ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1995  (2)
Collection
Publisher
Years
  • 1995-1999  (2)
Year
  • 1
    Publication Date: 1995-04-01
    Print ISSN: 1570-145X
    Electronic ISSN: 1570-1468
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Power technology and engineering 29 (1995), S. 242-247 
    ISSN: 1570-1468
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Conclusions 1. Hydraulic investigations of T-shaped forks made it possible to refine the character of head losses in the junction of the tank with the conduits. The use of the dependences obtained in calculating the stability of the regimes of a hydroelectric station just due to a more accurate consideration of the effect of the velocity head in the base of the surge tank permits substantiating a considerable decrease of the critical area of downstream surge tanks. 2. In calculations of the critical area of downstream surge tanks it is necessary to include in total head losses the velocity head in the outlet section of the outflow channel. In this case the value of the critical area decreases. 3. The proposed method of analyzing the stability of HES regimes with the use of the Routh algebraic criterion permits relating the adjustment parameters of the ARS, turbine characteristics, and power system among themselves to the area of the surge tank and solving the problem of stability in the complex. 4. At hydrostations with short outflow pressure conduits it is advisable to take small, up to 10% of the Thoma critical, cross-sectional areas of the surge pipe of a surge tank with an expansion chamber. This makes it possible, on one hand, to reduce the amount of works on the tank and, on the other, to provide stable regimes of the hydrostations while retaining the adjustment parameters of the ARS.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...