ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (47)
  • Aerospace Medicine  (27)
  • INORGANIC AND PHYSICAL CHEMISTRY  (20)
  • Engineering
  • Life and Medical Sciences
  • 2000-2004
  • 1995-1999  (47)
  • 1995  (47)
Collection
Years
  • 2000-2004
  • 1995-1999  (47)
Year
  • 1
    Publication Date: 2013-08-31
    Description: The Evaluation of Oxygen Interactions with Materials 3 (EOIM-3) flight experiment was developed to obtain benchmark atomic oxygen/material reactivity data. The experiment was conducted during Space Shuttle mission 46 (STS-46), which flew July 31 to August 7, 1992. Quantitative interpretation of the materials reactivity measurements requires a complete and accurate definition of the space environment exposure, including the thermal history of the payload, the solar ultraviolet exposure, the atomic oxygen fluence, and any spacecraft outgassing contamination effects. The thermal history of the payload was measured using twelve thermocouple sensors placed behind selected samples and on the EOIM-3 payload structure. The solar ultraviolet exposure history of the EOIM-3 payload was determined by analysis of the as-flown orbit and vehicle attitude combined with daily average solar ultraviolet and vacuum ultraviolet (UV/VUV) fluxes. The atomic oxygen fluence was assessed in three different ways. First, the O-atom fluence was calculated using a program that incorporates the MSIS-86 atmospheric model, the as-flown Space Shuttle trajectory, and solar activity parameters. Second, the oxygen atom fluence was estimated directly from Kapton film erosion. Third, ambient oxygen atom measurements were made using the quadrupole mass spectrometer on the EOIM-3 payload. Our best estimate of the oxygen atom fluence as of this writing is 2.3 +/- 0.3 x 10(exp 20) atoms/sq cm. Finally, results of post-flight X-ray photoelectron spectroscopy (XPS) surface analyses of selected samples indicate low levels of contamination on the payload surface.
    Keywords: INORGANIC AND PHYSICAL CHEMISTRY
    Type: NASA. Langley Research Center, LDEF: 69 Months in Space. Third Post-Retrieval Symposium, Part 3; p 903-916
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-13
    Description: OBJECTIVE--To investigate the alterations in autonomic control of heart rate at high altitude and to test the hypothesis that hypoxaemic stress during exposure to high altitude induces non-linear, periodic heart rate oscillations, similar to those seen in heart failure and the sleep apnoea syndrome. SUBJECTS--11 healthy subjects aged 24-64. MAIN OUTCOME MEASURES--24 hour ambulatory electrocardiogram records obtained at baseline (1524 m) and at 4700 m. Simultaneous heart rate and respiratory dynamics during 2.5 hours of sleep by fast Fourier transform analysis of beat to beat heart rate and of an electrocardiographically derived respiration signal. RESULTS--All subjects had resting hypoxaemia at high altitude, with an average oxyhaemoglobin saturation of 81% (5%). There was no significant change in mean heart rate, but low frequency (0.01-0.05 Hz) spectral power was increased (P 〈 0.01) at high altitude. Time series analysis showed a complex range of non-linear sinus rhythm dynamics. Striking low frequency (0.04-0.06 Hz) heart rate oscillations were observed during sleep in eight subjects at high altitude. Analysis of the electrocardiographically derived respiration signal indicated that these heart rate oscillations correlated with low frequency respiratory oscillations. CONCLUSIONS--These data suggest (a) that increased low frequency power during high altitude exposure is not simply attributable to increased sympathetic modulation of heart rate, but relates to distinctive cardiopulmonary oscillations at approximately 0.05 Hz and (b) that the emergence of periodic heart rate oscillations at high altitude is consistent with an unstable cardiopulmonary control system that may develop on acute exposure to hypoxaemic stress.
    Keywords: Aerospace Medicine
    Type: British heart journal (ISSN 0007-0769); 74; 4; 390-6
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: BACKGROUND AND PURPOSE: Presyncope, characterized by symptoms and signs indicative of imminent syncope, can be aborted in many situations before loss of consciousness occurs. The plasticity of cerebral autoregulation in healthy humans and its behavior during this syncopal prodrome are unclear, although systemic hemodynamic instability has been suggested as a key factor in the precipitation of syncope. Using lower body negative pressure (LBNP) to simulate central hypovolemia, we previously observed falling mean flow velocities (MFVs) with maintained mean arterial blood pressure (MABP). These findings, and recent reports suggesting increased vascular tone within the cerebral vasculature at presyncope, cannot be explained by the classic static cerebral autoregulation curve; neither can they be totally explained by a recent suggestion of a rightward shift in this curve. METHODS: Four male and five female healthy volunteers were exposed to presyncopal LBNP to evaluate their cerebrovascular and cardiovascular responses by use of continuous acquisition of MFV from the right middle cerebral artery with transcranial Doppler sonography, MABP (Finapres), and heart rate (ECG). RESULTS: At presyncope, MFV dropped on average by 27.3 +/- 14% of its baseline value (P 〈 .05), while MABP remained at 2.0 +/- 27% above its baseline level. Estimated cerebrovascular resistance increased during LBNP. The percentage change from baseline to presyncope in MFV and MABP revealed consistent decreases in MFV before MABP. CONCLUSIONS: Increased estimated cerebrovascular resistance, falling MFV, and constant MABP are evidence of an increase in cerebral vascular tone with falling flow, suggesting a downward shift in the cerebral autoregulation curve. Cerebral vessels may have a differential sensitivity to sympathetic drive or more than one type of sympathetic innervation. Future work to induce dynamic changes in MABP during LBNP may help in assessing the plasticity of the cerebral autoregulation mechanism.
    Keywords: Aerospace Medicine
    Type: Stroke; a journal of cerebral circulation (ISSN 0039-2499); Volume 26; 10; 1794-800
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2004-12-03
    Description: Increased sensitivity of end-organ responses to neuroendocrine stimuli as a result of prolonged exposure to the relative inactivity of microgravity has recently been hypothesized. This notion is based on the inverse relationship between circulating norepinephrine and beta-adrenoreceptor sensitivity. The beta-adrenoreceptor activity is reduced in individuals who have elevated plasma norepinephrine as a result of regular exposure to upright posture and physical exercise. In contrast, adrenoreceptor hypersensitivity has been reported in patients with dysautonomias in which circulating catecholamines are absent or reduced. Taken together, these studies and the observation that circulating plasma norepinephrine has been reduced during spaceflight and in groundbased simulations of microgravity prompt the suggestion that adrenoreceptor hypersensitivity may be a consequence of the adaptation to spaceflight. We conducted an experiment designed to measure cardiovascular responses to adrenoreceptor agonists in human subjects before and after prolonged exposure to 6 deg head-down tilt (HDT) to test the hypothesis that adaptation to microgravity increases adrenoreceptor responsiveness, and that this adaptation is associated with reduced levels of circulating norepinephrine.
    Keywords: Aerospace Medicine
    Type: Journal of Gravitational Physiology, Volume 2, No. 1; 66-67
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2013-08-31
    Description: Many routine methods for monitoring of trace amounts of atmospheric organic pollutants consist of several steps. Typical steps are: (1) collection of the air sample; (2) trapping of organics from the sample; (3) extraction of the trapped organics; and (4) identification of the organics in the extract by GC (gas chromatography), HPLC (High Performance Liquid Chromatography), or MS (Mass Spectrometry). These methods are often cumbersome and time consuming. A simple and fast method for monitoring atmospheric organics using an IMS (Ion Mobility Spectrometer) is proposed. This method has a short sampling time and does not require extraction of the organics since the sample is placed directly in the IMS. The purpose of this study was to determine the responses in the IMS to organic 'priority pollutants'. Priority pollutants including representative polycyclic aromatic hydrocarbons (PAHs), phthalates, phenols, chlorinated pesticides, and polychlorinated biphenyls (PCB's) were analyzed in both the positive and negative detection mode at ambient atmospheric pressure. Detection mode and amount detected are presented.
    Keywords: INORGANIC AND PHYSICAL CHEMISTRY
    Type: NASA. Johnson Space Center, Third International Workshop on Ion Mobility Spectrometry; p 209-213
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2013-08-31
    Description: The Evaluation of Oxygen Interactions with Materials 3 (EOIM-3) flight experiment was developed to obtain benchmark atomic oxygen reactivity data and was conducted during Space Transportation System Mission 46 (STS-46), July 31 to August 7, 1992. In this paper, we present an overview of EOIM-3 and the results of the Lyndon B. Johnson Space Center (JSC) materials reactivity and mass spectrometer/carousel experiments. Mass spectrometer calibration methods are discussed briefly, as a prelude to a detailed discussion of the mass spectrometric results produced during STS-46. Mass spectrometric measurements of ambient O-atom flux and fluence are in good agreement with the values calculated using the MSIS-86 model of the thermosphere as well as estimates based on the extent of O-atom reaction with Kapton polyimide. Mass spectrometric measurements of gaseous products formed by O-atom reaction with C(13) labeled Kapton revealed CO, CO2, H2O, NO, and NO2. Finally, by operating the mass spectrometer so as to detect naturally occurring ionospheric species, we characterized the ambient ionosphere at various times during EOIM-3 and detected the gaseous reaction products formed when ambient ions interacted with the C(13) Kapton carousel sector. By direct comparison of the results of on-orbit O-atom exposures with those conducted in ground-based laboratory systems, which provide known O-atom fluences and translational energies, we have demonstrated the strong translational energy dependence of O-atom reactions with a variety of polymers. A 'line-of-centers' reactive scattering model was shown to provide a reasonably accurate description of the translational energy dependence of polymer reactions with O atoms at high atom kinetic energies while a Beckerle-Ceyer model provided an accurate description of O-atom reactivity over a three order-of-magnitude range in translational energy and a four order-of-magnitude range in reaction efficiency. Postflight studies of the polymer samples by x-ray photoelectron spectroscopy and infrared spectroscopy demonstrate that O-atom attack is confined to the near-surface region of the sample, i.e. within 50 to 100 A of the surface.
    Keywords: INORGANIC AND PHYSICAL CHEMISTRY
    Type: NASA. Langley Research Center, LDEF: 69 Months in Space. Third Post-Retrieval Symposium, Part 3; p 869-902
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-13
    Description: This report covers the analysis of passive radiation detectors flown as part of the A0015 Free Flyer Biostack on LDEF (Long Duration Exposure Facility). LET (linear energy transfer) spectra and track density measurements were made with CR-39 and Polycarbonate plastic nuclear track detectors. Measurements of total absorbed dose were carried out using Thermoluminescent Detectors. Thermal and resonance neutron dose equivalents were measured with LiF/CR-39 detectors. High energy neutron and proton dose equivalents were measured with fission foil/CR-39 detectors.
    Keywords: INORGANIC AND PHYSICAL CHEMISTRY
    Type: NASA-CR-196603 , NAS 1.26:196603
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: The bone loss and hypercalciuria induced by immobilization or the decreased gravitational forces of space are well described. Using a model of bedrest immobilization, the ability of a potent aminobisphosphonate, alendronate, to avert hypercalciuria and stone-forming propensity was tested. Sixteen male subjects participated in a randomized, placebo-controlled trial in which they received either 20 mg of alendronate or placebo 2 weeks prior to and during 3 weeks of strict bedrest. Parameters of bone and calcium metabolism and urinary crystallization of stone-forming salts were measured before and at the end of bedrest. In the placebo group, bedrest increased urinary calcium (209 +/- 47 to 267 +/- 60 mg/day, p 〈 0.01) and the saturation of calcium phosphate. Before bedrest, the alendronate group had a significantly lower serum calcium (8.8 +/- 0.4 vs. 9.6 +/- 0.5 mg/dl, p 〈 0.01) and higher serum PTH (62.4 +/- 33.1 vs. 23.1 +/- 7.5 pg/ml, p 〈 0.01) compared with the placebo group. Moreover, the alendronate group had a lower urinary calcium (75 +/- 41 mg/day) and saturation of calcium oxalate and calcium phosphate. These effects of alendronate were sustained during bedrest. Following bedrest in the alendronate group, urinary calcium rose to 121 +/- 50 mg/day, a value less than that in the placebo group before or during bedrest. Similarly, urinary saturation of calcium oxalate and calcium phosphate rose with bedrest in the alendronate-treated patients but remained lower than values obtained in placebo-treated patients before or during bedrest. Alendronate inhibits bone mineral loss and averts the hypercalciuria and increased propensity for the crystallization of stone-forming calcium salts which occurs during 3 weeks of strict bedrest.
    Keywords: Aerospace Medicine
    Type: Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research (ISSN 0884-0431); 10; 4; 655-62
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-13
    Description: Exposure of osteosarcoma cell lines to chronic intermittent strain increases the activity of mechano-sensitive cation (SA-cat) channels. The impact of mechano-transduction on osteoblast function has not been well studied. We analyzed the expression and production of bone matrix proteins in human osteoblast-like osteosarcoma cells, OHS-4, in response to chronic intermittent mechanical strain. The OHS-4 cells exhibit type I collagen production, 1,25-Dihydroxyvitamin D-inducible osteocalcin, and mineralization of the extracellular matrix. The matrix protein message level was determined from total RNA isolated from cells exposed to 1-4 days of chronic intermittent strain. Northern analysis for type I collagen indicated that strain increased collagen message after 48 h. Immunofluorescent labeling of type I collagen demonstrated that secretion was also enhanced with mechanical strain. Osteopontin message levels were increased several-fold by the application of mechanical load in the absence of vitamin D, and the two stimuli together produced an additive effect. Osteocalcin secretion was also increased with cyclic strain. Osteocalcin levels were not detectable in vitamin D-untreated control cells. However, after 4 days of induced load, significant levels of osteocalcin were observed in the medium. With vitamin D present, osteocalcin levels were 4 times higher in the medium of strained cells compared to nonstrained controls. We conclude that mechanical strain of osteoblast-like cells is sufficient to increase the transcription and secretion of matrix proteins via mechano-transduction without hormonal induction.
    Keywords: Aerospace Medicine
    Type: Endocrinology (ISSN 0013-7227); 136; 2; 528-35
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: We investigated the dynamic properties of the human vestibulo-ocular reflex (VOR) during roll head rotations in three human subjects using the magnetic search coil technique. In the first of two experiments, we quantify the behavior of the ocular motor plant in the torsional plane. The subject's eye was mechanically displaced into intorsion, extorsion or abduction, and the dynamic course of return of the eye to its resting position was measured. The mean predominant time constants of return were 210 msec from intorsion, 83 msec from extorsion, and 217 msec from abduction, although there was considerable variability of results from different trials and subjects. In the second experiment, we quantify the efficacy of velocity-to-position integration of the vestibular signal. Position-step stimuli were used to test the torsional or horizontal VOR, being applied with subjects heads erect or supine. After a torsional position-step, the eye drifted back to its resting position, but after a horizontal position-step the eye held its new horizontal position. To interpret these responses we used a simple model of the VOR with parameters of the ocular motor plant set to values determined during Exp 1. The time constant of the velocity-to-position neural integrator was smaller (typically 2 sec) in the torsional plane than in the horizontal plane (〉 20 sec). No disconjugacy of torsional eye movements was observed. Thus, the dynamic properties of the VOR in roll differ significantly from those of the VOR in yaw, reflecting different visual demands placed on this reflex in these two planes.
    Keywords: Aerospace Medicine
    Type: Vision research (ISSN 0042-6989); 35; 5; 679-89
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...