ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • American Society of Hematology  (4)
  • 2020-2022  (4)
  • 2005-2009
  • 1960-1964
  • 1925-1929
  • 2020  (4)
  • 1
    Publikationsdatum: 2020-06-11
    Beschreibung: Megakaryoblastic leukemia 1 (MKL1) promotes the regulation of essential cell processes, including actin cytoskeletal dynamics, by coactivating serum response factor. Recently, the first human with MKL1 deficiency, leading to a novel primary immunodeficiency, was identified. We report a second family with 2 siblings with a homozygous frameshift mutation in MKL1. The index case died as an infant from progressive and severe pneumonia caused by Pseudomonas aeruginosa and poor wound healing. The younger sibling was preemptively transplanted shortly after birth. The immunodeficiency was marked by a pronounced actin polymerization defect and a strongly reduced motility and chemotactic response by MKL1-deficient neutrophils. In addition to the lack of MKL1, subsequent proteomic and transcriptomic analyses of patient neutrophils revealed actin and several actin-related proteins to be downregulated, confirming a role for MKL1 as a transcriptional coregulator. Degranulation was enhanced upon suboptimal neutrophil activation, whereas production of reactive oxygen species was normal. Neutrophil adhesion was intact but without proper spreading. The latter could explain the observed failure in firm adherence and transendothelial migration under flow conditions. No apparent defect in phagocytosis or bacterial killing was found. Also, monocyte-derived macrophages showed intact phagocytosis, and lymphocyte counts and proliferative capacity were normal. Nonhematopoietic primary fibroblasts demonstrated defective differentiation into myofibroblasts but normal migration and F-actin content, most likely as a result of compensatory mechanisms of MKL2, which is not expressed in neutrophils. Our findings extend current insight into the severe immune dysfunction in MKL1 deficiency, with cytoskeletal dysfunction and defective extravasation of neutrophils as the most prominent features.
    Print ISSN: 0006-4971
    Digitale ISSN: 1528-0020
    Thema: Biologie , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2020-02-27
    Beschreibung: Although thrombin is a key enzyme in the coagulation cascade and is required for both normal hemostasis and pathologic thrombogenesis, it also participates in its own negative feedback via activation of protein C, which downregulates thrombin generation by enzymatically inactivating factors Va and VIIIa. Our group and others have previously shown that thrombin’s procoagulant and anticoagulant activities can be effectively disassociated to varying extents through site-directed mutagenesis. The thrombin mutant W215A/E217A (WE thrombin) has been one of the best characterized constructs with selective activity toward protein C. Although animal studies have demonstrated that WE thrombin acts as an anticoagulant through activated protein C (APC) generation, the observed limited systemic anticoagulation does not fully explain the antithrombotic potency of this or other thrombin mutants. AB002 (E-WE thrombin) is an investigational protein C activator thrombin analog in phase 2 clinical development (clinicaltrials.gov NCT03963895). Here, we demonstrate that this molecule is a potent enzyme that is able to rapidly interrupt arterial-type thrombus propagation at exceedingly low doses (
    Print ISSN: 0006-4971
    Digitale ISSN: 1528-0020
    Thema: Biologie , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Publikationsdatum: 2020-11-19
    Print ISSN: 0006-4971
    Digitale ISSN: 1528-0020
    Thema: Biologie , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2020-11-05
    Beschreibung: Background: End stage renal disease (ESRD) patients on chronic hemodialysis (HD) repeatedly have their blood exposed to artificial surfaces within the hemodialysis circuit, which triggers contact system-initiated coagulation. Clot formation within the HD circuit results in blood loss, decreased HD efficiency, and device circuit failure. Heparin reduces circuit clotting but it is not tolerated by all patients. Mounting experimental data suggest that contact system inhibition is antithrombotic without significantly compromising hemostasis. AB023 is a unique recombinant anti-factor (F) XI antibody that interferes with the interactions of FXI and FXII without inhibiting FXI activation by thrombin or the activation of FIX by activated FXI. This study evaluated the safety, tolerability, pharmacokinetics, and preliminary efficacy of AB023 in patients with ESRD on chronic HD. Methods: In this phase 2, randomized, double-blind, placebo-controlled, single-administration study, AB023 (0.25 or 0.5 mg/kg) or placebo was injected into the HD circuit of 24 ESRD patients at the start of heparin-free HD (NCT03612856). All patients underwent three pre-dose HD procedures and four monitored post-dose HD sessions. In total, the study encompassed 168 individual HD sessions, 72 of which occurred pre-dose and 96 of which occurred post-dose. Safety parameters, including time to hemostasis at HD access site, prothrombin time, physical examinations, vital signs, electrocardiograms, clinical chemistry, immunogenicity and other adverse events (AEs), were recorded. Clotting within the hemodialyzer circuit was assessed using a visual clotting scale by investigators who were blinded to treatment. The frequency of circuit clot obstructions requiring dialyzer exchange was also recorded. Pharmacokinetic and pharmacodynamic parameters, including activated partial thromboplastin times, were also assessed. The study was approved by an ethics review board and all subjects provided written informed consent. Results: AB023 demonstrated a favorable safety profile in ESRD patients. No drug-related AEs were noted. Clinically relevant bleeding did not occur in any patient, and the time to hemostasis at the HD access site was unchanged after AB023 administration. As expected, the aPTT was prolonged after AB023 administration, reaching saturation at both dose levels (about 2-fold prolongation) immediately after dosing, and remaining prolonged for up to 9 days with the high dose. Compared with pretreatment, the frequency of occlusive events requiring circuit exchange decreased by 68% and 50% in subjects given the 0.25 and 0.5 mg/kg AB023 respectively, while the number of occlusive events was numerically unchanged in the placebo arm. Likewise, the number of saline flushes required to maintain circuit patency decreased by 44% and 85%, and the incidence of high-grade clotting in the hemodialyzer as assessed by visual scoring decreased by 15% and 43% on day 1, 8% and 35% by day 3, and 0% and 19% by day 5 in the 0.25 and 0.5 mg/kg cohorts, respectively. Conclusions: Anticoagulation with AB023 was well-tolerated and reduced clot formation within the HD circuit of ESRD patients. These findings suggest that inhibiting contact system activation could reduce medical device-initiated blood clot formation in patients. Disclosures Lorentz: Aronora, Inc.: Current Employment. Verbout:Aronora, Inc.: Current Employment. Shatzel:Aronora, Inc.: Consultancy. Wallisch:Aronora, Inc.: Current Employment. Markway:Aronora, Inc.: Current Employment. Tucker:Aronora, Inc.: Current Employment. Gruber:Aronora, Inc.: Current Employment, Current equity holder in private company.
    Print ISSN: 0006-4971
    Digitale ISSN: 1528-0020
    Thema: Biologie , Medizin
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...