ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Meteorological Society  (1)
  • Blackwell Science Ltd.  (1)
  • Copernicus
  • International Union of Crystallography
  • 2000-2004  (3)
  • 2002  (3)
  • 1
    ISSN: 1365-2958
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology , Medicine
    Notes: Streptococcus parasanguis is a primary colonizer of the tooth surface and plays a pivotal role in the formation of dental plaque. The fimbriae of S. parasanguis are important in mediating adhesion to saliva-coated hydroxylapatite (SHA), an in vitro tooth adhesion model. The Fap1 adhesin has been identified as the major fimbrial subunit, and recent studies suggest that Fap1 is a glycoprotein. Monosaccharide analysis of Fap1 purified from the culture supernatant of S. parasanguis indicated the presence of rhamnose, glucose, galactose, N-acetylglucosamine and N-acetylgalactosamine. A glycopeptide moiety was isolated from a pronase digest of Fap1 and purified by immunoaffinity chromatography. The monosaccharide composition of the purified glycopeptide was similar to that of the intact molecule. The functionality of the glycan moiety was determined using monoclonal antibodies (MAbs) specific for the intact Fap1 glycoprotein. These antibodies were grouped into two categories based on their ability to block adhesion of S. parasanguis to SHA and their corresponding specificity for either protein or glycan epitopes of the Fap1 protein. ‘Non-blocking’ MAb epitopes were mapped to unique protein sequences in the N-terminus of the Fap1 protein using non-glycosylated recombinant Fap1 proteins (rFap1 and drFap1) expressed in Escherichia coli. In contrast, the ‘blocking’ antibodies did not bind to the recombinant Fap1 proteins, and were effectively competed by the binding to the purified glycopeptide. These data suggest that the ‘blocking’ antibodies are specific for the glycan moiety and that the adhesion of S. parasanguis is mediated by sugar residues associated with Fap1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2002-03-01
    Print ISSN: 0894-8755
    Electronic ISSN: 1520-0442
    Topics: Geography , Geosciences , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2002-07-18
    Description: The International Union of Crystallography (IUCr) Commission on Powder Diffraction (CPD) has sponsored a round robin on the determination of quantitative phase abundance from diffraction data. The aims of the round robin have been detailed by Madsenet al.[J. Appl. Cryst.(2001),34, 409–426]. In summary, they were (i) to document the methods and strategies commonly employed in quantitative phases analysis (QPA), especially those involving powder diffraction, (ii) to assess levels of accuracy, precision and lower limits of detection, (iii) to identify specific problem areas and develop practical solutions, (iv) to formulate recommended procedures for QPA using diffraction data, and (v) to create a standard set of samples for future reference. The first paper (Madsenet al., 2001) covered the results of sample 1 (a simple three-phase mixture of corundum, fluorite and zincite). The remaining samples used in the round robin covered a wide range of analytical complexity, and presented a series of different problems to the analysts. These problems included preferred orientation (sample 2), the analysis of amorphous content (sample 3), microabsorption (sample 4), complex synthetic and natural mineral suites, along with pharmaceutical mixtures with and without an amorphous component. This paper forms the second part of the round-robin study and reports the results of samples 2 (corundum, fluorite, zincite, brucite), 3 (corundum, fluorite, zincite, silica flour) and 4 (corundum, magnetite, zircon), synthetic bauxite, natural granodiorite and the synthetic pharmaceutical mixtures (mannitol, nizatidine, valine, sucrose, starch). The outcomes of this second part of the round robin support the findings of the initial study. The presence of increased analytical problems within these samples has only served to exacerbate the difficulties experienced by many operators with the sample 1 suite. The major difficulties are caused by lack of operator expertise, which becomes more apparent with these more complex samples. Some of these samples also introduced the requirement for skill and judgement in sample preparation techniques. This second part of the round robin concluded that the greatest physical obstacle to accurate QPA for X-ray based methods is the presence of absorption contrast between phases (microabsorption), which may prove to be insurmountable in some circumstances.
    Print ISSN: 0021-8898
    Electronic ISSN: 1600-5767
    Topics: Geosciences , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...