ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (18)
  • Gas chromatography
  • Wiley-Blackwell  (18)
  • 1990-1994  (5)
  • 1975-1979  (13)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 288-292 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases, polar, gum type ; For temperatures up to 300°C ; For most of the common classes of organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Most of the common classes of organic compounds chromatograph normally on Superoxes. There is no tailing or adverse effect from excessively different activity different activity coefficients. Superoxes are therefore universal phases for gas chromatography. This is also expressed by a wide useful temperature range from ∼50° to ∼300°. High MW Superox-4 has a MAOT about 20° higher than the lower MW Superox-0.1. Several applications illustrating the versatility of Superox phases in (GC)2 are presented.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 283-287 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling technique ; Semi-automation of head space sampling ; Application to water pollution, coffee aroma, light hydrocarbons in crude oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Head space GC using a special electropneumatic sampling system works well in combination with glass capillaries. Because a homogenous gas mixture is already present most problems inherent with inlet splitters are thus avoided. In cases where the high vapor pressure of the sample can cause problems with the pressure controlled sampling system, the use of narrow bore glass capillaries provides the necessary inlet pressure. The use of this powerful and convenient analytical tool for water pollution analysis, flavour analysis and the analysis of volatiles in crude oil samples is shown by examples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 487-496 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Comparison of FID, ECD, FPD for detection limit. linearity, peak shape etc. ; Practical results for pesticide residue and coal hydrogenation products given ; Concentration dependent detectors in capillary GC interesting, when optimized ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the characteristics and Performance of the flame ionization, electron capture, and flame photometric detectors with capillary columns is described. Factors which may affect the limits of detection, linearity, chromatographic peak shape, and other detector performance characteristics are discussed and compared with the results of a model derived for the behavior of concentration and mass flow-rate dependent chromatographic detectors used with capillary GC systems. Examples are given of highly complex and labile mixtures such as pesticide residues and products from coal hydrogenation.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 187-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Whiskers, OV-17 ; Steroid profiling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 217-218 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Quantitative analysis of cholesterol ; Stigmasterol as internal standard ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 712-714 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Cholesteric liquid crystal phase ; Separation of geometrical isomers ; Cholesteryl cinnamate ; Insect pheromones ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 301-301 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, rapid preparation ; Quartz powder surface roughening ; Ideal for thick film impregnations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 303-311 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Overview, preparation and evaluation techniques ; Quantitation is the least satisfactory aspect of (GC)2 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of (glass) capillary columns of high quality is still not without difficulties. Six problems in this context are highlighted. Column material choice(l), glass wall modification(2) and coating(3) are considered to have reached a satisfactory level. Deactivation(4) is still in a state of flux. Quantitation(5) is the least satisfactory aspect of capillary GC. Scope expansion(6) will be helped by the introduction of new phases of high thermal stability and by the adoption of solutions exclusively applicable to capillary GC.Evaluation of (glass) capillary GC columns is a rapidly developing field. Hopefully the number and complexity of test or polarity mixtures will not expand much further and it will be possible to make a clear and generally acceptable choice.The preparation and evaluation of ever-improving capillary columns is important to an ever-widening group of chromatographers. Our opinion on selected topics in this already vast field is summarized in the following overview.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 249-250 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Deactivation stable up to 35O°C ; High temperature phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method of deactivating the inner surface of glass capillary columns is described, which can be used at 350°C without detoriation. A non-polar liquid phase was prepared from a commercially available liquid phase which, when coated on a glass surface, can withstand temperatures of 325°C for isothermal analysis and 350°C for temperature-programmed analysis.After deactivation, the column was coated using the static coating method. Then it was conditioned, tested and kept for 48 hours at 35O°C before being used for the analysis of a mixture of chlorinated pesticides.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 475-480 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Photoionization detector (PID) ; Detection limit 50 to 100 pg nitrosamines at 10.2 eV ; Nitrosamine analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of a photoionization detector (PID) coupled to a glass capillary gas chromatography (GC2) separation system for the detection of carcinogenic nitrosamines was investigated. The components analyzed gave a linear response with a lower detection limit of 50 to 100 pg with the 10.2 eV ionization source. No detector response was obtained with an ionization energy of 9.5 eV.Chromatography of meat extracts indicated their complex molecular composition. Simple liquid chromatographic cleaning procedures significantly decreased the complexity of these samples, but not sufficiently for the accurate quantition of nitrosamine components.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...