The ground-water flowmeter system, model 3OL, manufactured by K-V Associates Inc., Falmouth, Massachusetts was tested under controlled laboratory conditions. The influence of slotted pipe schedule, slot orientation, backfill materials, endcap bags, isolated regions of high hydraulic conductivity, and channelization near the slotted pipe wall was measured. The physical concept of the flow-meter in an ideal configuration was analyzed, and with the aid of an analytical model, the significance of the thermal and hydraulic characteristics of the aquifer and backfill materials is clarified. Results indicate that the basic instrument response is linear, consistent, and predictable qualitatively in a laboratory environment. Analysis and measurements show clearly that very small channelization around a slotted pipe casing or between the slotted pipe and the probe endcap can invalidate the instrument response. Additional potential complications arise due to unknown permeability contrasts between the aquifer matrix and the material used to backfill around the probe.