ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 157 (2000), S. 407-433 
    ISSN: 1420-9136
    Keywords: Key Words: Continuous radon monitor prototype, review of methods, seismic, volcanic and environmental surveillance.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract —A “quasi continuous mode” monitoring system to measure the radon concentration within a natural environment (mainly groundwater), was designed, assembled and tested, under collaboration between DINCE and ING, partly within the framework of two EC funded programs.¶The radon monitor consists of a customised discrete automatic sampler which produces a gas flux circuit, and an economical α-scintillation cell, coupled with a reliable electronics-photomultiplier assemblage. A convenient calibration system together with a temporised control system have been set up. The overall “mean efficiency” of the system was calculated to be 7.79±0.13 counts per minute (cpm) for each Bq/L.¶Taking into consideration the present and future requirements of a geochemical surveillance network to assess natural hazards, the prototype design evolved from the study of existing systems devoted to monitor radon concentration levels, which are critically reviewed within this paper.¶In response to the main prerequisite of a remote station: maximum remote sensor versatility preserving shared software and hardware for the network as a whole, this radon monitoring system was conceived as part of a multi-parametric Geochemical Monitoring System (GMS II) prototype, designed and realised as a test-stand for sensors (chemical, hydrological, geophysical, organic chemistry devoted, etc.) in continuous evolution throughout the international market.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-157X
    Keywords: Apennines-Central Italy ; earthquake chemistry-isotope chemistry ; fluids behaviour-seismicity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract After the earthquakes of September 26, 1997, that hit the Umbria-Marcheboundary (Apennine, Central Italy), with a maximum 6.0 Mw, aprogram of geochemical surveying together with a collection ofhydrogeological changes episodes was extended throughout theepicentre-area, taking the yearly period of the seismic sequence as a whole.After a first areal screening, the Bagni di Triponzo thermal spring wasselected for a discrete temporal monitoring (weekly and monthly basis),being the unique thermal spring throughout the epicentre area. This sitedeserves peculiar interest in deepening the knowledge about deep fluidscirculation changing during seismicity.Laboratory and on-field analyses included major, minor and trace elementsas well as dissolved gases (He, Ar, CH4, CO2, H2S,222Rn, NH4, As, Li, Fe, B, etc...) and selected isotopic ratios(C, H, O, He, Sr, Cl), meaningful from tectonic point of view.The chemistry and isotopic chemistry of the spring were fully outlined anddiscussed, pointing out the main process involving the thermal aquifer: thewater-rock interaction inside the Evaporite Triassic Basement (ETB),possibly involving also the Paleozoic Crystalline Basement. On theother hand, sudden and apparent geochemical and hydrogeologicalvariations during the seismic sequence ruled out an evolution in thewater-rock interaction processes. They occurred both at depth, i.e.,induced by fluid remobilization within the crust explained by the Coseismic Strain Model and by the Fault Valve Activity Model, and in the shallow part of the reservoir (i.e., meteoric watercontamination). A statistical multivariable analysis (Factor Analysis) wasaccomplished to better constrain the correlation between the paroxysmalphases of the seismic sequence and the observed trends and spike-likeanomalies. The groundwater variations was inferred to occur mainly insidethe ETB, from depth (1–2 km) up to surface, particularly in associationof the Sellano earthquake (14/10/1997) and of the seismic re-activationof the sequence at the end of March 1998 (Gualdo Tadino-Rigali andVerchiano areas). The lack of deeper input from below the ETB (slightsignature of PCB), as the lack of He mantle signature, during the seismicperiod as a whole, accounted for seismogenic fault segments rooted onlyin the crust. The results also provide useful information about theearthquake-related response mechanisms occurring at this site, thatrepresent the basic task for planning and managing the impendinghydro-geochemical network aimed at defining the relationships betweenseismic cycle, fluids and reliable earthquake forerunners.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
  • 4
    Publication Date: 2003-08-31
    Description: The paper discusses the correlation between the heating of shallow groundwater over a 10 × 20 km wide area close to the town of Nizza Monferrato (Piemonte Region, Northern Italy) and the concomitant local seismic sequences during the period August 2000 – July 2001. The first seismic sequence started on 21 August 2000 with a Ml = 5.2 earthquake. Within few hours, the local authorities received calls alerting that the groundwater temperature rose from 10 to 30°C in many shallow wells. Our geochemical experimental data and the geological-seismotectonic framework do not allow the hypothesis of simple fluid mixing between the thermal reservoir of Acqui Terme and the Nizza-Monferrato shallow groundwater to explain the observed thermal anomalies. On the other hand, we invoke more complex processes such as frictional heating, mechano-chemistry, fault-valve mechanism, adiabatic decompression and hydrogeologically driven heat flow i.e., thermal effects due to variations of basin-scale permeability field. All these processes are able to transmit heat to the surface and to generate a transient incremental heat flow better than the mass transfer occurring typically when fluids from different reservoirs mix.
    Print ISSN: 1561-8633
    Electronic ISSN: 1684-9981
    Topics: Geography , Geosciences
    Published by Copernicus on behalf of European Geosciences Union.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2004-07-01
    Description: Five large earthquakes shook southern Calabria in February-March 1783. We focused on the first shock (Me 6.9), which occurred on 5 February in the Gioia Tauro Plain. Most investigators attribute the event to a W-dipping, high-angle fault running at the base of the Aspromonte crystalline bedrock on the ESE side of the Plain (Aspromonte Fault). Other workers contend that the earthquake was generated by an E-dipping, low-angle blind fault (Gioia Tauro Fault) similar to the adjacent Messina Straits Fault. In 1999-2000 we carried out four geochemical surveys in the Gioia Tauro Plain with the aim of contributing to this debate with an independent line of evidence. We sampled 240 groundwater sites and measured a suite of in-situ physical and chemical parameters. Our goal was to gain new insight into the seismogenic source by identifying geochemical anomalies associated with the deepening of the hydrological circuits due to the presence of enhanced faulting/fracturing. The deep-fluid signatures are mainly represented by temperature, salinity, total carbon and radon anomalies. We identified three zones of dominant deep fluid discharge: the Nicotera-Galatro area (along the Nicotera-Galatro portion of the NW-trending Nicotera-Gioiosa Jonica lineament), a small NW-SE trending area between Gioia Tauro and Seminara, and the coastline between Rosarno and Palmi. This latter sector locates just above the upper edge of the hypothesised Gioia Tauro Fault. Most of the geochemical anomalies are recorded around Rosarno, at the intersection between the Gioia Tauro Fault and the Nicotera-Gioiosa Jonica lineament. In contrast, no evidence of groundwater deepening and active fracturing was found along the Aspromonte Fault. Based on our new findings we updated the concepts of Geochemically Active Fault Zone and Geochemical Interaction Fault Zone in view of the modern understanding of the hydro-mechanical properties of fault zones and the faulting mechanisms promoting fracture permeability in the crust. © 2004 Kluwer Academic Publishers.
    Print ISSN: 1383-4649
    Electronic ISSN: 1573-157X
    Topics: Geosciences , Physics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2000-01-01
    Description: After the earthquakes of September 26, 1997, that hit the Umbria-Marche boundary (Apennine, Central Italy), with a maximum 6.0 Mw, a program of geochemical surveying together with a collection of hydrogeological changes episodes was extended throughout the epicentre-area, taking the yearly period of the seismic sequence as a whole. After a first areal screening, the Bagni di Triponzo thermal spring was selected for a discrete temporal monitoring (weekly and monthly basis), being the unique thermal spring throughout the epicentre area. This site deserves peculiar interest in deepening the knowledge about deep fluids circulation changing during seismicity. Laboratory and on-field analyses included major, minor and trace elements as well as dissolved gases (He, Ar, CH4. CO2, H2S. 222Rn, NH4, As, Li, Fe, B, etc...) and selected isotopic ratios (C, H, O, He, Sr, Cl), meaningful from tectonic point of view. The chemistry and isotopic chemistry of the spring were fully outlined and discussed, pointing out the main process involving the thermal aquifer: the water-rock interaction inside the Evaporite Triassic Basement (ETB), possibly involving also the Paleozoic Crystalline Basement. On the other hand, sudden and apparent geochemical and hydrogeological variations during the seismic sequence ruled out an evolution in the water-rock interaction processes. They occurred both at depth, i.e., induced by fluid remobilization within the crust explained by the Coseismic Strain Model and by the Fault Valve Activity Model, and in the shallow part of the reservoir (i.e., meteoric water contamination). A statistical multivariable analysis (Factor Analysis) was accomplished to better constrain the correlation between the paroxysmal phases of the seismic sequence and the observed trends and spikelike anomalies. The groundwater variations was inferred to occur mainly inside the ETB, from depth (1-2 km) up to surface, particularly in association of the Sellano earthquake (14/10/1997) and of the seismic re-activation of the sequence at the end of March 1998 (Gualdo Tadino-Rigali and Verchiano areas). The lack of deeper input from below the ETB (slight signature of PCB), as the lack of He mantle signature, during the seismic period as a whole, accounted for seismogenic fault segments rooted only in the crust. The results also provide useful information about the earthquake-related response mechanisms occurring at this site, that represent the basic task for planning and managing the impending hydro-geochemical network aimed at defining the relationships between seismic cycle, fluids and reliable earthquake forerunners.
    Print ISSN: 1383-4649
    Electronic ISSN: 1573-157X
    Topics: Geosciences , Physics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2020-02-12
    Keywords: 550 - Earth sciences
    Type: info:eu-repo/semantics/conferenceObject
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2020-02-12
    Keywords: 550 - Earth sciences
    Type: info:eu-repo/semantics/article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...