ISSN:
0197-8462
Keywords:
dielectric heaters
;
body currents
;
SARs
;
Life and Medical Sciences
;
Occupational Health and Environmental Toxicology
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Biology
,
Physics
Notes:
Data are presented on ankle-specific SARs and foot currents as a function of strengths of radio-frequency electromagnetic fields encountered by operators of dielectric heaters. The determination of foot currents was based on near-field exposures in which reactive coupling dominates, and which can result in substantial SARs in exposed workers. The operators were located less than one wavelength from - usually within one meter of - the dielectric heaters, which generated fields at frequencies from 6.5 to 65 MHz. At distances normally assumed by workers, maximal strengths of electric fields ranged from 104 to 2.4 × 106 V2/m2; maximal strengths of magnetic fields ranged from 5.0 × 10-3 to 33.3 A2/m2. Currents through both feet to ground were measured while operators stood where they normally worked. Maximal currents ranged from 3 to 617 mA, rms. Nearly 27 percent of the dielectric heaters induced foot currents that exceeded the 200-mA limit that has been proposed for a new ANSI C95.1 standard. Twenty percent of the heaters induced foot currents that exceeded 350 mA. SARs in ankles were calculated from foot currents, and they approximated 5 W/kg at 100 mA, 29 W/kg at 250 mA, and 57 W/kg at 350 mA. The maximal SAR in the ankle was ∼ 176 W/kg at 617 mA. © 1992 Wiley-Liss, Inc.
Additional Material:
1 Tab.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/bem.2250130204
Permalink