This article describes the method, based on the kinetics of enzyme reaction, for calculating treatment rates for wastewater effluents of varied concentrations in mixing aeration tanks and continuous flow aeration tanks. Using this method would make it possible to optimize the parameters of the biological treatment of wastewater. In addition, the authors illustrate that partitioning of the aeration space of the mixing aeration tank in a separate KU-200 compact installation, which is intended for wastewater treatment from small sources, would make it possible to increase its efficiency by a factor of 1.8.