    Publication Date: 2011-08-24
    Description: A thermometer using the temperature dependence of the magnetic penetration depth in superconductors is described which has the potential for temperature resolution, when using a dc SQUID readout, on the order of 1 pK. One such device has been fabricated and characterized to demonstrate proof of concept. It consists of primary and secondary coils of NbTi wire wound on a copper toroidal core on which a thin layer of In (Tc = 3.4 K) has been deposited. The temperature dependence of the mutual inductance, M(T), or self-inductance, is used to detect changes in temperature. Measurements of M(T) have been made with an ac excitation of the primary for various frequencies and peak magnetic field strengths. Estimates of ultimate temperature resolution are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Applied Superconductivity (ISSN 1051-8223); 3; 1, pt; p. 2140-2143.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: A new class of high detectivity pyroelectric detectors developed for optimization of the radiation measurement system within the framework of the Atmospheric Radiation Measurement program is described. These devices are intended to provide detectivities of up to about 10 exp 11 cm Hz exp 0.5/W with cooling to about 100 K required for the detector focal plane.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: ; : Analysis of optica
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: The performance of a 640 x 480 PtSi, 3,5 microns (MWIR), Stirling cooled camera system with a minimum resolvable temperature of 0.03 is considered. A preliminary specification of a full-TV resolution PtSi radiometer was developed using the measured performance characteristics of the Stirling cooled camera. The radiometer is capable of imaging rapid thermal transients from 25 to 250 C with better than 1 percent temperature resolution. This performance is achieved using the electronic exposure control capability of the MOS focal plane array (FPA). A liquid nitrogen cooled camera with an eight-position filter wheel has been developed using the 640 x 480 PtSi FPA. Low thermal mass packaging for the FPA was developed for Joule-Thomson applications.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: In: Infrared technology XVIII; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-32826 12-35); p. 386-400.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 317-328
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2006-02-14
    Description: The objective of this experiment is to measure the flux and energy spectrum of protons with energies of 1 to MeV. These protons are trapped on the Earth's magnetic field lines as part of the inner radiation belt, or Van Allen zone. The proton will be encountered predominantly in the South Atlantic anomaly at a 90 deg pitch angle.
    Keywords: SPACE RADIATION
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 109-112
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The astrometric and photometric performance of the PDS 1010A microdensitometer are discussed, including the tests used for checking it. The instrument was shown to satisfy operational requirements for photometric measurements of astronomical plates with respect to dynamic range and stability.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 89-95
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: Results obtained from five techniques for measuring gas-phase ammonia at low concentration in the atmosphere are compared. These methods are: (1) a photofragmentation/laser-induced fluorescence (PF/LIF) instrument; (2) a molybdenum oxide annular denuder sampling/chemiluminescence detection technique; (3) a tungsten oxide denuder sampling/chemiluminescence detection system; (4) a citric-acid-coated denuder sampling/ion chromatographic analysis (CAD/IC) method; and (5) an oxalic-acid-coated filter pack sampling/colorimetric analysis method. It was found that two of the techniques, the PF/LIF and the CAD/IC methods, measured approximately 90 percent of the calculated ammonia added in the spiking tests and agreed very well with each other in the ambient measurements.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 97; D11,; 11
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-19
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA, Washington Upper Atmosphere Res. Program; p 236-237
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2013-08-29
    Description: This paper describes the design, fabrication, test, and operation of a unique six axis force/torque dynamometer The specimen table used to hold components under test is supported in a full six axis kinematic mount. Support struts fabricated from high strength steel with special integral two axis flexures link the specimen table to the load cell transducers. Realtime force/torque coordinate transform, root mean squared calculation, and data averaging, and color six axis display with controllable scaling are provided by a specially programmed desktop computer. The extensive structural analysis and design optimization required to obtain a stiff, well damped, lightweight structure is described in detail. Geometric optimization of the kinematic mount and fabrication details of the struts are also described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center, The 26th Aerospace Mechanisms Symposium; p 331-348
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2011-08-17
    Description: The spectrum of the extragalactic diffuse X-ray background has been measured with the GSFC Cosmic X-ray Experiment on HEAO 1 for regions of the sky away from known point sources and more than 20 deg from the galactic plane. A total exposure of 80 sq m-s-sr is available at present. Free-free emission from an optically thin plasma of 40 plus or minus 5 keV provides an excellent description of the observed spectrum from 3 to 50 keV. This spectral shape is confirmed by measurements from five separate layers of three independent detectors. With an estimated absolute precision of about 10%, the intensity of the emission at 10keV is 3.2 keV/keV/sq cm/s/sr, a value consistent with the average of previously reported spectra. A uniform hot intergalactic medium of approximately 36% of the closure density of the universe would produce such a flux, although nonuniform models indicating less total matter are probably more realistic.
    Keywords: SPACE RADIATION
    Type: Astrophysical Journal; vol. 235
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...