ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • OPTICS  (18)
  • Analytical Chemistry and Spectroscopy  (5)
  • 1H and 13C NMR
  • 2005-2009
  • 1990-1994  (23)
  • 1965-1969
  • 1930-1934
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 28 (1993), S. 340-343 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Ion-ion coincidence measurements following K-shell absorption in the carbon dioxide molecule were performed by applying time-of-flight mass spectrometry in conjunction with monochromatic synchrotron radiation and electron impact. Identification of particularly sensitive electronic transitions and the consecutive molecular fragmentation in real time was performed. Analysis of coincidence recordings from decomposition of carbon dioxide reveals one distinct pathway in which three cations are formed following excitation of oxygen Is electrons.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 555-560 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The application of fast-atom bombardment mass Spectrometry and collisiorutlly induced dissociation with mass-analysed ion kinetic energy (CID/MIKE) Spectrometry of representative inositol mono-, bis- and trisphos-phates is described. Based on their CID/MIKE spectra, inositol polyphosphates containing vicinal phosphate groups could be distinguished from isomers in which adjacent phosphate groups were absent. The potential value of this procedure in studies of the biochemistry of intracellular second messengers is discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 217-221 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Nanogram quantities of glucuronic acid conjugates of GR117289 in rat and dog bile have been analysed by semi-microbore high-performance liquid chromatography (HPLC)/ionspray mass spectrometry with on-line UV diode array detection. The determination of drug metabolites in bile has often proved problematical due to the large number of endogenous components in this biological matrix, in particular the bile acids. Semi-microbore HPLC is useful for concentrating small quantities of material and, in combination with an on-line diode array detector, for distinguishing between drug related and endogenous components. A novel angiotensin II receptor antagonist, GR117289, had proved difficult to analyse by thermospray mass spectrometry because of its thermal lability. The use of the less thermally dependent technique of ionspray mass spectrometry allowed the characterization of nanogram quantities of glucuronic acid metabolites of GR117289 in bile.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0749-1581
    Keywords: Zearalenone ; Zearalanone ; 1H and 13C NMR ; Molecular modelling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The complete 1H and 13C NMR spectra of the mycotoxin zearalenone are described. An analysis of all the vicinal proton-proton coupling constants, together with molecular modelling results, leads to a three-dimensional structure very similar to those observed x-ray crystallographically for related systems. Analogous data on zearalanone reveal that whereas the overall molecular geometry is similar to that of zearalenone, the alkyl terminus of the 12-membered bridging moiety is now oriented almost orthogonally to the aromatic ring plane.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0749-1581
    Keywords: 1H NMR ; 19F Corticosteroids ; 1H-19F long-range coupling ; Heteronuclear COSY ; 1H-19F 2D correlation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The analysis of the 1H and 19F NMR spectra of the corticosteroid fluocinonide and five related steroids is reported. The 500 MHz 1H NMR spectra revealed several previously undetected long-range 1H-19F coupling constants. These couplings were assigned by the application of the heteronuclear equivalent of the COSY pulse sequence. The fluorine substituent effects and long-range heteronuclear couplings were examined in relation to structures derived from molecular mechanics (MMX) calculations.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-24
    Description: X-ray testing of the AXAF outer mirror pairs, in the VETA-1 configuration, reveals a point spread function (PSF) with unexpectedly large wings at low energies. Although the angular dependence in the wings of the PSF is close to that expected for diffractive scattering from surface roughness, the energy dependence differs substantially. Analyses of the observed X-ray PSF, images near ring focus, and single-quadrant images at conjugate focus suggest that the excess scattering observed at low X-ray energies results from diffractive scattering by relatively small grains (as small as a few tenths micrometer in radius). We develop a simple model for the contribution of scattering by particulates to the PSF. Merging this model with that for scattering by surface roughness, we fit the combined model to the observed energy-dependent PSF, in order to estimate parameters and associated uncertainties characterizing the grain-size distribution and the surface-roughness power spectral density. In particular, we find that the fractional coverage of the mirrors by particulates is approximately 1 x 10 exp -4 (for grain radii between 0.1 and 10 microns), and that the rms surface-roughness is approximately 0.7 nm (for spatial frequencies between 1/mm and 1000/mm).
    Keywords: OPTICS
    Type: In: Multilayer and grazing incidence X-ray(EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-39601 15-74); p. 171-182.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-24
    Description: Initial core scan data of the VETA-1 X-ray mirror proved disappointing, showing considerable unpredicted image structure and poor measured FWHM. 2-D core scans were performed, providing important insight into the nature of the distortion. Image deconvolutions using a raytraced model PSF was performed successfully to reinforce our conclusion regarding the origin of the astigmatism. A mechanical correction was made to the optical structure, and the minor was tested successfully (FWHM 0.22 arcsec) as a result.
    Keywords: OPTICS
    Type: In: Multilayer and grazing incidence X-ray(EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992 (A93-39601 15-74); p. 136-151.
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2013-08-31
    Description: The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2013-08-31
    Description: We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are one dimensional scans of the core of the point response function (PRF) (full width half maximum (FWHM) scans), the encircled energy as a function of radius, and one dimensional scans of the wings of the PRF. We discuss briefly our ray trace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1 mm(exp -1). Constraints on the average amplitude of circumferential slope errors are derived as well.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2013-08-31
    Description: The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 8 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...