ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (5)
  • Molecular Diversity Preservation International  (5)
  • 2020-2022  (5)
  • Electrical Engineering, Measurement and Control Technology  (3)
  • Geosciences  (2)
Collection
  • Articles  (5)
Years
Year
  • 1
    Publication Date: 2020-04-22
    Description: The purpose of the present investigation was to examine the acute effects of whole body vibration (WBV) on isometric mid-thigh pull force–time curve (FTC) characteristics. Eleven recreationally trained subjects were randomly assigned to three treatment conditions: sham no vibration protocol (T1), vibration protocol 30 Hz 2–4 mm amplitude (T2), and vibration protocol 30 Hz 2–4 mm (T3). After completing a standardized warm-up, the subject stood on a vibration platform with the knee at a 120° angle and performed one of the three interventions. Each treatment condition required the subject to stand on the platform for thirty-second treatments, each separated by thirty seconds of recovery. Five minutes after the completion of the treatment conditions, the subjects performed the isometric mid-thigh pull. All FTCs were analyzed with standardized procedures for peak force (PF) and peak rate of force development (PRFD). A 1 × 3 repeated measures analysis of variance (ANOVA) was used to compare the three treatments. Additionally, coefficients of variance (CV), as well as intraclass and interclass correlations, were performed. There were no significant differences (p 〉 0.05) for any of the FTC analyses performed in this investigation. The CV and the 95% confidence interval (CI) indicate that the WBV protocol resulted in trivial changes in PF and beneficial changes in PRFD. A 30 Hz 2–4 mm amplitude WBV does not result in a significant increase in isometric mid-thigh pull performance.
    Electronic ISSN: 2571-631X
    Topics: Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2020-05-15
    Description: Reproducible preparation of lithium tetraborate fused beads for XRF analysis of glass and mineral samples is of paramount importance for analytical repeatability. However, as with all glass melting processes, losses due to volatilisation must be taken into account and their effects are not negligible. Here the effects of fused bead melting time have been studied for four Certified Reference Materials (CRM’s: three feldspars, one silicate glass), in terms of their effects on analytical variability and volatilisation losses arising from fused bead preparation. At melting temperatures of 1065 °C, and for feldspar samples, fused bead melting times shorter than approximately 25 min generally gave rise to a greater deviation of the XRF-analysed composition from the certified composition. This variation might be due to incomplete fusion and/or fused bead inhomogeneity but further research is needed. In contrast, the shortest fused bead melting time for the silicate glass CRM gave an XRF-analysed composition closer to the certified values than longer melting times. This may suggest a faster rate of glass-in-glass dissolution and homogenization during fused bead preparation. For all samples, longer melting times gave rise to greater volatilisation losses (including sulphates and halides) during fusion. This was demonstrated by a linear relationship between SO3 mass loss and time1/2, as predicted by a simple diffusion-based model. Iodine volatilisation displays a more complex relationship, suggestive of diffusion plus additional mechanisms. This conclusion may have implications for vitrification of iodine-bearing radioactive wastes. Our research demonstrates that the nature of the sample material impacts on the most appropriate fusion times. For feldspars no less than ~25 min and no more than ~60 min of fusion at 1065 °C, using Li2B4O7 as the fusion medium and in the context of feldspar samples and the automatic fusion equipment used here, strikes an acceptable (albeit non-ideal) balance between the competing factors of fused bead quality, analytical consistency and mitigating volatilisation losses. Conversely, for the silicate glass sample, shorter fusion times of less than ~30 min under the same conditions provided more accurate analyses whilst limiting volatile losses.
    Electronic ISSN: 2075-163X
    Topics: Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2020-10-20
    Description: Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2020-11-20
    Description: We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015 protons/cm2, (1.43±0.14) × 1016 neutrons/cm2, and (6.5±1.4) × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2/(p μm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2/(n μm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2/(π μm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.
    Electronic ISSN: 1424-8220
    Topics: Chemistry and Pharmacology , Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2021-08-25
    Description: Diatoms, a common siliceous alga, are effective paleoclimate and pollution indicators. They have been used in northern, eastern, and southern Africa as such because of well-documented ecologies of many taxa. In southwestern Africa, however, the country of Angola lacks similar modern assemblage studies. To close this gap, modern diatoms were sampled across four water bodies on the Humpata Plateau in southwestern Angola in the dry season of July 2019, with in-situ measurements of pH, conductivity, and total dissolved solids and laboratory analysis of cations and anions. This research concludes that bedrock determines local hydrochemistry. In addition, this exploratory study finds that diatoms in southwestern Angola can infer relative conductivities and trophic levels, but limited data hinder interpretations of diatom ecological preferences of pH, temperature, alkalinity, ions, and pollution, requiring further analyses. Such research is beneficial for both African diatomists interested in using accurate transfer functions across Africa to reconstruct paleoclimates as well as local communities and hydrologists interested in understanding water chemistry and pollution, given that these studied sites are vital water resources for local communities on the Humpata Plateau.
    Electronic ISSN: 2076-3263
    Topics: Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...