ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (21)
  • Amino Acid Sequence  (6)
  • Inorganic Chemistry
  • Protein Conformation
  • 1990-1994  (16)
  • 1980-1984  (11)
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 30 (1992), S. 2677-2681 
    ISSN: 0887-624X
    Keywords: polystyrene ; photooxidation ; oxygen ; nitrous oxide ; ultraviolet ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Strips of polystyrene held in a flowing O2 or N2O atmosphere have been exposed to 240-600 nm radiation. The extent of photooxidation has been followed by x-ray photoelectron spectroscopy (XPS). Although N2O is a more reactive gas than O2, it produces a less oxidized polymer surface. This surprising observation can be correlated to the photochemistry occurring at the gas/polystyrene interface. © 1992 John Wiley & Sons, Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 697-699 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns, 100 μm I.D. ; On-column injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 427-430 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electron capture detector ; Cell design ; Time constant, purge flow ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A comparison of the effects on peak shape is made between a 350 and 100 microliter displaced coaxial and a 350 microliter concentric cylinder electron capture cell. Peaks as fast as W1/2 = 0.5 second were detected using electronics operating in the constant current mode. The measured peak shapes are compared to those obtained by computer simulation assuming either complete mixing or plug-like flow within ECD cell. The advantage of controlling the flow pattern through the cell to obtain plug-like flow is demonstrated. Differences in peak shape between the displaced coaxial and concentric cylinder cells of the same volume are explained in terms of the electrostatic fields within the cells.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 53-55 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Plant extract ; Photochemical degradation ; Insecticides ; Volatile compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 651-654 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electron capture detector ; Cell design ; Hydrogen carrier gas ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new design for an electron capture detector cell is described. The cell is compatible with the requirements of high resolution capillary columns and is shown to be useful in applications that require high analysis speed. A unique method of sample introduction reduces the problems of sample loss by adsorption on the surfaces of the cell. Previously reported problems of sample loss by adsorption on active surfaces within the cell when using hydrogen carrier gas are shown to have been eliminated. Examples are shown demonstrating the increased speed of analysis that can be obtained when using hydrogen carrier gas and 100 micron diameter columns.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Heteroatom Chemistry 1 (1990), S. 475-478 
    ISSN: 1042-7163
    Keywords: Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthesis and characterization of (Me3Si)2AsCH2RCH2As(SiMe3)2 [R = CH2 (1), SiMe2 (2)] is described. Compound 1 reacts with four equivalents of Ph2GaCl to produce (3), whose structure was deduced by use of 1H and 13C{1H} NMR spectroscopy.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Advanced Materials for Optics and Electronics 1 (1992), S. 29-36 
    ISSN: 1057-9257
    Keywords: Gallium-arsenic compounds ; Single-source ; gallium ; arsenide ; precursors ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Reactions of GaX3 (X = Br, I) with As(SiMe3)3 in 1:1 and 2:1 mole ratios were investigated. For the latter reactant stoichiometry, substances having the empirical formulae AsBr3Ga2 (1) and Asl3Ga2 (2), the analogues of the previously reported single-source GaAs precursor (AsCl3Ga2)n, were isolated as yellow isolated as yellow insoluble powders. Low-temperature reactions in a 1:1 mole ratio resulted in the isolation of the adducts Br3Ga.As(SiMe3)3 (3) and I3Ga.As(SiMe3)3 (4). On the other hand, at room temperature the GaBr3 reaction resulted in a complex mixture from which no characterizable compounds were isolated, whereas the Gal3 reaction afforded the crystalline compound [I2GaAs(SiMe3)2]2 (5). The structures of 4 and 5 were elucidated by complete single-crystal X-ray analysis (crystal data: 4, monoclinic, space group P21/c, a = 16.497(2) Å, b = 9.629(1) Å, c = 16.658(2) Å, β = 113.21(1)°, V = 2432(1) Å3, Z = 4; 5, orthorhombic, space group Pbca, a = 14.279(2) Å, b = 17.509(2) Å, c = 13.818(2), Å, V = 3455(1) Å3, Z = 4).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 21 (1981), S. 809-815 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Temperature dependence of resistance of carbon black loaded ethylene-vinylacetate (EVA) copolymer was studied from -100 to 250°C in a modified differential scanning calorimeter (DSC) apparatus. Both room temperature resistivity and positive temperature coefficient of resistance (PTC) effects can be correlated with carbon black parameters (structure, surface area, porosity). Room temperature resistivity and the degree of increase of resistivity, (ratio of maximum to minimum) progressively decrease with carbon black structure if occlusion of polymer by carbon black is considered in calculating the volume fraction. An integrated surface areastructure-porosity equivalence of the carbon black is derived by introducing factors proportional to the volume and porosity of the black used. Any black parameter that increases conductivity (loading, surface area, structure, porosity) decreases the PTC effect. A cable compounder can therefore minimize the undesirable impact of PTC by suitable choice of black-parameters. The necessary considerations for other uses, where PTC effect is used for microswitches, heaters, etc., will be just the opposite. The modified DSC method provides a quick scanning tool for determining the suitability of semicrystalline polymer recipes, either for cable or for any other material using the PTC effect.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 43-45 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The versatility of the quadrupole ion trap as a mass spectrometer in which the mass resolution may be varied over a wide range has been demonstrated. Mass resolution of 0.8 × 107 and 1.2 × 107 have been obtained for ions of m/z 414 and m/z 614, respectively, well in excess of the normal value of 3m, where m is the mass of ion. At the highest mass resolution, peak-widths at half-maximum are but 52 × 10-6 u. While it has been shown previously that enhanced mass reslution in the quadrupole ion trap can be achieved by reduction of the mass scanning rate, the range of mass resolutions reported here were achieved by reducing the mass scanning rate, in stages, by an overall factor of ca 5.5 × 104.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 17 (1981), S. 26-27 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The influence of substituents on the 199Hg chemical shifts of some Ar2Hg and ArHgCl species in 1:1 CDCl3: CH2Cl2 and in CDCl3: DMSO solutions is reported. The effects are substantial and are in the direction of electron withdrawal producing increased shielding (i.e. shifts towards higher field).
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...