ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Bone  (49)
  • NDE  (21)
  • Springer  (70)
  • PANGAEA
  • 2020-2023
  • 2000-2004  (1)
  • 1980-1984  (37)
  • 1970-1974  (32)
Collection
Publisher
  • Springer  (70)
  • PANGAEA
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 12 (1973), S. 73-90 
    ISSN: 1432-0827
    Keywords: Bone ; Mineral ; Properties ; Deproteination ; Hydrazine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Une méthode, utilisant 95% d'hydrazine, permet de déprotéiniser et de déshydrater légèrement l'os dans des conditions presqu'anhydres, avec une élévation de température modérée. Cette méthode ne provoque que des modifications chimiques mineures, sans altération des propriétés structurales de la phase minérale. Les résultats physico-chimiques démontrent que bien que les cristaux d'os de rat sont viosins de cristaux synthétiques témoins constitués dans des milieux, riches en carbonate plutôt qu'en hydroxyde, l'apatite osseux de rat ne parait pas analogue à des modèles cristallins connus ou imaginés. Des déterminations de bande infra-rouge CO 3 2− , réalisées à partir de spectre d'os total, semblent faussées par la présence de bandes d'absorption protéique. L'absorption d'HPO 4 2− est étudiée à l'aide de spectres infra-rouges de minéral osseux de jeunes rats. Des comparaisons détaillées en diffraction par raysons X d'os déprotéinisé de rats, avant et après hydrolyse, démontrent nettement la présence de phosphate de calcium amorphe. La microscopie électronique indique que de petits cristaux d'apatite dans l'os de rat sont susceptibles de contribuer au pool minéral amorphe en diffraction en rayons X. La microscopie électronique montre des plages de minéral osseux de rat où des cristaux d'apatite en forme de plaque, présentent une maille cristalline avec axe C malgré l'élimination de leur matrice fibreuse.
    Abstract: Zusammenfassung Es wird eine Methode beschrieben, wobei durch Anwendung von 95% Hydrazin ohne Wasserzugabe und mit nur geringem Erhitzen dem Knochen das gesamte Protein und ein kleiner Teil des Wassers entzogen wird. Diese Methode führte nur zu geringen chemischen Veränderungen und veränderte die strukturellen Eigenschaften der Mineralphase in keiner Weise. Physikochemische Daten wurden erbracht, welche zeigen, daß — obwohl die Kristalle von Rattenknochen den synthetischen Kontrollen (in Karbonat- und nicht hydroxydreichen Medien hergestellt) eher gleichen — Apatit aus Rattenknochen nicht auf sinnvolle Weise mittels bekannten oder postulierten Kristallmodellen interpretiert werden kann. CO 3 2− -Infrarotbandenzuteilungen, welche von Spektren aus dem Gesamtknochen gemacht wurden, geben wegen der Anwesenheit von Proteinabsorptionsbändern falsche Resultate. Die Absorption von HPO 4 2− wurde in den Infrarotspektren von Knochenmineral aus jungen Ratten beobachtet. Ein Vergleich der detaillierten Röntgendiffraktion von deproteinisiertem Rattenknochen vor und nach der Hydrolyse wies deutlich auf die Anwesenheit von amorphem Calciumphosphat hin. Die Elektronenmikroskopie zeigte kleine Apatitkristalle im Rattenknochen, welche zum Gesamtmineralpool beitragen könnten, der bei der Röntgendiffraktion amorph ist. Die Elektronenmikroskopie zeigte auch Gebiete im Rattenknochenmineral, wo plättchenartige Apatitkristalle eine deutlichec-Achsenorientierung beibehielten, obwohl ihre fibröse Matrix entfernt worden war.
    Notes: Abstract A method is described employing 95% hydrazine which completely deproteinates and slightly dehydrates bone under nearly anhydrous conditions with only moderate heating. This method induced only minor chemical changes and no alterations in structural properties of the mineral phase. Physicochemical data are presented demonstrating that although rat bone crystals more closely resemble synthetic controls made in carbonate-rather than hydroxide-rich media, rat bone apatite cannot be interpreted in terms of known or postulated crystal models in any meaningful fashion. CO 3 2− infrared band assignments made from spectra of whole bone are shown to be in error due to the presence of protein absorption bands. Absorotion of HPO 4 2− was observed in infrared spectra of young rat bone mineral. Detailed X-ray diffraction comparisons of deproteinated rat bone before and after hydrolysis clearly demonstrated the presence of amorphous calcium phosphate. Electron microscopy indicated that very small apatite crystals were present in rat bone which might also contribute to the overall mineral pool amorphous to X-ray diffraction. Electron microscopy also showed domains in rat bone mineral where plate-like apatite crystals maintained a netc-axis orientation despite the removal of their fibrous matrix.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Materials research innovations 3 (2000), S. 313-323 
    ISSN: 1433-075X
    Keywords: Keywords Glass ; Cell cycle ; Genes ; Bone ; Bioactive materials ; Osteogenesis ; Prostheses ; Omplants ; Ageing ; Osteoblasts
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract  Many of the present generation biomaterials are still based upon the early concept that implantable materials should be bioinert and therefore designed to evoke minimal tissue response, if none. However, a growing body of clinical data demonstrates that the long survivability of these materials is hampered by high rates of failure, which is primarily attributed to interfacial instability. It has therefore become understood that this approach is not optimal. Modern approaches implicate the use of biomaterials that can actively interact with tissues and induce their intrinsic repair and regenerative potential. This involves control over the cell cycle, the molecular framework that controls cell proliferation and differentiation. Class A bioactive glass-ceramic materials were the first materials shown to endorse these properties and, depending upon the rate of resorption and release of ions, can create chemical gradients with specific biological actions over cells and tissues. Optimising this bioactive regenerative capacity of Bioactive glass-ceramics offers great hope for producing biomaterials that can stimulate growth, repair, and regeneration of any human tissue.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 13 (1973), S. 73-82 
    ISSN: 1432-0827
    Keywords: Bone ; Apatite ; Hydroxide ; Carbonate ; Infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé L'étude de spectres infra-rouges montre que le minéral osseux de jeune rat et les apatites synthétiques, formés à des pH, force ionique et température physiologiques sont très déficients en ion OH; ces apatites biologiques et synthétiques présentent d'importants défauts internes de maille. En outre, une proportion significative des ions CO3 2- de mineral osseux de rat est structurée de façon lâche dans un environnement amorphe ou superficiel. Les ions carbonate dans l'os chauffé sous vide ou dans les apatites synthétiques formés à pH physiologique paraissent être situés dans des environnements locaux multiples. Le CO3 2- contenu dans ces structures peut se substituer dans des positions PO4 3- et (à un degré moindre) OH−, bien que des variations importantes de ou dans ces positions sont dues à des défauts de maille. Les carbonato-apatites, formés par transformation thermique (600o) de phosphates calciques amorphes et contenant 4–9% de CO3 2-, présentent surtout du CO3 2- dans des environnements OH−. Une recristallisation thermique des apatites biologiques et synthétiques, dans une atmosphère d'air, augmente le contenu en OH− et redispose les positions CO3 2-. Cependant, de telles formations bien cristallisées sont différentes des précurseurs apatitiques.
    Abstract: Zusammenfassung Die Infrarotspektroskopie ergab, daß sowohl natives Rattenknochenmineral als auch synthetische Apatite, welche bei physiologischem pH, Ionenstärke und Temperatur gebildet wurden, an Hydroxydionen stark defizient sind. Es ist ebenfalls ersichtlich, daß diese biologischen und synthetischen Apatitkristalle beträchtliche innere Verzerrungen aufweisen (Gitterdefekte). Weiterhin zeigt ein bedeutender Anteil der CO3 2--Ionen im Rattenknochenmineral eine lockere Struktur in amorpher Umgebung oder an der Oberfläche. In Vakuumerhitzem Knochen oder in synthetischen Apatit (mit physiologischem pH), welches in der Lösung gebildet wurde, scheinen sich die Carbonationen in verschiedenen Umgebungen zu finden. CO3 2- im Inneren dieser Stoffe kann in PO4 3--und (in viel kleineren Mengen) OH−-Positionen ausgetauscht werden, obwohl eine beträchtliche Abweichung von und innerhalb dieser Stellen wahrscheinlich auf Gitterdefekte zurückzuführen ist. Carbonat-Apatite, welche durch die thermische Umwandlung (600°C) von 4–9% CO3 2- enthaltendem amorphem Calciumphosphat gebildet wurden, zeigen in erster Linie in OH−-Umgebung CO3 2-. Die thermische Umkristallisierung von biologischen und synthetischen Apatiten in einer Luftatmosphäre erhöht den OH−-Gehalt und verteilt die CO3 2--Lokalisationen neu. Solche sehr schön kristallisierten Produkte spiegeln jedoch durchaus nicht ihre nativen Apatitvorbilder wider.
    Notes: Abstract Infrared spectral data indicate that both native rat bone mineral and synthetic apatites formed at physiological pH, ionic strength and temperature are extensively deficient in hydroxide ion content; the data also indicate that these biological and synthetic apatites contain considerable internal distortions (lattice defects). In addition, a significant portion of the CO3 2- ions in rat bone mineral is loosely-structured in either an amorphous or surface environment. Carbonate ions in vacuum-heated bone or solution-ripened synthetic (physiological pH) apatites appear to be in multiple local environments. Internal CO3 2- in these materials may be substituted in PO4 3- and (in much lesser amounts) OH− positions, although considerable deviation from or within these sites is probable due to lattice defects. Carbonateapatites produced by thermal conversion (600o) of amorphous calcium phosphates containing 4–9% CO3 2- exhibit CO3 2- mainly in OH− environments. Thermal recrystallization of biological and synthetic apatites in an air atmosphere increases OH− content and reorganizes CO3 2- locales. However, such extremely well-crystallized products are not at all representative of their native apatitic precursors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Keywords: Histomorphometry ; Bone ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 10 (1972), S. 23-30 
    ISSN: 1432-0827
    Keywords: Bone ; Microradiography ; Autoradiography ; Preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé La préparation de coupes fines, plano-parallèles d'os non décalcifié, d'épaisseur connue, pour la réalisation de microradiographies et d'autoradiographies quantitatives est décrite. Pour éviter que des fractures de l'os se produisent, le fragment osseux fixé doit être inclus dans un matériel approprié qui ne doit pas se rétracter. Un minimum de force doit être appliqué à l'échantillon pendant la coupe pour éviter des vibrations. La méthode décrite, utilisant une scie circulaire tournant à faible vitesse, est adéquate. Le polissage final des surfaces du specimen est réalisé sur une machine à polir modifiée. On peut préparer un grand nombre de coupes en relativement peu de temps pour des études statistiques.
    Abstract: Zusammenfassung Die Herstellung von dünnen, parallelgestellten Schnitten von unentkalktem Knochen bekannter Dicke zur quantitativen Auto- und Mikroradiographie wird beschrieben. Der Knochen hat die Tendenz, unter Druck zu brechen. Um diese Schwierigkeit zu überwinden, ist es sehr wichtig, daß die fixierte Knochenprobe genügend vom Einbettungsmaterial durchdrungen wird und daß das Einschlußmittel sich vom Knochenrand weg kontrahiert. Beim Schneiden darf nur ein minimaler Druck auf die Probe ausgeübt werden, damit der Knochen nicht zertrümmert wird. Die beschriebene Methode, bei welcher eine spezielle Einrichtung zum Auftropfen des Schmiermittels den Gebrauch einer langsam rotierenden Kreissäge ermöglichte, erwies sich als günstig. Das schließliche Polieren der Oberflächen der Proben wurde auf einer modifizierten Schleifmaschine ausgeführt. Mit dieser Methode kann eine große Anzahl von Schnitten in relativ kurzer Zeit hergestellt werden; dies ist sehr wichtig, um eine angemessene Anzahl von Proben für statistische Analysen zu erhalten.
    Notes: Abstract The preparation of thin, parallel-sided sections of undecalcified bone of known thickness for quantitative auto- and micro-radiography is described. To overcome the tendency of the bone to fracture when stressed, it is essential that the fixed sample of bone should be adequately penetrated by the embedding material and that the mounting material should not contract away from the edge of the bone. Minimum stress must be applied to the sample when cutting or the bone may be shattered. The method described, using a gravity feed to a low speed circular saw, has been found to be suitable. Final polishing of the surfaces of the specimen was carried out on a modified lapping machine. Large numbers of sections can be prepared in a relatively short time by the method and this is essential to obtain an adequate number of samples for statistical analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...