Publikationsdatum:
2016-06-07
Beschreibung:
For qualitative analysis of atmospheric particulates by microscopy, the sampling device should preserve the particles in the state existing at the moment of capture. A collector is described that uses electrostatic precipitation to capture and disperse specimens on various substrates for direct insertion into microscopes. Sampling runs in various atmospheres are described. Micrographs are presented to show particle morphology and distribution on the substrates. Chemical identification by X-ray energy probe and electron diffraction is illustrated.
Schlagwort(e):
ENVIRONMENT POLLUTION
Materialart:
NASA. Goddard Space Flight Center Ninth Conf. on Space Simulation; p 267-275
Format:
application/pdf
Permalink