ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (18)
  • 2015-2019
  • 2000-2004  (4)
  • 1980-1984  (3)
  • 1970-1974  (11)
  • 1
    Publication Date: 2011-08-24
    Description: Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on osteoblastic function, we seeded MC3T3-E1 cells into collagen gels and applied the following loading protocols for 3 min per day for either 3 or 7 days: (1) sinusoidal strain at 3 Hz, with 0-3000 microstrain peak-to-peak followed by 0.33 s resting time, (2) "broad frequency vibration" of low amplitude strain (standard deviation of 300 microstrain) including frequency components from 0 to 50 Hz, and (3) sinusoidal strain combined with broad frequency vibration (S + V). The cells were harvested on day 4 or 8. We found that the S + V stimulation significantly repressed cell proliferation by day 8. Osteocalcin mRNA was up-regulated 2.6-fold after 7 days of S + V stimulation, and MMP-9 mRNA was elevated 1.3-fold after 3 days of vibration alone. Sinusoidal stimulation alone did not affect the cell responses. No differences due to loading were observed in alkaline phosphatase activity and in mRNA levels of type I collagen, osteopontin, connexin 43, MMPs-1A, -3, -13. These results suggest that osteoblasts are more sensitive to low amplitude, broad frequency strain, and this kind of strain could sensitize osteoblasts to high amplitude, low frequency strain. This suggestion implies a potential contribution of stochastic resonance to the mechanical sensitivity of osteoblasts. Copyright 2002 Elsevier Science Ltd.
    Keywords: Aerospace Medicine
    Type: Journal of biomechanics (ISSN 0021-9290); Volume 36; 1; 73-80
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2013-08-31
    Description: NASA's Mars Surveyor Program (MSP) began in 1994 with plans to send spacecraft to Mars every 26 months. Mars Global Surveyor (MGS), a global mapping mission, was launched in 1996 and is currently orbiting Mars. Mars Surveyor '98 consisted of Mars Climate Orbiter (MCO) and Mars Polar Lander (MPL). Lockheed Martin Astronautics (LMA) was the prime contractor for Mars Surveyor '98. The Jet Propulsion Laboratory (JPL), California Institute of Technology, manages the Mars Surveyor Program for NASA's Office of Space Science. MPL was developed under very tight funding constraints. The combined development cost of MPL and MCO, including the cost of the two launch vehicles, was approximately the same as the development cost of the Mars Pathfinder mission, including the cost of its single launch vehicle. The MPL project accepted the challenge to develop effective implementation methodologies consistent with programmatic requirements.
    Keywords: Lunar and Planetary Science and Exploration
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2018-06-11
    Description: The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI). The MI is a fixed-focus camera mounted on an extendable arm, the Instrument Deployment Device (IDD). The MI acquires images at a spatial resolution of 30 microns/pixel over a broad spectral range (400 - 700 nm). The MI uses the same electronics design as the other MER cameras but its optics yield a field of view of 31 x 31 mm across a 1024 x 1024 pixel CCD image. The MI acquires images using only solar or skylight illumination of the target surface. A contact sensor is used to place the MI slightly closer to the target surface than its best focus distance (about 69 mm), allowing concave surfaces to be imaged in good focus. Coarse focusing (approx. 2 mm precision) is achieved by moving the IDD away from a rock target after contact is sensed. The MI optics are protected from the Martian environment by a retractable dust cover. This cover includes a Kapton window that is tinted orange to restrict the spectral bandpass to 500 - 700 nm, allowing crude color information to be obtained by acquiring images with the cover open and closed. The MI science objectives, instrument design and calibration, operation, and data processing were described by Herkenhoff et al. Initial results of the MI experiment on both MER rovers ('Spirit' and 'Opportunity') are described below.
    Keywords: Lunar and Planetary Science and Exploration
    Type: Lunar and Planetary Science XXXV: Mars Missions; LPI-Contrib-1197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-06-28
    Description: Operational leakage rates of various working fluids predicted from test data. Method converts leakage through fixed area flow passage from one set of fluid conditions to another. Correction factor improves correlation of measured engine static seal leak rate under test conditions with rate under operating conditions. Potential applications include extrapolating from test conditions to operating condition.
    Keywords: MECHANICS
    Type: MFS-19674 , NASA Tech Briefs (ISSN 0145-319X); 7; P. 425
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-27
    Description: The double-pulse, double-exposure holography technique was applied to visualize the flow field within a transonic compressor rotor with a tip speed of 1800 ft/sec. The principal objective was to visualize the shock waves created in the flow field which was supersonic relative to the rotating blade row. The upstream rotor blade bow shocks and, at high speed, the outermost portion of the leading edge passage shock were successfully observed in the holograms. Techniques were devised for locating these shocks in three dimensions, and the results were compared with theoretical predictions. Density changes between the two pulses due to motion of the shocks were large and, therefore, it was not possible to resolve the fringe systems in detail for the 100% speed conditions. However, gross features of the shocks were easily observed, and the upstream shocks were well displayed. In all cases the shock angles were somewhat larger than predicted by theory, and a distinct increase in angle near the outer wall was observed, which may be attributed to endwall boundary layer effects. The location and orientation of the observed leading edge passage shocks were in good agreement with static pressure contours obtained from measurements in the outer casing over the rotor tip.
    Keywords: FLUID MECHANICS
    Type: NASA-CR-121112 , PWA-4712
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-27
    Description: Air quality data for Cleveland, Ohio, for the period of 1967 to 1971 were collated and subjected to statistical analysis. The total suspended particulate component is lognormally distributed; while sulfur dioxide and nitrogen dioxide are reasonably approximated by lognormal distributions. Only sulfur dioxide, in some residential neighborhoods, meets Ohio air quality standards. Air quality has definitely improved in the industrial valley, while in the rest of the city, only sulfur dioxide has shown consistent improvement. A pollution index is introduced which displays directly the degree to which the environmental air conforms to mandated standards.
    Keywords: METEOROLOGY
    Type: NASA-TN-D-6935 , E-7006
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-27
    Description: Air-quality data for metropolitan Cleveland, Ohio, from 1967 through 1972 were collated and statistically analyzed. Total suspended particulates (TSP) departed from lognormal distribution in 1972. Nitrogen dioxide and sulfur dioxide, departed significantly from lognormal distributions in 1972. In Cleveland the Ohio standards were not met. However, the data indicate a general improvement in air quality. Unusually high precipitation (43% above the average in 1972) may be responsible in lowering these values from the 1971 levels. The mean values of TSP, NO2, and SO2 are 104, 191, and 83 microgram/cu m respectively.
    Keywords: GEOPHYSICS
    Type: NASA-TM-X-3113 , E-7850
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-06-28
    Description: Thin wire welded to bottom of hole down center of bolt permits measurement of tension in bolt. Bolt lengthens under strain, but wire is not loaded, so gap between wire and eddy-current gap transducer mounted on bolt head indicates bolt loading. Eddy-current transducer could measure gap within 0.05 mm. Method does not require separate "standard" for each bolt type, and is not sensitive to dirt or oil in bolt hole, unlike ultrasonic probes.
    Keywords: MECHANICS
    Type: MFS-19486 , NASA Tech Briefs (ISSN 0145-319X); 5; 1; P. 68
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: The NASA Lewis Research Center is assisting the City of Cleveland, Ohio, in its effort to monitor its air pollution. This report describes the Cleveland program of the past 4 years and the supportive Lewis program currently being developed. The data accumulated by Cleveland over the past 4 years are presented together with some preliminary statistical analyses indicating in a semiquantitive manner the degree of air pollution existing within the boundaries of Cleveland.
    Keywords: METEOROLOGY
    Type: NASA-TM-X-2496 , E-6635
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: Filter cassette eliminates or substantially reduces contamination of filter media by extraneous material and facilitates handling.
    Keywords: PHYSICAL SCIENCES
    Type: LEW-11469
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...