ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Cadmium  (1)
  • Ab initio calculation
  • membrane-attached biofilms
  • 1995-1999  (2)
  • 1996  (2)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 52 (1996), S. 373-386 
    ISSN: 0006-3592
    Keywords: membrane-attached biofilms ; modeling ; extractive membrane bioreactor ; toxic VOC ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This article presents a mathematical model of membrane-attached biofilm (MAB) behavior in a single-tube extractive membrane bioreactor (STEMB). MABs can be used for treatment of wastewaters containing VOCs, treatment of saline wastewaters, and nitrification processes. Extractive membrane bioreactors (EMBs) are employed to prevent the direct contact between a toxic volatile pollutant and the aerated gas by allowing counterdiffusion of substrates; i.e., pollutant diffuses from the tube side into the biofilm, whereas oxygen diffuses from the shell side into the biofilm. This reduces the air stripping problems usually found in conventional bioreactors. In this study, the biodegradation of a toxic VOC (1,2-dichloroethane, DCE) present in a synthetic wastewater has been investigated. An unstructured model is used to describe cell growth and cell decay in the MAB. The model has been verified by comparing model predicted trends with experimental data collected over 5 to 20-day periods, and has subsequently been used to model steady states in biofilm behavior over longer time scales. The model is capable of predicting the correct trends in system variables such as biofilm thickness, DCE flux across the membrane, carbon dioxide evolution, and suspended biomass. Steady states (constant biofilm thickness and DCE flux) are predicted, and factors that affect these steady states, i.e., cell endogeneous decay rate, and biofilm attrition, are investigated. Biofilm attrition does not have a great influence on biofilm behavior at low values of detachment coefficient close to those typically reported in the literature. Steady-state biofilm thickness is found to be an important variable; a thin biofilm results in a high DCE flux across the membrane, but with the penalty of a high loss of DCE via air stripping. The optimal biofilm thickness at steady state can be determined by trading off the decrease in air stripping (desirable) and the decrease in DCE flux (undesirable) which occur simultaneously as the thickness increases. © 1996 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electroanalysis 8 (1996), S. 178-182 
    ISSN: 1040-0397
    Keywords: Mercury microelectrode ; Anodic stripping voltammetry ; Stability constants ; Aminoacids ; Cadmium ; Lead ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Complexation reactions of lead by glutamic acid in KNO3 0.1 M and cadmium by glycine at two ionic strengths (0.1 MKNO3 and 2 × 10-3 M borate buffer) have been used to : 1) compare the stripping response in DCASV (direct current anodic stripping voltammetry) and DPASV (differential pulse anodic stripping voltammetry) at large (hanging mercury drop electrode: HMDE) and small (thin film mercury microelectrode deposited on Pt/lr: μME) electrodes, 2) test classical DeFord-Hume's method with microelectrodes coupled to DCASV and DPASV, and 3) analyze the suitability of both electrodes HMDE and μME coupled to anodic stripping voltammetry to measurements in freshwaters. Indeed due to the mass transport characteristics at microelectrodes, the fraction of a metal which contributes to the current may well be different from that at a conventional size electrode. The obtained results are in all the situations consistent among themselves and in good agreement with literature.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...