ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (20)
  • Capillary electrochromatography
  • 1995-1999  (23)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. S49 
    ISSN: 1612-1112
    Keywords: Capillary electrochromatography ; Electroosmotic flow ; Submicron silica beads ; Mixed mode phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Reversed-phase stationary phases based on porous silica beads in the range 0.2–3 μm have been prepared to study the dependency of electroosmotic flow (EOF) on particle diameter. Additionally, the influence of the mobile phase composition, i.e. organic modifier content, pH of buffer solution and concentration of buffer salt, on the magnitude of the electroosmotic flow velocity has been investigated. To perform separations in an aqueous acidic mobile-phase, mixed mode stationary phases containing both alkyl chains and strong cationexchange groups have been applied.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 49 (1999), S. S35 
    ISSN: 1612-1112
    Keywords: Capillary electrochromatography ; Packing materials ; Mixed-mode phase ; Active ingredients and preservatives in creams ; Cortisone derivatives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Capillary electrochromatography (CEC) is an analytical method of growing interest to the pharmaceutical industry. Because CEC is a combination of high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) it has the advantages of the high selectivity of HPLC and the high efficiency of CE. The capillaries can be packed with different packing materials. The mixed-mode phase consisting of a strong cation exchanger and alkyl chains on the silica surface has some advantages over conventional reversed-phase (RP) packing materials. In this article the authors describe the use of CEC to separate the active ingredients and preservatives in creams from different manufactures. On the basis of the high efficiency of CEC it was possible to develop one isocratic method for all the compounds in the different samples. The method was validated with regard to identification, reproducibility, linearity, limit of detection, and quantitation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 99-104 
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; Micellear electrokinetic chromatography ; Organic modifiers ; Naphthalene sulfonates ; Surface water ; Thermostatting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The production and use of naphthalene sulfonates can easily cause pollution of surface and other types of waters. In the present study, capillary electrophoresis in combination with UV absorption detection was used to separate 21 amino- and hydroxy-substituted naphthalene sulfonates which included multiple isomeric compounds. The influence of various parameters such as pH (which turned out to be extremely important), temperature of the surrounding air flow, and the use of buffer additives (micelles, cyclodextrins, organic modifiers) was studied. Complete separation of all analytes including the isomers, was achieved in two runs with a 50 mM boric acid/borate buffer, containing either 100 mM sodium dodecylsulfonate or 15% acetonitrile. The limits of detection obtained for the individual compounds typically were 20μgI-1. River water samples spiked at this concentration level could be analysed using a simple three-step sample clean-up procedure.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: On-line extraction ; Large volume introduction ; Capillary gas chromatography ; Atomic emission detection ; Solvent venting ; Pesticides ; Ground water ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The on-line coupling of a liquid-liquid extraction system with capillary gas chromatography using atomic emission detection (GC-AED) has been studied. The required large volumes of about 100 μl of an iso-octane solution can be introduced into the GC-AED system by using the AED solvent vent and a solvent vapor exit in front of the capillary analytical column. Test solutions containing several pesticides were detected using the carbon, chlorine, nitrogen and sulfur channels. Analyte detectability (in concentration units) was improved significantly and low concentractions of the test compounds could be determined (1-5 ng/ml). Aqueous samples were on-line extracted and analyzed. The precision of the large-volume injection itself as well as the total extraction-GC-AED system was satisfactory (RSD of ca. 2 and 4%, respectively). As a real-life application, several ground water samples were screened.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: Large-volume on-column injection ; gas chromatography ; infrared spectrometry ; microcontaminants ; solid-phase extraction ; open-split interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A large-volume on-column GC-cryotrapping-IR system was developed for injections of up to 100 μl of organic extracts. Considerable reduction of the solvent-and-water background and enhanced analyte detectability was achieved by using an open-split interface between the GC column and the IR detector and improving the leak-tightness of the system. The system was combined with solid-phase extraction to yield on-line SPE-GC-IR. With this set-up, sample volumes of only 20 ml sufficed to detect, and identify, microcontaminants in tap and surface water at the 0.1-1 μg/L level. Detection limits were on the order of 15 ng/L for tap water when using appropriate functional-group chromatograms. Or, in other words, SPE-GC-IR is a suitable technique for the screening of environmental water samples for functional groups, i.e. classes of compounds, of interest.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Capillary electrophoresis ; interfacing ; sample treatment ; serum ; solid-phase extraction ; sulfonamides ; urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 459-464 
    ISSN: 0935-6304
    Keywords: Fast gas chromatography ; gas chromatography ; resistive heating ; organophosphorus pesticides ; PAHs ; triazines ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed inside a metal tube which can be heated, and cooled, much more rapidly than any conventional GC oven. The EZ Flash assembly can generate temperature ramps up to 1200°/min and can be cooled down from 300 to 50°C in 30 s. Samples were injected via a conventional split/splitless injector and transferred to the GC column. The combination of a short column (5 m×0.25 mm i. d.), a high gas flow rate (up to 10 mL/min), and fast temperature programmes typically decreased analysis times from 30 min to about 2.5 min. Both the split and splitless injection mode could be used. With n-alkanes as test analytes, the standard deviations of the retention times with respect to the peak width were less than 15% (n = 7). First results on RSDs of peak areas of less than 3% for all but one n-alkane indicate that the technique can also be used for quantification. The combined use of a short GC column and fast temperature gradients does cause some loss of separation efficiency, but the approach is ideally suited for fast screening as illustrated for polycyclic aromatic hydrocarbons, organophosphorus pesticides, and triazine herbicides as test compounds. Total analysis times - which included injection, separation, and equilibration to initial conditions - were typically less than 3 min.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 69-79 
    ISSN: 0935-6304
    Keywords: Large volume injection ; PTV injector ; Water analysis ; River sediment ; Pesticides ; Polycyclic aromatic hydrocarbons (PAHs) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Temperature programmable (PTV) injectors with packed widebore (ca. 3.5 mm i.d.) liners are used for large volume injection in capillary gas chromatography with the aim to simplify and/or improve off-line sample pretreatment proecdures. A simple procedure for optimization of large volume PTV injection is described. The system performance, i.e. linearity and repeatability, is evaluated for polar nitrogen/phosphorus containing pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water extracts as well as for polycyclic aromatic hydrocarbons (PAHs) in river sediment (PTV-GC-MS).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0935-6304
    Keywords: LC-GC ; Partially concurrent solvent evaporation ; Organochlorines ; PCBs ; Fatty matrices ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Off-line normal-phase LC has been used for the clean-up of compounds in our laboratory for several years. On-line coupling of this LC system, which typically yields 12 ml fractions, is not possible due to its large fraction volume. The maximum transfer volume in on-line LC-GC/ECD is approx. 300 μl. Therefore down-scaling of the LC system was attempted in order to reach these low fraction volumes. Miniaturization resulted in a 240 μ1 LC fraction containing the analytes of interest, which is transferred to GC/ECD via an on-column interface. Sensitivity requires that a minimum amount equivalent to 1-2 mg of sample should reach the GC detector; the selectivity is determined by the separation between the matrix and the last eluting target analyte.For the analysis of fatty samples, limitations were observed in the separation of dieldrin from triglycerides. Other organochlorine compounds, e.g. polychlorobiphenyls (PCBs), the DDT group, HCB and the HCHs can be analyzed with RSDs of 2-4 % (n = 10) at concentration levels of sub-μ/kg in milk fat using a 3 μm Hypersil silica 50 × 1.0 mm i.d. LC column.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0935-6304
    Keywords: Capillary GC ; Continuous liquid-liquid extraction ; Environmental applications ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability of a liquid-liquid extraction system which is coupled on-line with a capillary gas chromatograph was studied for environmental and ecotoxicological analyses. The optimized and automated system was used for the determination of apolar and rather non-volatile organic compounds in aqueous samples. Relevant aspects of sample introduction, phase separation and selection of extraction solvent are discussed. Three routine-tipe applications are described, viz. an improved method for the determination of hexachlorocyclohexanes in ground water and the determination of the so-called NCC-ether and ACC-ether in ecotoxicological studies. Depending on the application studied, the concentration levels varied from 0.1 to 6000 μg/I, using ECD and/or FID detection. Typical coefficients of variation obtained with the total extraction-GC procedure were 2-25%.The system was found to be rugged, it saves time compared with set-ups involving off-line liquid-liquid extraction and considerably reduces the manual work load.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...