ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (69)
  • Analytical Chemistry and Spectroscopy  (62)
  • AERODYNAMICS  (41)
  • Lunar and Planetary Science and Exploration
  • 2005-2009  (13)
  • 1980-1984  (109)
  • 1970-1974  (63)
Collection
Keywords
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 13 (1980), S. 396-402 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rotational barriers and 15N chemical shifts have been measured in a number of ureas and thioureas. As anticipated on the basis of the 15N shifts, several previously unobserved rotational barriers could be detected by using lanthanide reagents or a high field spectrometer. Nearly constant effects on both the rotational activation energy and the 15N shift are produced on going from ureas to the corresponding thioureas, and correlations are found between the ΔG
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 184 (1983), S. 105-111 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The influence of the degree of polymerization of oligomers (1 ≤ l ≤ 50) on the reactivity of the OH endgroups is exemplified by the reaction of oligoterephthalates of phenolphthalein with benzoyl chloride under ϑ-conditions. It is found that with increasing chain length l the hydroxyl group activity increases according to an S-form law. It is suggested that the ester groups of the macromolecule influence the activity of the OH endgroups due to solvation effects. This suggestion is confirmed theoretically and experimentally.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Polytetrafluoroethylene surfaces have been treated to reduce thrombogenicity in order to make them suitable for use in prosthetic devices that come in contact with blood. This was done by first etching the surface with potassium in liquid ammonia to produce double bonds and then using these double bonds as sites for grafting on polyacids or as sites for chemical reactions. Tubes so treated were tested for thrombo-genetic activity by implantation in the thoracic aorta or inferior vena cava of dogs. These tests showed that the thrombogenicity of a polytetrafluoroethylene surface can be reduced by attaching negatively charged groups provided the surface concentration of these groups is not too high (order of 1-2 × 10-6 equivalent per cm2 geometric area) and provided the distribution of these groups is uniform. Sulfonic acid groups obtained by chlorosulfonation and carboxyl groups attached by grafting tert-butyl crotonate and hydrolyzing to crotonic acid were effective. Long chains of poly(acrylic acid), poly-(ethylenesulfonic acid), and poly(vinyl alcohol) sulfate were less effective.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 25 (1980), S. 1703-1713 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The tensile behavior of blends of linear polyethylene (PE) and isotactic polypropylene (PP) was examined in relation to their morphology. Yield stress increases monotonically with increasing PP content, while true ultimate strength is much lower in all blends than in the pure polymers as a result of early fracture. The blends fail at low elongation because of their two-phase structure, consisting of interpenetrating networks or of islands of PE in a PP matrix, as shown by scanning electron microscopy of fracture surfaces and transmission electron microscopy of thin films. While spherulites in PP are very large (∼100 μm in diameter), addition of 10% or more of PE drastically reduces their average size. This, together with the profusion of intercrystalline links introduced by PE, may be associated with maximization of tensile modulus in blends containing ∼80% PP. Introduction of special nucleating agents to PP reduces average spherulite size and is accompanied by slight improvements in modulus. Thin films of blends strained in the electron microscope neck and fibrillate in their PE regions, but fracture cleanly with little fibrillation in areas of PP.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 312-318 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography ; Capillary column ; Column diameter ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillary columns with internal diameters from 100 to 25 μm were coated with SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. At ten times the optimum mobile phase velocity and for a capacity factor, k of 3, efficiencies of 2300 to 5600 plates m-1 were obtained for column diameters of 100 to 25 μm, respectively.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 423-428 
    ISSN: 0935-6304
    Keywords: Capillary column ; Supercritical fluid chromatography ; Stationary phase film thickness ; Efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused-silica capillary columns with internal diameters of 50 μm were coated with 0.25 to 1.0 μm films of SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. There was no significant difference in hmin or ūopt for film thicknesses from 0.25 to 1.0 μm over k = 1 to 5. At a film thickness of 1.0 μm, calculations indicate that approximately 10% resolution loss would be expected for solutes with k = 1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 413-416 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Stationary phase stability ; Stationary phase viscosity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: With recent advances in column technology it is now possible to prepare highly efficient, very inert, and thermally stable capillary columns coated with nonpolar polysiloxane stationary phases. Unfortunately, the same degree of success has not been achieved for some of the more polar polysiloxane phases. A parameter that has been studied little in the past in relation to stationary phase film stability is the viscosity of the stationary phase. In this paper the efficiency and stability of coated columns are correlated to the viscosity of the phase. Due to their structure, the viscosity of the phenyl-containing polysiloxanes change rapidly with temperature and hence, thin-film coatings are not stable at elevated temperatures. By using high viscosity phenyl-containing methylphenylpolysiloxanes which were recently synthesized, efficient and stable columns have been prepared.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 89-92 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Stationary phase ; Polysiloxane ; Autocrosslinkable ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methyl-2-phenylethylpolysiloxane polymers have been synthesized for comparison with methylphenylpolysiloxane stationary phases for gas chromatography. The 50% 2-phenylethyl polysiloxane was found to be autocrosslinkable at 260°C without addition of free redical initiator. Although the selectivity of this phase appears to be similar to the 50% phenyl polysiloxane, its thermal stability is not as high.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...