ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (16)
  • Animals  (15)
  • 2000-2004  (7)
  • 1990-1994  (10)
  • 1985-1989  (3)
  • 1975-1979  (7)
  • 1970-1974  (4)
  • 1
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 178 (1977), S. 465-474 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A systematic study of the effect of potassium hydroxide on the autoxidation of poly(propylene oxide)s with number average molecular weights, M̄n, in the range 400-3000 has been made in the range of temperature 110-140°C. For all the polymers a considerable increase in the induction time was produced by KOH in solution in the polymer, the increase being most marked for the polymer of lowest molecular weight. For the polymers of molecular weight 1000 and lower, the rate of the subsequent autoxidation was considerably reduced by the KOH, the effect being greatest for the polymer of molecular weight 400. For polymers of molecular weight 2000 and above no change in rate was observed. The effectiveness of KOH as an antioxidant is shown to depend on the concentration of terminal hydroxyl groups and is explained by the non-radical decomposition of RO-2 ions.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 21 (1977), S. 3099-3109 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A series of six Hytrel/PVC blends were prepared by solution blending Hytrel in methylene chloride and PVC in tetrahydrofuran. The samples were subsequently prepared in sheet form by hot pressing at 170°C. Physical and mechanical properties of the homopolymers and the blends were investigated. The copolyester homopolymer is a partly crystalline elastomeric material. The level of crystallinity was measured by x-ray diffraction and the sensitivity of this level to heat treatments and quenching determined by DSC. A Morgan pulse propagation meter was used to measure sonic velocity and, indirectly, acoustic impedance of the blends. Dynamic mechanical studies indicated that blends containing 25%-50% by weight of Hytrel were completely compatible in the sense that a single glass transition was observed; but as the Hytrel level was increased to 60% and 65%, a shoulder became apparent on the low-temperature side of the glass transition peak. At 80% Hytrel, two peaks were observed, indicating incompatibility. The glass transition temperatures of these blends were found to decrease linearly with added Hytrel.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0887-624X
    Keywords: oligocyclosiloxanes ; hydrosilation ; heptamethylcyclotetrasiloxane ; siloxane redistribution ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The preparation of oligocyclosiloxanes via hydrosilation reactions has been investigated. Hydrosilation reactions employing heptamethylcyclotetrasiloxane and vinyl-containing silanes and siloxanes yielded a variety of oligocyclosiloxanes with various numbers of cyclosiloxane rings connected through tri-, tetra-, penta-, hexa-, hepta-, or octafunctional junctions. The oligocyclosiloxanes were characterized by gas chromatography, IR spectroscopy, 29Si-, 1H-, and 13C-NMR spectroscopy, elemental analysis, and vapor phase osmometry. The polycyclics were redistributed with hexamethyldisiloxane and the resulting fragments analyzed by gas chromatography. All results were consistent with the formation of isomeric oligocyclosiloxanes due to a lack of absolute regioselectivity of the hydrosilation reaction. © 1993 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 53 (1994), S. 485-496 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new route (“direct forming”) was developed for forming dense PBI shapes from PBI powder. The new process affords the possibility of automated PBI powder shaping (“cold compaction”) and densification in batches of multiple parts by a “powder-assisted hot isostatic pressing” process. Direct forming is a more productive alternative to hot compression molding. Two developments enable PBI direct forming: (1) the discovery that PBI powders that are porous and plasticized with moisture can be shaped by compaction at ambient temperatures (cold-compacted), and (2) a finding that cold-compacted shapes can be densified in large batches by a powder-assisted hot isostatic pressing. The porous PBI powder is formed from PBI in solution by a spray-precipitation process. When plasticized with moisture, this powder is cold-compactible to PBI shapes with densities up to 94% of that of ultimate density of PBI. These shapes, which have sufficient strength to be handled, are then further consolidated via powder-assisted hot isostatic pressing to shapes with excellent thermal and mechanical properties and densities of about 99% of the ultimate. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The need for alternatives to autogenous bone grafts is widely recognized. This study compared the torsional strength of canine femora 1 year after grafting with one of three forms of a collagen/hydroxyapatite/tricalcium phosphate bone grafting material (COLLAGRAFT15), autogenous bone, or no graft. The groups were compared to each other and to the unoperated contralateral femora. Results of torsional testing were evaluated for torsional strength, torsional displacement, total energy to fracture and White fracture mode. Data analysis showed lower torsional strength of the operated vs. unoperated femora with the exception of morsellized COLLAGRAFT15 material, which had higher strength. However, the only difference in the operated groups was that the morsellized COLLAGRAFT15 had greater strength than several groups including the autogenous bone group. There was no difference found in angular displacement between any of the groups. However, there was a difference in the energy to fracture in both strip forms of the COLLAGRAFT15. The final conclusion is that in this model, grafting with COLLAGRAFT15 provided torsional properties at one year postoperatively at least equivalent to autogenous bone. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 19 (1975), S. 435-450 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Three preparative-scale gel permeation chromatography columns were constructed and filled with Corning porous-glass packing materials. Each column was packed with a different pore-size materials, CPG 10-2000, CPG 10-350, CPG 10-120, all of which had been treated with hexamethyldisilazane. An additional preparative-scale column packed with Styragel, nominal porosity 5 × 104 Å, was added to complete the column bank. Polystyrene standards were used to investigate the effects of molecular weight and sample concentration upon elution volume. A commerical polystyrene sample was fractionated using this system to study the effects of sample concentration and flow rate on fractionation efficiency. These fractions were analyzed by high-resolution analyticalscale gel permeation chromatography. Where possible, the results have been compared with similar studies that used Porasil (Spherosil) and Styragel columns.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 155-162 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Clinical studies will permit only small sections of tendon sheaths to be removed for biopsy at restricted levels as the sheaths were to be used for tendon grafting. In active gliding programs, biopsy has been limited to small sheath sections in immediate relation to the distal or proximal anastomosis where gliding motion may be induced or minimal. In the passive gliding programs, biopsy has been limited to the most proximal segments where considerable folding of the sheath occurs or cul-de-sac buckling of the implant may produce irritation.As these were the only practical clinical sources of sheath sections for biopsy and study, the authors felt that a comparison study of sheath development in animals would broaden our understanding in humans. With this objective in mind, three canine laboratory studies were carried out where, for pure purposes of investigation, entire sheath sections were removed at designated time intervals for study.The flexible implants were well accepted, affording the opportunity to observe development of early sheaths in a controlled connective tissue environment, free from the stress of joint motion.The semi-rigid implants showed equal acceptance in side-by-side tissue level of the same dog as the flexible implant. This influenced changes in artificial tendon development from extrusion to the more exacting mold fabrication. It seemed evident that the degree of increase in stiffness of the new artificial tendons to gain a superior surface for gliding and increased strength would not change tissue acceptance providing flexibility was maintained.The cellular response in this study did not seem to represent a foreign body phenomena but an orderly acceptance of the soft tissue environment to the smooth surface of the inert implant.It is concluded that this study confirmed in animals the clinical findings of Mayer, Bunnell, Milgram, and Carroll.The consistent orderly development of the new sheaths formed in response to the static implants is impressive. The authors believe the appearance of these histologic sections are likely correlations with the development of new sheaths around the Hunter Tendon Prosthesis during the three-four week postoperative period when the hand is resting in a functional dressing.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 13 (1979), S. 407-422 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In the present study the conditions leading to tight binding of human serum albumin to the Amberlite XAD-7 resin without the use of chemical coupling agents have been defined. Optimal binding (10.97 mm/kg dry XAD-7) was achieved at pH 5.0 and adsorption conformed to a Langmuir isotherm. Theoretical analysis of the data suggest adsorption of a monolayer of albumin which is suported by the absence of visual surface coating on scanning electron micrographs. Binding of human serum albumin was reduced when two chemical coupling agents, glutaraldehyde and carbodiimide were included in the human serum albumin solution, the elution of adsorbed HSA from the resins under severe flow conditions was reduced, and the amount eluted was minimal in all instances.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 137-144 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In sheep, chronic arterial cannulation with Silastic has led to thrombus formation and to intimal fibroplasia of a type not previously reported. Concurrent infection resulted in septic embolization to the brains and eyes on the same side as the cannulated vessels. The histopathology is described in detail.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 6 (1972), S. 33-48 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Additional Material: 19 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...