ISSN:
1089-7674
Source:
AIP Digital Archive
Topics:
Physics
Notes:
The effect of a prepulse current on the behavior of wire array Z pinches is investigated. The experiments were performed on the MAGPIE generator (1 MA peak current at 240 ns) [I. Mitchell, J. M. Bayley, J. P. Chittenden et al., Rev. Sci. Instrum. 67, 1533 (1996)]. A linear ramp current, ∼500-ns long, was used as a prepulse. The array consisted of 32 15-μm aluminum wires, 23-mm long arranged in a 16-mm diameter circle. With a prepulse of 1 kA/wire, a low density precursor plasma column (ne∼2×1017 cm−3) is formed on the array axis before the start of the main current. Later, the soft x-ray emission shows the growth of an m=1 helical instability in the precursor plasma, which indicates the presence of a current. Without a prepulse current, the precursor plasma on axis is uniform and does not show any instability. The x-ray pulse at stagnation on axis is at least 30 times smaller with a prepulse current than without. © 2002 American Institute of Physics.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1063/1.1417512
Permalink