ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of solid state electrochemistry 2 (1998), S. 427-431 
    ISSN: 1433-0768
    Keywords: Key words Polyindoline electrode ; Permselective membrane ; Permeation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A polyindoline permselective polymer film was readily synthesized by an electrochemical polymerization of indoline in an aqueous solution of KCl at a potential of 0.4 V vs Ag/AgCl. The amperometric responses of the polyindoline film-coated platinum electrodes to electroactive (ascorbic acid, oxalic acid and hydrogen peroxide) and non-electroactive (lactose, sucrose and urea) substances were measured at a potential of 0.7 V. Effects of various variables such as film thickness, concentrations of monomer and electrolyte, and pH on the permselective behavior of the polymeric membrane were systematically investigated and the optimal values were determined. It was found that permselective polyindoline-coated electrodes prepared in this one-step procedure permitted hydrogen peroxide oxidation while it prevented interference due to oxidizable species such as ascorbic acid and oxalic acid. As a result, it is believed that this polymeric membrane, owing to its permselective character, can be used as the protective material in the construction of hydrogen peroxide-based biosensors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 8 (1996), S. 571-574 
    ISSN: 1040-0397
    Keywords: Glucose ; Glucose oxidase ; Poly(p-aminophenol) ; Enzyme electrode ; Amperometric biosensor ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An amperometric biosensor for glucose based on a novel polymeric matrix is described. The sensor was prepared by electrochemical polymerization of p-aminophenol in the presence of glucose oxidase on Pt substrates in a KCl solution at a potential of 0.6 V (vs. Ag/AgCl). The chronoamperometric response of poly(p-aminopheno1)-glucose oxidase biosensor to hydrogen peroxide formed as the result of enzymatic reaction was measured at a potential of 0.7 V (vs. Ag/AgCl) in PBS solution. It was shown that a biosensor prepared by this one- step procedure has a linear range up to 6mM glucose, a response time less than 5 s and a lifetime around 15 days. The sensitivity of the electrode was superior to that of much publicized polypyrrole based glucose oxidase electrode. Also, the substrate selectivity of PAP/GOx electrode was tested for coexisting substances such as lactose, sucrose, urea, paracetamol, uric and ascorbic acid and no discernible anodic response was observed above the background current.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1998-10-07
    Print ISSN: 1432-8488
    Electronic ISSN: 1433-0768
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...