ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • AERODYNAMICS  (498)
  • Life and Medical Sciences  (437)
  • INSTRUMENTATION AND PHOTOGRAPHY
  • 1995-1999  (257)
  • 1975-1979  (871)
  • 1955-1959  (53)
  • 1940-1944  (40)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Molecular Reproduction and Development 41 (1995), S. 435-448 
    ISSN: 1040-452X
    Keywords: Peri-implantation embryogenesis ; Trophoblast cells ; Recombinant proteins ; Integrins ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: To investigate the mechanism of trophoblast adhesion to fibronectin, we cultured blastocysts in serum-free medium on proteolytic fibronectin fragments containing its major functional domains, and localized fibronectin-binding integrins in outgrowing trophoblast cells by immunofluorescent staining. Outgrowth comparable to that obtained with intact fibronectin was observed using a 120 kD chymotryptic fragment containing the central cell-binding domain (FN-120) and the Arg-Gly-Asp (RGD) recognition sequence. A 40 kD COOH-terminal chymotryptic fragment of fibronectin containing both a heparin-binding region and an alternate (non-RGD) cell-binding site was inactive in supporting trophoblast adhesion. Three synthetic peptides derived from the heparin-binding domain, including the CS1 alternate cell-binding site, were also unable to promote trophoblast cell adhesion. A 75 kD recombinant protein, ProNectin F, containing 13 copies of the cell recognition epitope of fibronectin, Val-Thr-Gly-Arg-Gly-Asp-Ser-Pro-Ala-Ser, vigorously supported blastocyst outgrowth. Blastocyst outgrowth was not significantly different when surfaces were precoated with cellular fibronectin, which contains an alternatively spliced type III repeat and is the form actually encountered in vivo. Several putative fibronectin receptors were localized in trophoblast outgrowths by immunofluorescent labeling. Antibodies reactive with integrin subunits α3, α5, αllb, αv, β1 and β3, but not α4, all bound to trophoblast cells. Antibodies raised against either the β1 or β3 integrin subunits significantly inhibited fibronectin-mediated outgrowth. These findings demonstrate the key role of the central cell-binding domain of fibronectin in trophoblast adhesion, and suggest four RGD-binding integrins, α3β1, α5β1, αllbβ3, and αvβ3, that could mediate trophoblast adhesion in vitro and may play an important role during implantation. © 1995 Wiley-Liss, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1040-452X
    Keywords: EGF-like ligands ; Postnatal development ; RT-PCR ; Immunocytochemistry ; Immunoblotting ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: Amphiregulin (Ar) and Cripto-1 (Cr-1) are growth promoting peptides that share amino acid sequence homology with epidermal growth factor (EGF). The present study examined Ar and Cr-1 mRNA and protein expression during various stages of C57BL/6 mouse mammary morphogenesis. Reverse transciption-polymerase chain reaction (RT-PCR) was used to detect transcripts for Ar and Cr-1 at all stages of mammary development. Immunocytochemical (ICC) localization demonstrated that in virgin 4-week to mature 12-week-old mouse fourth inguinal mammary gland, Ar and Cr-1 are expressed in the stromal cells, luminal epithelial cells, and myoepithelial cells of the branching ducts. Ar, and to lesser extent Cr-1, were also found in the epithelial cap cells and in the luminal epithelial cells of the advancing terminal end bud (TEB) from virgin 4-week and 6-week-old mice. Western blot analysis demonstrated that both Ar (28 and 26 kDa) and Cr-1 (90, 67, 56, and 21 kDa) proteins are expressed in virgin, 13.5 day midpregnant and in the 14 day lactating mammary gland. In addition, Ar and Cr-1 are associated with developing alveolar structures as determined by ICC. These results imply that together with EGF and transforming growth factor alpha (TGFα), Ar and Cr-1 may play salient roles as modifiers in the morphogenesis and differentiation of the mammary gland. © 1995 Wiley-Liss, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0095-9898
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0095-9898
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 16 (1995), S. 70-74 
    ISSN: 0197-8462
    Keywords: video display terminals ; embryogenesis ; teratology ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Eighty-nine Swiss Webster mice were randomly divided into four groups: a control group, a pulsed magnetic field (PMF) group, a cytosine arabinoside (ara-C, a teratogen) group, and, a combined PMF + ara-C group. Mice in the PMF and PMF + ara-C groups were irradiated with a PMF (a sawtooth waveform with 52 μs rise time, 12 μs decay time, and 15.6 kHz frequency) at a peak magnetic flux density of 40 μT for 4 hours daily on days 6-17 of gestation. The mice in the ara-C and the PMF + ara-C groups were injected intraperitoneally on day 9 of gestation with 10 mg/kg of ara-C. The incidence of resorption and dead fetuses was not affected by PMF but was increased by ara-C injection. The malformation incidence of cleft palate (CP) and/or cleft lip (CL) was significantly higher in all three of the treated groups than in the control group (P 〈 0.05). If, however, statistical analyses had been done on litters rather than on individual fetuses, they would show that the incidence of CP and/or CL in the PMF group is not significantly greater than that in the control group. A significantly higher incidence of CP and/or CL was found in the PMF + ara-C group (49%) than the ara-C alone group (26.1%). These data suggest that PMF might enhance the development of ara-C-induced CP and/or CL. The incidence of minor variations in skeletal development, including reduction of skeletal calcification and loss of skeleton, was not statistically significant in the PMF group. However, it was higher in the two ara-C-treated groups, and there was no significant difference between the ara-C alone group and the ara-C + PMF group. From these results it is concluded that the very weak embryotoxic effects of PMF exposure may be revealed and enhanced in combination with a teratogenic agent. © 1995 Wiley-Liss, Inc.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-17
    Description: Described in detail is a laser induced fluorescence system which has been successfully interfaced with two aircraft sampling platforms (i.e., Sabreliner jet and an L-188C Electra). This system, which has been under development for four years, presently consists of the following major components: (1) a Nd-Yag laser driven oscillator-amplifier dye laser; (2) a sampling manifold with associated fluorescence detection optics; (3) an OH calibration chamber; (4) a laser beam steering assembly; and (5) sampling electronics and data processing hardware. During the last three years, this system has been flown some 50,000 air miles making tropospheric OH radical measurements over the latitude range of 70 N to 57 S. OH concentrations measured during these flights have ranged from 30 parts-per-quadrillion (3.7 x 10 to the 5th molecules/sq cm) at altitudes of 6 km to 0.8 parts-per-trillion (2.0 x 10 to the 7th molecules/sq cm) at 0.5 km. Computations have been completed which indicate that the existing aircraft system with modest modifications should also be capable of detecting natural tropospheric levels of NO, SO2, CH2O, NO2, HNO2, NO3, H2O2 and CS2 by using both conventional laser-induced fluorescence methodology and multiphoton techniques.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 50; Dec. 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2016-06-07
    Description: The status of an investigation of four numerical techniques for the time-dependent compressible Navier-Stokes equations is presented. Results for free shear layer calculations in the Reynolds number range from 1000 to 81000 indicate that a sequential alternating-direction implicit (ADI) finite-difference procedure requires longer computing times to reach steady state than a low-storage hopscotch finite-difference procedure. A finite-element method with cubic approximating functions was found to require excessive computer storage and computation times. A fourth method, an alternating-direction cubic spline technique which is still being tested, is also described.
    Keywords: AERODYNAMICS
    Type: Aerodynamic Analyses Requiring Advanced Computers, Pt. 1; p 437-468
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2017-10-02
    Description: As a further demonstration of the capabilities of laser velocity in compressible aerodynamics, measurements obtained in a Mach 2.9 separated turbulent boundary layer and in the transonic flow past a two-dimensional airfoil section are presented and compared to data realized by conventional techniques. In the separated-flow study, the comparisons were made against pitot-static pressure data. Agreement in mean velocities was realized where the pressure measurements could be considered reliable; however, in regions of instantaneous reverse velocities, the laser results were found to be consistent with the physics of the flow whereas the pressure data were not. The laser data obtained in regions of extremely high turbulence suggest that velocity biasing does not occur if the particle occurrence rate is low relative to the turbulent fluctuation rate. Streamwise turbulence intensities are also presented. In the transonic airfoil study, velocity measurements obtained immediately outside the upper surface boundary layer of a 6-inch chord MACA 64A010 airfoil are compared to edge velocities inferred from surface pressure measurements. For free-stream Mach numbers of 0.6 and 0.8, the agreement in results was very good. Dual scatter optical arrangements in conjunction with a single particle, counter-type signal processor were employed in these investigations. Half-micron-diameter polystyrene spheres and naturally occurring condensed oil vapor acted as light scatterers in the two respective flows. Bragg-cell frequency shifting was utilized in the separated flow study.
    Keywords: AERODYNAMICS
    Type: AGARD Appl. of Non-Intrusive Instr. in Fluid Flow Res.; 12 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: Measurements obtained with laser velocimetry in a Mach 2.9 separated turbulent boundary layer and in the transonic flow past a two-dimensional airfoil section are presented and compared to data realized by conventional techniques. Agreement in mean velocities was realized where the pressure measurements could be considered reliable; however, in regions of instantaneous reverse velocities, the laser results were found to be consistent with the physics of the flow whereas the pressure data were not. Streamwise turbulence intensities are also presented. In the transonic airfoil study, velocity measurements obtained immediately outside the upper surface boundary layer of a 6-inch chord NACA 64A010 airfoil are compared to edge velocities inferred from surface pressure measurements. For free-stream Mach numbers of 0.6 and 0.8, the agreement in results was very good. "Dual scatter" optical arrangements in conjunction with a single particle, counter-type signal processor were employed in these investigations.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA-TM-X-73117 , A-6510
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: The response of a tungsten-scintillator ionization spectrometer to accelerated particle beams has been investigated. Results obtained from exposure of the approx. 1000 g/sq cm apparatus to 5, 10, and 15 GeV/c electrons and pions as well as to 2.1 GeV/nucleon C-12 and O-16 ions are presented. These results include cascade-development curves, fractions of the primary energy measured by the spectrometer, and resolutions of the apparatus for measuring the primary energies. For 15 GeV/c electrons, an average of about 82% of the incident energy is measured by the apparatus with resolution (normal standard deviation) of about 6%. For 15 GeV/c pions, an average of about 65% of the incident energy is measured with resolution of about 18%. The energy resolution improves with increasing energy and with increasing depth of the spectrometer.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Nuclear Instruments and Methods; 126; 1975
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...