smoke generated by solid materials. ASTM D-790 test method covers the determination of flexural properties of composite materials in the form of rectangular bars. ASTM E-1354 (cone calorimeter) covers the measurement of the response of materials exposed to controlled levels of radiant heating with or without an external ignitor, and is used to determine the ignitability, heat release rates, mass loss rates, effective heat of combustion, and visible smoke development. Without any fire barrier treatments, all composite systems evaluated in this study failed to meet ignitability and peak heat release requirements of MIL-STD-2031 (SH) at radiant heat fluxes of 75 and 100 kW m-2, respectively. Intumescent coating and a hybrid system consisting of intumescent coating over ceramic coating were the most effective fire barrier treatments for composite systems evaluated in this study. Using either of these treatments, all composite systems met the ignitability requirements of 90 and 60 at 75 and 100 kW m-2, respectively. Except for glass/vinyl ester, all systems also met the peak and average heat release requirements of MIL-STD-2031 (SH) at radiant heat fluxes of 25, 75, and 100 kW m-2, respectively.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...