ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Munksgaard International Publishers  (2)
  • 2015-2019
  • 1995-1999  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 7 (1997), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Concentrations of volatile organic compounds (VOCs) measured indoors may exceed their odor thresholds, but are usually far below TLV estimates. Even applying additivity to eye and airway irritation effects, it is difficult to rationalize increased sick building syndrome (SBS) symptoms by exposure to generally chemically inert VOCs in the indoor environment.Several studies suggest that chemical reactions in indoor air are linked with SBS symptoms and the examination of these reactions may be necessary in order to understand the role of VOCs as causative agents of SBS symptoms.The usual evaluation of odor annoyance of VOCs based on odor thresholds should be modified, taking into account the large variation of individual human odor thresholds for single substances, and specific additivity phenomena even at subthreshold levels of VOCs.The conclusion of this review is that chemical reactions between oxidizable VOCs and oxidants, such as ozone and possibly nitrogen oxides, can form irritants which may be responsible for the reported symptoms. Compounds adsorbed to particles may also contribute to SBS symptoms. The individual effects of indoor pollutants may act in concert with temperature and relative humidity. New analytical methods are required to measure the oxidative and reactive species or specific markers thereof in indoor air.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: The volatile organic compounds (VOCs) emitted from 12 linoleum samples were measured by use of the “Field and Laboratory Emission Cell” (FLEC) with sampling on Tenax TA followed by thermal desorbtion and GC/FID or GC/MS analysis. Major VOCs were alkanals, alkenals and fatty acids. The emissions were measured after 24 h in FLEC and again after one month's storage in a well ventilated room. The emission profiles of hexanal, nonanal and propanoic acid were modeled for four linoleum samples using a new exponential diffusion model. The time required to reach 50% of the odor threshold concentrations in a standard room was from 113 to 2296 hours. The applicability of the diffusion model for modeling long-term emission needs to be further evaluated considering possible continuous oxidative emission.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...