    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 253-258 
    ISSN: 0935-6304
    Keywords: Comprehensive gas chromatography ; cryogenic modulation ; semi-volatile aromatics ; thermal sweeper ; peak widths ; peak asymmetries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The two current technologies for achieving comprehensive gas chromatography (GC×GC) - the thermal sweeper and the cryogenic modulator - are compared in an interlaboratory study using a multicomponent semi-volatile aromatic compound sample. The same column set (phases, film thickness, dimensions of columns) and conditions of oven temperature program were used. Carrier gas flow settings however were different for the data reported here. The thermal sweeper has a longer overall length due to the extra ca. 30 cm length of narrow bore tubing used for the modulator/accumulator section. Data reveal that the two methods behave in an analogous manner in respect of delivering GC×GC results, with key peak parameters of peak widths and symmetry measures showing good correlation. Retention time dissimilarity on the first dimension columns in the two systems arises from different flow rates used, however the second column retention is similar, and this is due to the resulting different elution temperatures that peaks elute on the first dimension in each system. Overall, the two approaches to GC×GC appear to produce equivalent results within the scope of the application studied. Each system does have its experimental limitations; the thermal sweeper has what may be called a ‘thick film effect’, where at high temperature it can be difficult to sufficiently trap the migrating bands in the accumulator column, and the pulsing of solutes in the cryogenic system may suffer from a ‘thick wall effect’ if a column with too thick a wall dimension is used at low oven temperature.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 245-252 
    ISSN: 0935-6304
    Keywords: LMCS ; cryogenic modulation ; comprehensive gas chromatography ; GC×GC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Comprehensive gas chromatography is the realization of true continuous multidimensional (dual column) gas chromatography. The key requirement in the comprehensive GC experiment is that the second dimension analysis is completed in a rapid time-frame compared to the elution of components in the first dimension, and that the two coupled dimensions represent ‘orthogonal’ analyses towards the analytes to be separated. The former normally necessitates pulsing of contiguous segments of each chromatographic band from the first to the second dimensions. The two dimensions should be in fluid communication. The comprehensive GC×GC experiment passes all the column flow from the first column to the second column, leading to no sample loss, but this also requires a suitable method for time- or zone-compression of the band to be pulsed to the second column. The final pulse should be narrow, and should be delivered to the second column quickly. A simple procedure can achieve this using the cryogenic modulator that has been recently described by this group. The system uses a cryogenic trap which can be moved away from the cooled zone of the column faster than 10 ms. A fast-acting pneumatic ram achieves this performance. The cooled column heats up to the prevailing oven temperature within 10-15 ms. Molecules as volatile as C5 alkanes or small aromatics will be fully retained by the trap within the period of modulation used for GC×GC. The technique is simple to implement and requires no special column connections. Using a gas chromatograph which allows control of external events and can acquire from a detector at 50 Hz or faster, and a timing controller for modulation, the comprehensive result can easily and effectively be achieved.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource