ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (1)
  • detection capability  (1)
  • 2020-2024  (1)
  • 1930-1934
Collection
  • Other Sources  (1)
Source
Language
Years
  • 2020-2024  (1)
  • 1930-1934
Year
  • 1
    Publication Date: 2023-06-20
    Description: All nuclear explosions are banned by the Comprehensive Nuclear-Test-Ban Treaty. In the context of the treaty a verification regime was put into place to detect, locate, and characterize nuclear explosions at any time, by anyone and everywhere on the Earth. The International Monitoring System, which plays a key role in the verification regime, was set up by the Preparatory Commission of the Comprehensive Nuclear-Test-Ban Treaty Organization. Out of the several different monitoring techniques applied in the International Monitoring System the seismic waveform approach is the most effective and reliable technology for monitoring nuclear explosions underground. This study introduces a deterministic method of threshold monitoring that allows to asses a lower body wave magnitude limit of a potential seismic event in a certain geographical region, that can be detected by those seismic stations being part of the International Monitoring System network. The method is based on measurements of ambient seismic noise levels at the individual seismic stations along with global distance corrections terms for the body wave magnitude. The results suggest that an average global detection capability of approximately body wave magnitude 4.0 can be achieved using only stations from the primary seismic network of the International Monitoring System. The incorporation of seismic stations from the auxiliary seismic network leads to a slight improvement of the detection capability, while the use and analysis of wave arrivals from distances greater than 120∘ results in a significant improvement of the detection capability. Temporal variations in terms of hourly and monthly changes of the global detection capability can not be observed. Overall, comparisons between detection capability and manually retrieved body wave magnitudes from the Reviewed Event Bulletin suggest, that our method yields a more conservative estimation of the detection capability and that in reality detection thresholds might be even lower than estimated.
    Description: Bundesanstalt für Geowissenschaften und Rohstoffe (BGR) (4230)
    Keywords: ddc:551.22 ; International monitoring system ; seismology ; detection capability ; ambient seismic noise ; body wave magnitude correction curves
    Language: English
    Type: doc-type:article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...