ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (16)
  • 11-50 min migration time for linear TLC, 50 mm height  (1)
  • 42.75
  • Monocytes
  • Wiley-Blackwell  (16)
  • 2000-2004  (2)
  • 1975-1979  (14)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 97-97 
    ISSN: 0935-6304
    Keywords: Liquid Chromatography ; Structure and relation of polyhalogenated aromatics ; discussed ; Silica gel/aluminium oxide compared ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Separation of polychloro biphenyls ; Separation of organochlorine pesticides ; Splitless automated injection ; Residue level ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Complicated PCB mixtures can be separated in individual compounds using glass capillary gas chromatography, (GC)2. Depending on extraction and clean-up procedure it is also possible to separate and determine organochlorine pesticides at the same time.This (GC)2 technique can be used to determine the contents of individual chlorinated biphenyls in milk products and animal feedstuffs and in the analysis of complicated extracts of soil and vegetable material.Practical aspects concerning connection of the capillary, automatic splitless injection, repeatability of the retention time, quality of the column with respect to separation and adsorption and degradation of DDT are discussed.The detection of individual chlorinated biphenyls is possible at the ppb level in fats and vegetable materials, using an extraction and clean-up procedure, based on saponification of the sample.Preliminary results for milk, obtained from several areas, are shown.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Comprehensive two-dimensional gas chromatography ; thermal desorption modulator ; temperature programming ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---In comprehensive two-dimensional gas chromatography, two individual separations are coupled by means of a rotating thermal desorption modulator interface. The injection pulse introduced via the interface onto the second column should be as short as possible. Parameters affecting the modulator operation are studied. In the set-up used in this study, the temperature of the second column can be programmed independently from that of the first column. Optimization of the second-dimension separation to minimize peak broadening and maximize resolution is discussed and an elegant approach to determine second-dimension retention times using a non-constant modulation frequency is demonstrated. The high separation power of the comprehensive system is demonstrated by the analysis of technical and biota samples containing chlorinated biphenyls and toxaphene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 79-81 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography TLC ; Chemically bonded C8 on precoated HPTLC plates tested 6 dialcylphthalates used as test substances ; 15-20% (v/v) water in organic solvents, upper practical limit as mobile phase composition ; 11-50 min migration time for linear TLC, 50 mm height ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 4 (1977), S. 310-316 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mass spectra and gas chromatographic properties of 17 synthetic fluoro-, chloro- and Bromomethoxybiphenyls and 12 dichlorodimethoxybiphenyls have been examined. From this representative series it appears that the position of the methoxy group (ortho, meta and para to the biphenyl bond) in all monomethoxy compounds examined, and the positions of the two methoxy groups in most of the dimethoxy compounds, can be assigned unambiguously by their difference in fragmentation pattern. The value of this method was shown by metabolism experiments in which 4,4′-difluoro- and 4,4′-dibromobiphenyl were fed to rats and 4,4′-dichlorobiphenyl was administered to plants. All hydroxylated metabolites found were identified by gas chromatography mass spectrometry. Relationships between structure and gas chromatographic retention time of these compounds are discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0935-6304
    Keywords: μLC ; FID ; LC-FID ; carbohydrates ; amino acids ; alcohols ; phosphonic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The potential of the on-line coupling of microcolumn liquid chromatography (μLC) using aqueous eluents with a flame ionization detector (FID) was evaluated. An eluent-jet interface was modified to allow the efficient introduction of the eluent into the FID. The potential of the method is demonstrated by the μLC-FID determination of lower alcohols and bis(2-hydroxyethylthio)alkanes on porous and non-porous stationary phases, respectively. Flow injection analysis (FIA)-FID experiments with highly polar, thermolabile, semi-volatile and non-volatile compounds like amino acids, organic acids, alkylphosphonic acids, and carbohydrates showed the developed configuration to be a promising approach for the detection of a wide range of analytes. Compared with a nebulization interface, the eluent-jet interface showed 4-10 times higher peaks for citric acid. Detection limits by FIA for all compounds were in the range of 0.2-5 ng injected. With ribose as test compound, plots of peak height vs. amount injected showed good linearity (r2 〉 0.999) in the range of 75-12,000 μg/mL. The repeatability showed relative standard deviations of less than 5%.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 1H and 13C n.m.r. studies of a series of twelve 1,2-dithiole-3-ylidene ketones and aldehydes have shown that the geometry of the carbon backbone is the same as found in 1,6,6aλ4-trithiapentalenes. No evidence has been found which favours a bicyclic structure for the system. A linear correlation of observed 13C chemical shifts with calculated charge densities is found to be valid. The observations are in agreement with a structure which is a hybrid between a true ketonic structure and a true mesoionic structure.By using the difference in the 13C chemical shifts of ortho and meta carbon atoms in substituent phenyl groups it is possible to qualify the degree of coplanarity of the phenyl groups with the backbone of the molecule.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Reactivity differences between odd ([M]+) and even electron ions (α-cleavage product) were studied by comparing water elimination mechanisms in 6-undecanol. The compounds specifically labelled with deuterium in positions 6, 5 + 7, 4 + 8 and 3 + 9 were made, and a detailed investigation of tghe metastable ion transitions carried out. A highly specific 1,4 elimination of water without preceding intramolecular hydrogen exchange occurs from [M]+, but equal amounts of 1,3 and 1,4 elimination of water preceded by specific hydrogen exchange between -OH and the hydrocarbon chain occurs from the α-cleavage ion [M - C5H11]+. To make such distinctions a thorough examination of metastable ions is essential.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 11 (1976), S. 458-467 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The loss of water from the molecular ion of 2-adamantanol was investigated using specifically labelled deuterium derivatives, and, in particular that stereospecifically labelled in position 4. Water is lost predominantly in a stereospecific 1, 3 fashion by two clearly distinguishable mechanisms. Determination of metastable ion characteristics proved to be essential for drawing this distinction.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...