Publication Date:
2017-08-08
Description:
An automated analytical system was developed for measuring the oxidative potential (OP) with the dithiothreitol (DTT) assay of filter extracts that include both water-soluble and water-insoluble (solid) aerosol species. Three approaches for measuring total oxidative potential were compared. These include using methanol as the solvent with (1) and without (2) filtering the extract, followed by removing the solvent and reconstituting with water, and (3) extraction in pure water and performing the OP analysis in the extraction vial with the filter. The water extraction method (the third approach, with filter remaining in the vial) generally yielded the highest DTT responses with better precision (coefficient of variation of 1–5 %) and was correlated with a greater number of other aerosol components. Because no organic solvents were used, which must be mostly eliminated prior to DTT analysis, it was easiest to automate by modifying an automated analytical system for measuring water-soluble OP developed by Fang et al. (2015). Therefore, the third method was applied to the field study for the determination of total OP. Daily 23 h filter samples were collected simultaneously at a roadside (RS) and a representative urban (Georgia Tech, GT) site for two 1-month study periods, and both water-soluble (OPWS-DTT) and total (OPTotal-DTT) OP were measured. Using PM2. 5 (aerodynamic diameter
Print ISSN:
1867-1381
Electronic ISSN:
1867-8548
Topics:
Geosciences
Permalink