ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-07-13
    Description: The data reduction procedures and programs for analysis of the IMP F and G energetic particle flux experiments are summarized. The IMP-F experiment contained two thin-window Geiger-Mueller detectors and an ionization chamber. There were two IMP-G experiments: one with six Geiger-Mueller detectors and an ionization chamber, and the other with two funnel mouthed channeltrons in a parallel plate electrostatic analyzer. These experiments measured particles in the energy range above 20 keV (IMP-F) and above approximately 5 keV (IMP-G). A bibliography is presented of papers containing the scientific results. These data were predominantly used for the study of low energy solar particles from flares.
    Keywords: PHYSICS, ATOMIC, MOLECULAR, AND NUCLEAR
    Type: NASA-CR-132869 , SSL-SER-14-ISSUE-19
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-07-13
    Description: The technical aspects of the University of California IMP-F experiment aboard the Explorer-34 and the University of California IMP-G (S1) and (S2) experiments aboard the Explorer-41. The experiment detectors and electronics are discussed for each experiment as well as the fabrication, preflight and post-flight history. A description of the ground support equipment is also given for each experiment. These three experiments were essentially all different. The IMP-G experiment was essentially the IMP-F experiment with the addition of four Geiger-Mueller detectors. The IMP-G (S-2) was a supplementary experiment and differed completely from the IMP-F and IMP-G experiments. It was concluded that the ground support equipment approach used for the IMP-F and IMP-G experiments where emphasis was placed on a thorough exercise and monitoring of the experiment operation during various testing phases provided a high degree of confidence and reliability in these experiments. No known electronic failures have occurred during the spacecraft lifetime although some detector problems were experienced.
    Keywords: PHYSICS, ATOMIC, MOLECULAR, AND NUCLEAR
    Type: NASA-CR-130172
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...