ISSN:
1089-7623
Source:
AIP Digital Archive
Topics:
Physics
,
Electrical Engineering, Measurement and Control Technology
Notes:
Compact, vacuum-compatible submillimeter viewing dumps, whose design parameters were based on the results of simple ray calculations, have been fabricated from Pyrex, Macor, and alumina. The measured performance of the dumps agrees qualitatively with calculated results. The absorption is somewhat lower than expected, but still acceptable (≥99% absorption for Pyrex and Macor). In an electron cyclotron plasma emission experiment on Alcator C tokamak, comparison of the emission spectra with and without the dump shows that the dump in this configuration is effective in suppressing the unwanted radiation by approximately 90%. The additional reflection is believed to be due to a portion of the antenna pattern missing the dump.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.1138635
Permalink