ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 65C99  (1)
  • Citrus  (1)
  • DSC  (1)
  • Springer  (3)
  • 1990-1994  (3)
  • 1985-1989
  • 1975-1979
  • 1950-1954
Collection
Publisher
  • Springer  (3)
Years
  • 1990-1994  (3)
  • 1985-1989
  • 1975-1979
  • 1950-1954
  • 1995-1999  (1)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Computing 43 (1990), S. 199-207 
    ISSN: 1436-5057
    Keywords: 65C99 ; Particle methods ; linearized Boltzmann equation ; Gauss integration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Description / Table of Contents: Zusammenfassung In [3] ist eine Partikelmethode vorgestellt, die unendlich viele Partikel benötigt. Zu ihrer numerischen Implementierung muß der numerisch relevante Träger abgeschätzt werden. Um dies zu vermeiden, führen wir über die Gasß-Integration eine a priori endliche Form ein und stellen numerische Ergebnisse für verschiedene Testbereiche vor.
    Notes: Abstract In [3] a particle method is proposed which acts on an infinite grid. Hence, for a numerical application an estimation of the numerically relevant support is necessary. To overcome this difficulty we suggest a finite grid based on Gaussian integration formulas and present numerical results of different test examples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Planta 180 (1990), S. 147-153 
    ISSN: 1432-2048
    Keywords: Citrus ; Cuticle (composition, permeability) ; Humidity and cuticle permeability ; Temperature and cuticle permeability ; Wax (cuticle)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The water permeabilities of 3174 astomatous, isolated cuticular membranes from Citrus aurantium L. leaves were studied. Trees were grown in environmental chambers at temperatures ranging from 15 to 35° C and humidities of 50% and 90%. Photosynthetically active radiation was 500–1000 μmol photons·m−2· s−1. The different growing conditions had no effect on the water permeability of the membranes. However, storing isolated cuticular membranes at 8° C for up to 112 weeks decreased their water permeability, and it is argued that this is a consequence of the healing of defects between wax crystallites, and also indicates the dynamic nature of cuticular waxes.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of thermal analysis and calorimetry 38 (1992), S. 277-287 
    ISSN: 1572-8943
    Keywords: DSC ; limit of detection ; polymorphic transitions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Anhand von sehr kleinen Signalen von spontanen polymorphen übergängen bei CsCl, K2Cr2O7 und Na2SO4 wird ein Verfahren zur Bestimmung der Nachweisgrenze von DSC-Geräten beschrieben. Es wird gezeigt, wie derartige Signale gut aufgelöst in DSC-Diagrammen von Pulverproben erhalten werden können. Um sie vom Rauschen der Basislinie zu unterscheiden, sollten sie eine Höhe von mindestens dem Doppelten der Basislinienbreite aufweisen. Für das angewendete Gerät beträgt die entsprechende geringste Wärmemenge, d.h. die Nachweisgrenze 0.1 mJ.
    Notes: Abstract A procedure is described to determine the limit of detection of DSC instruments by using tiny signals from spontaneous polymorphic transitions of CsCl, K2Cr2O7 and Na2SO4. It is shown how such signals can be found well-resolved in DSC diagrams of powder samples. To distinguish them from the baseline noise they should exhibit a height at least twice that of the baseline width. For the instrument employed the corresponding smallest amount of heat, i.e., the limit of detection, was found to be 0.1 mJ.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...