ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (4)
  • Polymer and Materials Science  (4)
  • 1995-1999  (4)
  • 1970-1974
  • Chemistry and Pharmacology  (3)
  • Medicine  (1)
  • Mathematics
Collection
  • Articles  (4)
Publisher
Years
Year
Topic
  • Chemistry and Pharmacology  (3)
  • Medicine  (1)
  • Mathematics
  • Technology  (1)
  • 1
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 39 (1996), S. 615-618 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 7 (1995), S. 247-250 
    ISSN: 1040-0397
    Keywords: Uranium ; Sensor ; Remote sensing ; Field screening ; Modified electrode ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A carbon paste electrode modified with the ligand propyl gallate is introduced for preconcentration/voltammetric measurements of low levels of uranium. The resulting preconcentrating electrode offers many attractive properties for on-site sensing of uranium, including high sensitivity and selectivity, self-cleaning capability, and use of nondeaerated quiescent solutions. The response is characterized with respect to the paste composition, preconcentration period, solution and differential pulse conditions, and other variables. The sensor displays high stability, and can be used repeatedly without regeneration. When coupled to a 100-ft (30.5-m) long shielded cable, the electrode offers a remote sensing capability, as illustrated in the determination of uranium in groundwater.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 8 (1996), S. 443-446 
    ISSN: 1040-0397
    Keywords: Glucose ; Composite electrodes ; Pulsed amperometry ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Segregated composite electrodes mimic microelectrode ensembles. In this preliminary report, the use of a rotating gold-polychlorotri- fluoroethylene (or Kel-F, a 3M Company polymer) composite electrode in combination with pulsed amperometric detection (PAD) is described for the detection of glucose. Comparisons are made with results obtained at a solid gold disk electrode. The composite electrode exhibits a higher signal and a lower background than does the solid gold electrode. In terms of current density, the enhancement of the signal above the background is over 3-fold, similar to that observed with segregated graphite composite electrodes used in a constant potential mode. Little or no glucose signal is observed at either the solid gold or the gold composite electrode when employed in the constant potential mode. In the PAD mode, the signal is stable for periods in excess of an hour.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 41 (1998), S. 649-656 
    ISSN: 0021-9304
    Keywords: flow cytometry ; cell culture ; biocompatibility ; biomaterials ; implants ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Flow cytometry (FCM) was examined as a possible procedure for measuring in vitro the biocompatibility of implant materials for orthopedic and dental surgery. The human osteoblast-like cell line MG63 was grown on hydroxyapatite (HA) and P2O5 glass-reinforced HA composite discs and compared with the same cells grown on polystyrene culture dishes. While morphological observation at the light and electron microscopic levels showed no major deleterious effects, FCM indicated that cell size was somewhat reduced, particularly by growth on the HA composite. Moreover, this material also appeared to delay the progression of the cells from the G0/G1 into the S phase of the cell cycle. In addition to this low level of inhibition of cell growth relative to control cultures, FCM analysis also demonstrated that the glass-reinforced HA caused some down-regulation of the expression of osteocalcin and fibronectin, two antigens which play a vital part in the integrity and function of bone and soft connective tissue, respectively. These results thus show, first, that although HA and the HA composite used in these experiments were generally biocompatible, they nevertheless had certain suboptimal effects on the cells; and second, that FCM could be a highly useful procedure for effectively screening and evaluating important biological responses to implant materials. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 649-656, 1998.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...