ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 41.20. — q  (1)
  • Column technology  (1)
  • Springer  (2)
  • Oxford University Press
  • 2015-2019
  • 2005-2009
  • 1995-1999  (2)
Collection
Publisher
  • Springer  (2)
  • Oxford University Press
Years
  • 2015-2019
  • 2005-2009
  • 1995-1999  (2)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 62 (1996), S. 263-268 
    ISSN: 1432-0630
    Keywords: 78.20. — e ; 41.20. — q
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The PhotoAcoustic (PA) method has been used to study the optical resonance absorptions on corrugated surfaces. The resonance absorptions due to the excitations of surface plasmons and guide-waves of corrugated surfaces have been measured experimentally, and the effects of the groove depth and period of the corrugated surface on the absorption curve have been observed. Moreover, the differential method based on the rigorous use of electromagnetic theory is used to calculate the parameters of the grooves and the optical absorptivities of the samples. The theoretical results on the resonance absorption peaks are in good agreement with those of the PA experiments. Then, the parameters of the grooves can be estimated by the PA investigations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Capillary electrophoresis ; Column technology ; Deactivation ; Polyethyleneoxides ; Ribonucleotides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary In this study, a variety of fused silica capillaries with different combinations and sequences of treatments with HMDS and polyethylene oxide were prepared in order to develop an optimized column modification method for analysis of ribonucleotides. The 12 most common ribonucleotides (UTP, CTP, ATP, GTP, UDP, CDP, ADP, GDP, UMP, CMP, AMP, and GMP) in human cells were used as test solutes. Column performance measurements, including electroosmotic flow (EOF), solute migration speed and retention, column efficiency, peak shape, and resolution were investigated. By analyzing solute migration speed and retention of various hydrophilic/hydrophobic solutes, the column wall effects (EOF and adsorption) can be distinguished. This analysis method can give guidance in optimizing polymer coating properties (hydrophilicity/hydrophobicity) for CE columns. By studying the performance of these columns after various surface treatments, we were able to improve the separation of ribonucleotides from real samples to within 16 minutes with high efficiency and stability (over 300 analyses) using columns first deactivated with hexamethyldisilazane, and then coated with polyethylene oxide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...