ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy
  • Cell & Developmental Biology
  • Chemical Engineering
  • Physics
  • 1995-1999  (6)
  • 1980-1984
  • 1999  (6)
Collection
Publisher
Years
  • 1995-1999  (6)
  • 1980-1984
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 24-28 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; ECD ; Micro-ECD ; GC detector ; organochlorine pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A new ECD, the HP 6890 Series Micro-ECD, was designed to address inherent deficiencies in classical electron capture detectors (ECD), especially with respect to sensitivity, linearity, dynamic range, and ruggedness. Several novel technologies were incorporated in the totally new design and were refined through practical testing and user feedback. Validation of the micro-ECD performance was accomplished through side-by-side testing of the Micro-ECD with previous ECDs following US EPA Contract Laboratory Program methods for pesticides and PCBs. In addition, extensive interviews were conducted with early users of the Micro-ECD who also had experience with other designs running a variety of ECD methods. The design and resulting performance improvements are described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 29-32 
    ISSN: 0935-6304
    Keywords: Capillary electrochromatography ; electroosmotic flow ; frit ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The formation of bubbles in capillary electrochromatography (CEC) is well documented: possible origins include Joule heating and variations in EOF velocity on passing from the stationary phase through the frit and into the open tube. Methods for the prevention of bubble formation are discussed which are confirmed by experimental results. Using frit lengths varying from 1 mm to 6 mm it is shown how frit length is directly related to the likelihood of bubble formation and how this is affected by applied voltage. It is shown that the change in applied voltage across a capillary affects the formation of bubbles and also that rebonding octadecylsilane (ODS) onto the silica frit after formation of the frit can minimize the formation of bubbles and how this effects the chromatography. A method is also described for increasing the robustness of silica capillaries using a column coupler along with modifications made to conventional capillary electrophoresis equipment to cater for CEC.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Programmed temperature vaporization (PTV) ; GC-AED ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Programmed temperature vaporization injection (PTV) coupled to gas chromatography and atomic emission detector (AED) has been studied for large volume injection of gaseous samples. As examples of the effectiveness of the technique, the results of the analysis of a series of headspace samples of foods such as garlic and onion, and of landfill gases are presented. The volumes of gaseous samples reconcentrated varied from a few milliliters up to liters depending on analyte dilution, through focusing onto a sorbent trap, then rapid liberation into the GC-AED system by programmed thermal desorption. Despite the high carrier gas flow rates associated with direct PTV-GC, AED performance and sensitivity were unaffected. The detailed elemental information obtained from the PTV-GC-AED analyses was confirmed using a PTV coupled to a gas chromatograph with ion trap detector mass spectrometer as detector (PTV-GC-ITD/MS).
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 55-58 
    ISSN: 0935-6304
    Keywords: Micellar electrokinetic capillary chromatography ; sample dissolving solvent ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0935-6304
    Keywords: HPLC ; di(2-ethylhexyl) phthalate ; migration ; foods and food simulants ; PVC cling film ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 22 (1999), S. 159-163 
    ISSN: 0935-6304
    Keywords: Multi-dimensional chromatography ; LC-GC ; AED ; memory effects ; fossil fuel ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Conventional operation of the GC Atomic Emission Detector (AED) system involves backflushing of the microwave induced plasma (MIP) during the elution of small volumes of solvent from the GC column. When performing multi-dimensional, on-line LC-GC-AED, significantly larger solvent volumes are introduced into the system and must subsequently be removed. Thus solvent venting procedures are required and the backflushing of the plasma must be extended to facilitate solvent but not solute removal. This study demonstrates the significance of memory effects imparted upon the MIP of the AED if solvent venting is incomplete. Comparison of conventional GC-AED and multi-dimensional LC-GC-AED is made with respect to a fossil fuel sample.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...