ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Institute of Physics (AIP)  (3)
  • 1990-1994  (3)
  • 1980-1984
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3090-3092 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Four hydrogen pellets, two of 3 mm(large-closed-square)×3 mml pellets and two of 4 mmF(Slashthrough accent mark)×4 mml pellets, with the velocity of ∼2.3 km/s, were injected to OH and NB heated plasmas by a four-barrel pneumatic injector on the JT-60 tokamak. The pellet ablation profile was estimated by the measurement of the Hα emissions originating from the ablation cloud using a fiber optics array combined with the Hα -filtered multichannel photodiode. The fiber optics array consisting of ten channel bundles views the pellet pass in the vacuum vessel. The optical fiber was developed to tolerate baking up to 300 °C. The measured ablation profiles were compared with the calculated one by the neutral gas shielding model with a self-limiting effect. A good agreement was obtained between measured and calculated ablation profiles in OH plasmas; however, the fast-ion-induced ablation needed to be taken into account in the calculation for NB-heated plasmas.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 3524-3527 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A broadband reflectometric system in O-mode operation has been developed for the density profile determination, MHD and turbulent fluctuation measurement, and evaluation of the particle diffusion coefficient in the JT-60 tokamak. For the profile determination, full Ka-Q band frequencies of BWOs have been swept in 750 μs, in order to minimize the effect of doppler shift due to the fluctuation of reflection layers. The heterodyne fixed-frequency reflectometer has unveiled its effectiveness to probe MHD activities, diagnosing the m=1 tearing mode oscillations. It has also enabled the observation of the dramatic suppression of edge plasma density fluctuations at the L- to H-mode transition in the LHCD limiter plasma. Furthermore, the propagation delay of density pulses has been observed by different fixed-frequency channels during a series of sawteeth, from which the particle diffusion coefficient was evaluated, with a newly proposed method applicable to fully diffusive plasmas.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A broadband reflectometric system in O-mode operation has been developed for the density profile determination, MHD and turbulent fluctuation measurement, and evaluation of the particle diffusion coefficient in the JT-60 tokamak. For the profile determination, full Ka-Q band frequencies of BWOs have been swept in 750 μs, in order to minimize the effect of Doppler shift due to the fluctuation of reflection layers. The heterodyne fixed-frequency reflectometer has unveiled its effectiveness to probe MHD activities, diagnosing the m=1 tearing mode oscillations. It has also enabled the observation of the dramatic suppression of edge plasma density fluctuations at the L to H-mode transition in the LHCD limiter plasma. Furthermore, the propagation delay of density pulses has been observed by different fixed-frequency channels during a series of sawteeth, from which the particle diffusion coefficient was evaluated, with a newly proposed method applicable to fully diffusive plasmas.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...