ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2019-12-01
    Description: Increasing demands for small-scale radiocarbon (14C) analyses required the installation of a “SO-110 B” type ion source (HVE Europa B.V.) at our 6 MV Tandetron AMS (HVE) dedicated for the direct injection of CO2 using either the gas injection system (GIS) from Ionplus AG or a EuroVector EA 3000 elemental analyzer (EA). We tested both systems with multiple series of 14C-free and modern standards (2.5–50 µg C) combusted in quartz ampoules or EA containers and were able to quantify exogenous C introduced. In EA-GIS-AMS analysis exogenous C is mainly derived from the EA sample containers. Blank values for 50 µg C combusted in solvent-cleaned tin (Sn) vessels were 0.0127 ± 0.0012 F14C (boats) and 0.0090 ± 0.0010 F14C (capsules), while they were much higher for thermally cleaned silver (Ag) capsules. The processing of gas samples for GIS-AMS yields similar blank values corresponding to 0.30 ± 0.08 µg exogenous C with 0.93 ± 0.23 F14C consisting of 0.28 µg C modern and 0.02 µg C fossil C. The combustion of larger amounts of blank material (1 mg C) in a single quartz tube split into aliquots gives lower blanks (0.0064 ± 0.0008 F14C; 50 µg C). Thus, 14C analysis of small, gaseous samples is now possible at CologneAMS.
    Print ISSN: 0033-8222
    Electronic ISSN: 1945-5755
    Topics: Archaeology , Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-04-26
    Description: This work summarizes the methodical capabilities, improvements, and new developments in the radiocarbon laboratory of the accelerator mass spectrometry (AMS) facility at the University of Cologne, Germany, which was established in 2010. During the past years, the laboratory has specialized in the analysis of small and gaseous samples. We thus, recently installed a second ion source dedicated for radiocarbon (14C) analysis of CO2 samples at our 6 MV Tandetron AMS from High Voltage Engineering Europe B.V. that is coupled with the gas injection system from Ionplus and an EuroVector EA 3000 elemental analyzer. This work summarizes all pretreatment methods and analytical facilities established in our laboratory during the last years including 14C analysis of individual organic compounds and of CO2 trapped on molecular sieves. We also report different blank values including our long-term blank since 2011, which is for normal-sized, solid samples (650–1000 µg C) 0.0012 ± 0.0004 F14C (54,305 ± 2581 yr BP, n = 484). The precision obtained for modern samples measured as graphite is 0.5% and for gaseous samples injected with the GIS ≤2%.
    Print ISSN: 0033-8222
    Electronic ISSN: 1945-5755
    Topics: Archaeology , Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...