ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1)
  • enzyme purification  (1)
  • Wiley-Blackwell  (2)
  • American Chemical Society (ACS)
  • American Institute of Physics (AIP)
  • Oxford University Press
  • 2005-2009
  • 1990-1994  (2)
  • 1980-1984
  • 1955-1959
  • 1992  (2)
Collection
Publisher
  • Wiley-Blackwell  (2)
  • American Chemical Society (ACS)
  • American Institute of Physics (AIP)
  • Oxford University Press
Years
  • 2005-2009
  • 1990-1994  (2)
  • 1980-1984
  • 1955-1959
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 39 (1992), S. 717-724 
    ISSN: 0006-3592
    Keywords: Chromatography costs ; cost equations ; α-galactosidase ; enzyme purification ; affinity chromatography ; ion-exchange chromatography ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The purification of α-galactosidase from soybean seeds is a five to six-step procedure consisting of cryoprecipitation, acid precipitation and ammonium sulfate fractionation followed by two or three chromatography steps. The procedures, while not optimized, were carried out in a manner that resulted in 414-515-fold purification, as reported previously. The costs of two purification sequences were compared. In the best case, the preparative-scale costs of stationary phase, reagents, and hardware were $790 per million enzyme units, excluding labor. Stationary phase costs predominated over extraction, chromatography reagent, and eluent costs when the stationary phase is replaced after 10-40 cycles of use. However, if stationary phase life exceeds 50-200 cycles, stationary phase costs become similar in magnitude to eluent and reagent costs. Labor costs, which are process-specific and difficult to estimate, exceed all other costs by a factor of 10-50 at a small scale of operation and constitute a major cost, regardless of scale. This case study provides equations and a frame-work for carrying out a first comparison of costs for multistep purification sequences. Column life, throughput, and scale of operation were found to determine not only the magnitude, but also the relative contributions, of the different components that make up purification costs. This analysis shows that there are major opportunities for reducing purification costs through the development of less expensive stationary phases and the implementation of intelligent process control and automation for process scale chromatography.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 717-718 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Chemical weapons use, although prohibited by the 1925 Geneva Protocol, has been reported in several armed conflicts including the Iran/Iraq war. The use of these weapons during this conflict and the concern over possible use of chemical warfare (CW) agents during the Persian Gulf war has heightened international awareness and prompted many nations to pursue with incresed vigour the signature of a new Chemical Weapons Convention. The most recent draft of the Chemical Weapons Convention contains a number of provisions aimed at developing a treaty that will enable nations to ensure compliance by all signatory nations. Compliance monitoring will be required in a number of scenarios, including the verification of alleged use, the storage and destruction of chemical weapons stocks and ensuring that industrial sites are not illegally producing CW agents. It follows from this draft treaty that compliance monitoring will require a high level of sophisticated analytical support to ensure the establishment of an enforceable treaty. The United Nations Conference on Disarmament therefore formed a multi-national Technical Group on Instrumentation to address the analytical challenges confronting signatory nations.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...