    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 403-408 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cryogenic trapping ; Capillary ; Focusing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Cryogenic trapping of solutes leads to narrowing of the chromatographic band. By placing the trap at the end of a capillary column, it is possible to study the effectiveness of the trap in terms of producing a sharpened elution profile. The trap may be heated by supplementary heating, but here convective heating from the GC oven is employed simply by turning off the cryogenic coolant. It is estimated that it takes about 50 s for the trap to heat up sufficiently to allow trapped solute to be remobilized, although this depends upon the oven temperature and thermal mass of the trap. It can also be shown that the more volatile solutes mobilize faster from the trap in this particular mode of operation. The recovery of trapped components shows that there is essentially quantitative trapping, and the solutes are trapped just at the leading edge of the trap.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 620-622 
    ISSN: 0935-6304
    Keywords: Multidimensional gas chromatography ; comprehensive two-dimensional gas chromatography ; kerosene analysis ; cryogenic modulation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 235-238 
    ISSN: 0935-6304
    Keywords: Cryogenic modulation ; LMCS ; GC×GC ; multidimensional GC ; comprehensive gas chromatography ; petroleum analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: No abstract
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 622-626 
    ISSN: 0935-6304
    Keywords: Multidimensional capillary chromatography ; Polychlorinated biphenyls ; PCBs ; Congener ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Multidimensional chromatography was used to resolve the specific chlorobiphenyl (CB) congeners 28, 52, 101, 118, 138, 153, and 180 in technical aroclor standards. Single column analysis of polychlorinated biphenyls (PCBs) results in co-elution of key congeners with other components in the mixture; therefore using two columns of different selectivity was necessary to enhance the resolution achievable on just one column. The HT8 column (8% phenylpolycarborane-siloxane phase) has been reported to have specific selectivity characteristics for improved PCB separation. When coupled with a BPX5 column (5% phenylpolysiloxane-silphenylene phase), it has been shown here to provide unambiguous identification of 7 marker compounds which are used to monitor PCB occurrence and distribution. All seven marker CBs are present in aroclor 1254, and by adjusting the size of the heartcut window, it was possible to obtain resolution of the marker congeners from other congeners. Single column analysis is unable to achieve this result. This offers an alternative to GC-MS analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 921-923 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A method is described for the rapid analysis of mixtures of porphyrin methyl esters using laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS). Ions corresponding to [M+H]+ for each component have been observed without the need for added matrix. LDI-TOF MS has been applied to the analysis and characterization of porphyrin methyl esters derived from urine samples of patients suffering from various porphyrias. This technique has been shown to provide ‘fingerprint’ profiles of the porphyrins present in each urine sample, characteristic of the porphyria, which compare favourably with those obtained with the established method of high-performance liquid chromatography. LDI-TOF MS is a rapid and reliable method for the screening of urine from patients suffering from porphyria.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 32-38 
    ISSN: 0935-6304
    Keywords: LMCS ; column bleed ; modulation ; signal enhancement ; capillary GC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A Longitudinally Modulated Cryogenic System (LMCS) was evaluated for its use in detection enhancement in capillary gas chromatography. The mechanism for chromatographic re-elution for the LMCS is substantially different to other cryogenic devices. The cooled region of the capillary column in which chromatographic bands may be focused is heated by the surrounding oven temperature either by moving the trap along the column, or by moving the column out of the trap. By continually modulating the LMCS at the detector end of the capillary column, signal-to-noise ratios of routine chromatograms can be readily increased by a factor of ten, thus enhancing chromatographic detection. Base widths of peaks, which are often about 2-3 s or more can be easily reduced to 0.3 s when the LMCS is employed in the detection enhancement mode, thus offering a simple avenue to improved peak height sensitivity in capillary gas chromatography.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0749-1581
    Keywords: Through-space coupling ; Tetrahydroindazoles ; Protoporphyrinogen oxidase ; Molecular mechanics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 1H, 13C and 19F NMR experiments for a series of 3-alkyl-2-phenyl-4,5,6,7-tetrahydroindazoles revealed a six-bond through-space coupling between the ortho-fluorine and the hydrogen or fluorine atom of the position 3-alkyl group. This was further supported by NOE experiments. Molecular mechanics calculations on a representative structure indicated that several low energy conformers met the fluorine-carbon distance constraint suggested by the NMR data, and dynamic annealing experiments produced a conformer which was in complete agreement with the NMR data. This through-space interaction is speculated to be a result of repulsion between N-1 of the tetrahydroindazole and the ortho-fluorine lone pair electrons.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource