ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley-Blackwell  (24)
  • Springer Nature  (8)
  • American Institute of Physics  (2)
  • Amsterdam [u.a.] : Elsevier  (1)
  • 2020-2021
  • 1985-1989  (25)
  • 1965-1969  (4)
  • 1960-1964  (6)
Collection
Language
Years
Year
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 342-345 
    ISSN: 0935-6304
    Keywords: Retention relationships ; General equation ; Iterative procedure ; Logarithmic and linear indices ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 592-594 
    ISSN: 0935-6304
    Keywords: Dimensionless volume ; Approximate functions ; Exact relationship ; Preparative chromatography ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 25 (1987), S. 817-827 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The effect of high-energy ion implantation of oxygen into a thin film of poly(ethylene terephthalate) (PET) was studied by Fourier transform infrared spectroscopy and differential scanning calorimetry (DSC). Mylar samples 13 μm thick were implanted with 6-MeV oxygen ions at fluences ranging from 5 × 1012 to 2 × 1014 ions/cm2. The DSC data showed a substantial loss of crystallinity, even at the lowest fluence, which extended deeper into the polymer film than the predicted range for oxygen deceleration in PET. Solubility measurements indicated the presence of cross-linking, especially at the highest fluence, but bands due to cross-linking could not be detected in the infrared. The trans/gauche ratio for the glycol group conformation was measured by a pair of conformationally sensitive infrared bands. Surprisingly, the conformation of the glycol segments did not change appreciably with increasing fluence, although crystallinity decreased and degree of cross-linking increased. The implications these results have on possible mechanisms of chemical and physical alterations of the polymer structure by ion implantation are discussed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 26 (1988), S. 1457-1467 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Poly(vinylidene fluoride) films were implanted with high-energy (up to 6 MeV) He, C, O, and Ni ions and characterized using DSC, FTIR, and solubility measurements. None of the ions were energetic enough to penetrate the polymer film completely. The effects of ion energy, fluence, and ion type were studied individually. The implantation process lowered the crystallinity, induced crosslinking, and produced carbonyl groups on the polymer. The ion energy (in the range 0.4-4.5 MeV for He ions) had the most drastic effect, the radiation damage was found to increase with decreasing energy. The sample implanted with 0.4 MeV He ions lost 81% of its initial crystallinity and was only 24% soluble, even though the incident ions have a range of only 2.7 μm in this case. The other samples retained most of their initial crystallinity but still were substantially cross-linked. The results can be qualitatively explained by assuming that hydrogen free radicals, produced during implantation, can diffuse throughout the sample and react, resulting in crystallinity and solubility losses beyond the ion deceleration region.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 38 (1989), S. 557-569 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Solubility and diffusivity measurements of a probe gas (CO2), which has an inherently low solubility in the polymer, have been used to characterize residual porosity in polymeric latex films. Sorption isotherms resembling those of a glassy polymer were obtained, even though the glass transition temperature of the polymer was 1°C, about 30°C below the experimental temperature. Solvent cast films of the same polymer exhibited much lower solubilities, and followed the expected Henry's law behavior. CO2 solubility and diffusivity were found to decrease with aging time for the latex films, but did not quite reach the values of the solvent cast films, even after 75 days at room temperature. The sorption data could be described by the dual-mode sorption model, which is commonly employed in the analysis of glassy polymer sorption isotherms. Estimates of the amount of porosity were made from the sorption data, and values ranging from 0.6-0.03% were obtained for latex films aged from 62 h to 75 days, respectively. Our results suggest that permeability differences noted by others for latex and solvent cast films of the same polymer are due to the substantial solubility differences for low-solubility penetrants in these two types of films.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 58 (1986), S. 62-63 
    ISSN: 0009-286X
    Keywords: Fluiddynamik ; Stoffübergang ; hochviskose Gemische ; Siebboden ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 59 (1987), S. 746-747 
    ISSN: 0009-286X
    Keywords: Fluiddynamik ; Stoffübergang ; Newtonsche und nicht-Newtonsche Gemische ; Siebboden ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 0009-286X
    Keywords: Dispergieren ; Dreiphasenströmung ; Kompaktreaktor ; Oberflächenbeschaffenheit ; Schlaufenreaktor ; Suspension ; Turbulenzintensität ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 0170-2041
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Eine einfache Synthese von substituierten Perhydro-1,3-thiazin-4-onen und 2-Thioxoperhydro-4-pyrimidinonenDie basisch katalysierte Cyclisierung der N-Propenoylthioharnstoffe 3 liefert je nach den Reaktionsbedingungen entweder 2,6-disubstituierte 2,3,5,6-Tetrahydro-4H-1,3-thiazin-4-one 4 oder 1,6-disubstituierte 2-Thiouracile 5. Unter denselben Reaktionsbedingungen können die Verbindungen 5 durch eine Art Dimroth-Umlagerung aus den 1,3-Thiazin-4-onen 4 erhalten werden.
    Notes: Depending on the reaction conditions either 2,6-disubstituted 2,3,5,6-tetrahydro-4H-1,3-thiazin-4-ones 4 or 1,6-disubstituted 2-thiouracils 5 are readily prepared by base-catalyzed cyclization of N-propenoylthioureas 3. Compounds 5 could also be obtained by Dimroth-type rearrangement of 1,3-thiazin-4-ones 4 under the same reaction conditions.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Acta Polymerica 38 (1987), S. 443-446 
    ISSN: 0323-7648
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Infrarotspektren von Poly(methylmethacrylat)-Probenn die mit verschiedenen lumineszierenden Substanzen dotiert wurden, weisen außer beim β-Naphthol keine wesentlichen Änderungen der Lage und Intensität der Absorptionsbanden auf. Daher wird angenommen, daß zwischen den meisten Dotierungsmitteln und PMMA keine Wechselwirkung besteht, während beim β-Naphthol zwischen benachbarten Molekülen in der Polymermatrix Wasserstoffbindungen auftreten.
    Notes: The infrared spectra of poly(methyl methacrylate) samples doped with different luminescent materials show no drastic changes in the position and intensity of the absorption bands, except in case of β-naphthol. From this it is supposed that there is no interaction between the dopant and PMMA with most of the investigated materials, while with β-naphthol hydrogen bonding between adjacent molecules in the polymer matrix is observed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...